Low Frequency Audio Generator Accuracy Check With Line Frequency @OldSchoolElectronics
Low Frequency Audio Generator Accuracy Check With Line Frequency  @OldSchoolElectronics
Uploaded May 2018 | Updated November 2026, 3 hours ago
Here I attempt to use the line frequency to check the low frequency accuracy of an audio generator using the X-Y mode of the oscilloscope. The line frequency sine wave was not clean. I used an old power transformer with a low-voltage secondary to which I connected the the X (horizontal) input of the scope. The audio generator was connected to the Y (vertical input). It seems this test is useful only to a certain point; with increasing frequency the Lissajous figures become difficult to read. If the line frequency has an accuracy of 1% it would vary .6 Hz (for 60 Hz line frequency) or .5 Hz (for 50 Hz line frequency) either way; 59.4 to 60.6 Hz or 49.5 to 50.5 Hz. If the line frequency has an accuracy of .1% it would vary .06 Hz (for 60 Hz line frequency) or .05 (for 50 Hz line frequency); 59.94 to 60.06 Hz or 49.95 to 50.05 Hz. A .05% line frequency accuracy would be even better. I guessed it would probably best to do this test during the hours when the electricity demand is not so high/doesn't fluctuate much.
Low Frequency Audio Generator Accuracy Check With Line FrequencySharp GF9797 No OutputMarantz 2215B Stereo Receiver Repair   Part 2Sharp GF-555 Boombox Power Output TestSherwood 3050 CD-Player   Part 1Heathkit IN-3127 Decade Capacitor Subsitution BoxMarantz 2215B Stereo Receiver Lights   PART 2Sharp GF-9595  Boombox  RMS Power Output TestSharp GF-9595  Boombox Rubber Pulley ReplacementYamaha R5 Stereo Receiver TroubleshootingPioneer TX-606 Vintage Tuner BulbSanyo M4500 Cassette High Frequency Loss & Azimuth Adjustment
Old School |

Low Frequency Audio Generator Accuracy Check With Line Frequency

SHARE TO X SHARE TO REDDIT SHARE TO FACEBOOK WALLPAPER