Uploaded November 2026 | Updated November 2026, 2 hours ago
PLC code written by AI pasted straight into the ACC PLC Simulator, connected to the 3D conveyor scene and run. Cycle one, start to auto stop, unedited.
โก QUICK ANSWER
PLC conveyor code generated by an AI completed its first cycle correctly with no edits. Pressing start sent the box forward, the right hand proximity sensor triggered the direction change, the box travelled back, the left hand sensor was reached and the motor stopped on its own. That is the full auto reverse and auto stop sequence working on the first attempt in the ACC PLC Simulator against the 3D conveyor scene. Later cycles and the hand verification that followed are in the written test, including the one edge case that only showed up on inspection.
๐ FULL STEP-BY-STEP + DOWNLOADS (project file, wiring diagrams, screenshots)
accautomation.ca/can-ai-program-a-plc-i-tested-it-live-in-the-acc-plc-simulator
๐ WHAT YOU'LL LEARN
โ Paste Structured Text into the ACC PLC Simulator and connect the 3D conveyor scene
โ Watch a full auto reverse cycle run from start press to motor stop
โ Confirm a direction change is triggered by the end of travel sensor, not a timer
โ Verify auto stop happens at the opposite sensor without an operator command
โ Judge AI generated PLC code on observed behavior rather than on how it reads
โ FREQUENTLY ASKED
Q: Did the AI generated code run without any edits?
A: Yes. It was pasted in as received and the first cycle completed correctly, which is still not the same as being verified.
Q: What triggers the reverse, and what triggers the stop?
A: The right hand proximity sensor reverses direction at the end of forward travel. The left hand sensor ends the cycle and stops the motor.
Q: Is a passing cycle enough to accept the program?
A: No. Correct behavior on a normal run says nothing about scan order or first scan initialization, both of which needed checking by hand.
๐ Full step-by-step, code and wiring diagrams: accautomation.ca/can-ai-program-a-plc-i-tested-it-live-in-the-acc-plc-simulator
๐ MORE RESOURCES
โถ Series: accautomation.ca/series
โถ Free PLC Simulator: accautomation.ca/simulator
โถ PLC Beginners Guide: accautomation.ca/programming/plc-beginners-guide
โถ Free eBooks: accautomation.ca (subscribe for download)
๐ RECOMMENDED HARDWARE
โถ Shop: automationdirect.com
โถ Parts Guide: accautomation.ca/purchase-find-parts
๐ฌ Questions? Drop a comment below.
๐ New tutorials every Monday โ Subscribe and hit the bell!
#PLC #StructuredText #IndustrialAutomation #PLCProgramming #ACCAutomation #AI #PLCTutorial #LearnPLC #Shorts
Regards,
Garry
ACC Automation
accautomation.ca
PLC code written by AI pasted straight into the ACC PLC Simulator, connected to the 3D conveyor scene and run. Cycle one, start to auto stop, unedited.
โก QUICK ANSWER
PLC conveyor code generated by an AI completed its first cycle correctly with no edits. Pressing start sent the box forward, the right hand proximity sensor triggered the direction change, the box travelled back, the left hand sensor was reached and the motor stopped on its own. That is the full auto reverse and auto stop sequence working on the first attempt in the ACC PLC Simulator against the 3D conveyor scene. Later cycles and the hand verification that followed are in the written test, including the one edge case that only showed up on inspection.
๐ FULL STEP-BY-STEP + DOWNLOADS (project file, wiring diagrams, screenshots)
accautomation.ca/can-ai-program-a-plc-i-tested-it-live-in-the-acc-plc-simulator
๐ WHAT YOU'LL LEARN
โ Paste Structured Text into the ACC PLC Simulator and connect the 3D conveyor scene
โ Watch a full auto reverse cycle run from start press to motor stop
โ Confirm a direction change is triggered by the end of travel sensor, not a timer
โ Verify auto stop happens at the opposite sensor without an operator command
โ Judge AI generated PLC code on observed behavior rather than on how it reads
โ FREQUENTLY ASKED
Q: Did the AI generated code run without any edits?
A: Yes. It was pasted in as received and the first cycle completed correctly, which is still not the same as being verified.
Q: What triggers the reverse, and what triggers the stop?
A: The right hand proximity sensor reverses direction at the end of forward travel. The left hand sensor ends the cycle and stops the motor.
Q: Is a passing cycle enough to accept the program?
A: No. Correct behavior on a normal run says nothing about scan order or first scan initialization, both of which needed checking by hand.
๐ Full step-by-step, code and wiring diagrams: accautomation.ca/can-ai-program-a-plc-i-tested-it-live-in-the-acc-plc-simulator
๐ MORE RESOURCES
โถ Series: accautomation.ca/series
โถ Free PLC Simulator: accautomation.ca/simulator
โถ PLC Beginners Guide: accautomation.ca/programming/plc-beginners-guide
โถ Free eBooks: accautomation.ca (subscribe for download)
๐ RECOMMENDED HARDWARE
โถ Shop: automationdirect.com
โถ Parts Guide: accautomation.ca/purchase-find-parts
๐ฌ Questions? Drop a comment below.
๐ New tutorials every Monday โ Subscribe and hit the bell!
#PLC #StructuredText #IndustrialAutomation #PLCProgramming #ACCAutomation #AI #PLCTutorial #LearnPLC #Shorts
Regards,
Garry
ACC Automation
accautomation.ca