I modified my Harbor Freight Dust Collector and installed it in a small outdoor tool closet (Rubbermaid Roughneck) that I already had. I mounted the fan on a 55-gallon drum that acts as a cyclone separator to keep material from clogging the intake screen on the fan. By having the collector outside the shop the noise is reduced, the fine dust the bag filter does not filter is kept out, and it does not take up the original floor space. I use the @Rockler Dust Right system and expandable hose as well as 4-inch PVC for routing. On/Off switch inside, may upgrade to a remote as well at some point.
Answers for two great questions from the comments in regards to air makeup to my shed and exhaust of the tool closet:
• I did not need to worry about makeup, my shop is not airtight and my window a/c has a makeup damper built in.
• I plan to add exhaust ports to the tool shed to help move more air out of it.
Myers Woodshop also has a good video with a similar idea:
youtu.be/2XIMlRE-FjA?si=Nz57bVtdmJ-1xcua
Between the feedback in the comments and the setup on the Myers Woodshop video, I may have a future modification to consider. Instead of using a separate tool closet, I may build an attached closet, fully enclosed, with a MERV 14 or 15 box filter back into the workshop. This would allow makeup back into the shop with less impact on the heating and cooling and less restriction on the discharge of the collector. The noise should still be reduced since it is still separated (and not take up existing floor space). Your thoughts?
I modified my Harbor Freight Dust Collector and installed it in a small outdoor tool closet (Rubbermaid Roughneck) that I already had. I mounted the fan on a 55-gallon drum that acts as a cyclone separator to keep material from clogging the intake screen on the fan. By having the collector outside the shop the noise is reduced, the fine dust the bag filter does not filter is kept out, and it does not take up the original floor space. I use the @Rockler Dust Right system and expandable hose as well as 4-inch PVC for routing. On/Off switch inside, may upgrade to a remote as well at some point.
Answers for two great questions from the comments in regards to air makeup to my shed and exhaust of the tool closet:
• I did not need to worry about makeup, my shop is not airtight and my window a/c has a makeup damper built in.
• I plan to add exhaust ports to the tool shed to help move more air out of it.
Myers Woodshop also has a good video with a similar idea:
youtu.be/2XIMlRE-FjA?si=Nz57bVtdmJ-1xcua
Between the feedback in the comments and the setup on the Myers Woodshop video, I may have a future modification to consider. Instead of using a separate tool closet, I may build an attached closet, fully enclosed, with a MERV 14 or 15 box filter back into the workshop. This would allow makeup back into the shop with less impact on the heating and cooling and less restriction on the discharge of the collector. The noise should still be reduced since it is still separated (and not take up existing floor space). Your thoughts?