Uploaded May 2021 | Updated November 2026, 2 hours ago
A measurement session on the Tesla coil arrangement for the cosmic induction generator. The coils are measured individually and in series on an LCR meter, showing only about three microhenry of interaction between the current and potential coils, and Eric notes both hold the same length of wire, following the Colorado Springs practice. The resonant frequency is then found and the half power points located at 70.7 percent, giving a 9 kilocycle bandwidth and a multiplication factor of about 577 with the new loading rings fitted. The session ends with an 8 watt fluorescent tube lit in free space about 11 inches from the loading ring on 10 volts from a signal generator, retuned as it is moved because the capacitance changes with distance.
Chapters
0:00 Measuring the coil inductances
3:06 Current coil against potential coil
7:43 How much the two coils interact
9:13 Same wire length in each end
13:50 Why 70.7 percent
17:16 A more accurate meter, and 577
27:58 Lighting a tube in free space
32:14 Eleven inches away on 10 volts
ericpdollard.com/donate
emediapress.com/product-category/authors-presenters/eric-dollard
emediapress.com
emediapress.com/energytimes
EPD Laboratories, Inc. Recorded 2021-04-06. Posted 2021-05-14.
A measurement session on the Tesla coil arrangement for the cosmic induction generator. The coils are measured individually and in series on an LCR meter, showing only about three microhenry of interaction between the current and potential coils, and Eric notes both hold the same length of wire, following the Colorado Springs practice. The resonant frequency is then found and the half power points located at 70.7 percent, giving a 9 kilocycle bandwidth and a multiplication factor of about 577 with the new loading rings fitted. The session ends with an 8 watt fluorescent tube lit in free space about 11 inches from the loading ring on 10 volts from a signal generator, retuned as it is moved because the capacitance changes with distance.
Chapters
0:00 Measuring the coil inductances
3:06 Current coil against potential coil
7:43 How much the two coils interact
9:13 Same wire length in each end
13:50 Why 70.7 percent
17:16 A more accurate meter, and 577
27:58 Lighting a tube in free space
32:14 Eleven inches away on 10 volts
ericpdollard.com/donate
emediapress.com/product-category/authors-presenters/eric-dollard
emediapress.com
emediapress.com/energytimes
EPD Laboratories, Inc. Recorded 2021-04-06. Posted 2021-05-14.










