Unleash Your PLC Power: Multiple Machines, One Program! @ACCautomation
Unleash Your PLC Power: Multiple Machines, One Program!  @ACCautomation
Uploaded November 2026 | Updated November 2026, 3 hours ago
Free PLC simulator now runs a motor starter, conveyor and tank on one ladder logic program, each 3D machine in its own block of PLC memory.

โšก QUICK ANSWER
PLC simulator multi scene support means one ladder program can drive several 3D machines at the same time, where previously it was one scene only: a motor starter, or a conveyor, or a tank. From version 121 that restriction is gone, and the simulator gives each machine its own block of PLC memory so the machines cannot fight each other over addresses. That separation is necessary because every scene thinks it is the only one. Open the motor starter on its own and it uses X1 for start, X2 for stop and X3 for the overload contact, and so does every other scene, which is why each one is given an address offset when more than one is connected. The full walkthrough is in the blog post.

๐Ÿ“– FULL WALKTHROUGH + EXAMPLES
accautomation.ca/run-two-3d-machines-at-once-multi-scene-plc-simulator

โ–ถ RUN IT NOW, FREE IN YOUR BROWSER
accautomation.ca/simulator

๐Ÿ“š WHAT YOU'LL LEARN
โœ… Connect several 3D machines to a single ladder program at the same time
โœ… Understand why every scene uses X1, X2 and X3 when opened on its own
โœ… Let the simulator give each machine its own block of PLC memory
โœ… Test an integrated setup instead of one device at a time
โœ… Plan which machines to combine before you write the logic

โ“ FREQUENTLY ASKED
Q: Why does each machine need its own block of PLC memory?
A: Because every scene is written as though it is the only one connected. Without separate memory blocks, two machines would both claim X1 and fight over the same addresses.

Q: What were the limits before this?
A: One 3D scene per program. A motor starter, or a conveyor, or a tank, but never two at once.

Q: Which machines can be combined?
A: It depends on the I/O each one needs, since the total is capped. A small starter and panel leave plenty of room; a palletizer takes most of it on its own.

Q: Does anything not get offset?
A: Yes. Analog addresses and anything driven over Modbus from a real PLC stay exactly where the scene guide lists them.
๐Ÿ‘‰ Full walkthrough and examples: accautomation.ca/run-two-3d-machines-at-once-multi-scene-plc-simulator

๐Ÿ”— MORE RESOURCES
โ–ถ Free PLC Simulator: accautomation.ca/simulator
โ–ถ Analog and Modbus offset exceptions: youtube.com/shorts/Ue0OkUsc2xo
โ–ถ Address limits and offsets in your own programs: youtube.com/shorts/bCcMm3Wcwmo
โ–ถ Series: accautomation.ca/series
โ–ถ PLC Beginners Guide: accautomation.ca/programming/plc-beginners-guide
โ–ถ Free eBooks: accautomation.ca (subscribe for download)

๐Ÿ›’ RECOMMENDED HARDWARE
โ–ถ Shop: automationdirect.com
โ–ถ Parts Guide: accautomation.ca/purchase-find-parts

๐Ÿ’ฌ Which two machines would you run together? Drop a comment below.

๐Ÿ”” New tutorials every Monday โ€” Subscribe and hit the bell!

#PLC #LadderLogic #IndustrialAutomation #PLCProgramming #ACCAutomation #PLCSimulator #LearnPLC #PLCTutorial #Shorts

Regards,
Garry
ACC Automation
accautomation.ca
Unleash Your PLC Power: Multiple Machines, One Program!Can AI Program a PLC?  I Tested It Live in the ACC PLC Simulator!Is This the Best Browser PLC Sim? #engineering #techWhen wife brings up the past #husbandwifeHow to Set Up Inputs and Outputs Correctly! #plc #automation #tutorialWhen a 3D Scene and Your Gamepad Fight โ€” the Scene Wins!Setting up the AI Conveyor Program Challenge!PLC Start/Stop: The Seal-In Latch Explained!I/O Allocation Problems: The Real Reason Your System Isnt WorkingWhat is a normally closed contact?Stop Button Test Catches the Hidden Problem! ๐Ÿ›‘ #plcprogramming #automationWhy You Need to Use a Drum Sequencer for Traffic Lights #PLC #automation #coding
ACC Automation: PLC & Industrial Control Learning |

Unleash Your PLC Power: Multiple Machines, One Program!

SHARE TO X SHARE TO REDDIT SHARE TO FACEBOOK WALLPAPER