Almost ready to push higher power from mains on this thing. Might be able to actually do 1kW or close to it using the caps I've got on there.

I'm using a random 1500:1 CT I pulled from some big VFD or something so it's a 60hz core but seems to work for now. I have the VCO set to swing from around 49khz up to about 73khz or so. That 73khz region is where it wants to run when I put aluminum or copper inside the work coil. With steel or no load it will run around that 63khz region I was setting it to before with the signal generator.

Unless I change this thing around it looks like an issue I'll need to work out is current limiting the no load operation. From 120VAC the no load current would probably be a ton. Tank current is about 300A pk when I have my DC supply maxed at 10A.
PLL Full Bridge Induction Heater Feedback TestBig Rock 3s FPV ExploringDJI O4 Pro w/HEQ Gimbal on Typhon 3s w/Live Rear CamRC FPV From Living Room ARRMA Big RockAnother Plasma Donut CircuitH-Bridge Induction Heater & DRSSTC Driver OCP TestTyphon 3s FPV Wandering AroundQCW SSTC Double Full Bridge First TestBasic Arduino Nano Tesla Coil Interrupter V1 w/ Fiber Optic Link (SSTC/DRSSTC/Bluetooth Audio)Plasma Donut + PWM14Mhz Plasma Flame Build (for Plasma Toroid testing)RC FPV ARRMA Fireteam 4S DJI O4 Pro Tearing Up Snow