Uploaded October 2026 | Updated November 2026, 3 hours ago
thehouseofautomata.com
The Huntsman Smoker automaton by Roullet & Decamps, Paris, c.1890.
This film is in almost real time, its warts and all and barely edited. I want to show the reality of restoration in the workshop.
Three processes here:
- Removing a cam that is riveted to its shaft (hitting a thumb).
- Separating the plates and removing the mainspring from its barrel
- Cleaning the component parts of the mechanism
NOTES:
- The rivet was almost flush to begin with and I could not grind it down far enough to see the spread. Therefore I used a punch with too big an end to begin with requiring three attempts.
- Unusually the mainspring was riveted tightly into the barrel and onto the winding arbor making it impossible to remove completely without drilling away the rivets. It happens sometimes on French mechanisms. A clock restorers nightmare.
- My cleaning fluid was embarrassingly filthy looking (but still effective!) and required changing, which I did for a second clean, however the 'new' fluid was still pretty grungy looking. Thats real life.
- The fluid was a Horolene ammoniated water based fluid which is very out of favour these days due to ammonia leaching the zinc out of the brass and 'stress corrosion cracking'. However in this case the mechanism is cleaned not every 10 to 20 years like a clock, but once in every 100 years perhaps, therefore I take a view based on the individual mechanism. Nothing is set in stone.
Comments welcome.
thehouseofautomata.com
The Huntsman Smoker automaton by Roullet & Decamps, Paris, c.1890.
This film is in almost real time, its warts and all and barely edited. I want to show the reality of restoration in the workshop.
Three processes here:
- Removing a cam that is riveted to its shaft (hitting a thumb).
- Separating the plates and removing the mainspring from its barrel
- Cleaning the component parts of the mechanism
NOTES:
- The rivet was almost flush to begin with and I could not grind it down far enough to see the spread. Therefore I used a punch with too big an end to begin with requiring three attempts.
- Unusually the mainspring was riveted tightly into the barrel and onto the winding arbor making it impossible to remove completely without drilling away the rivets. It happens sometimes on French mechanisms. A clock restorers nightmare.
- My cleaning fluid was embarrassingly filthy looking (but still effective!) and required changing, which I did for a second clean, however the 'new' fluid was still pretty grungy looking. Thats real life.
- The fluid was a Horolene ammoniated water based fluid which is very out of favour these days due to ammonia leaching the zinc out of the brass and 'stress corrosion cracking'. However in this case the mechanism is cleaned not every 10 to 20 years like a clock, but once in every 100 years perhaps, therefore I take a view based on the individual mechanism. Nothing is set in stone.
Comments welcome.