W-J-3298 UL Firestop System Installation | Cable Penetrations Through CFS-MSL in Concrete Walls @HiltiNorthAmerica
W-J-3298 UL Firestop System Installation | Cable Penetrations Through CFS-MSL in Concrete Walls  @HiltiNorthAmerica
Uploaded October 2026 | Updated November 2026, 2 days ago
Watch the step-by-step installation of Hilti UL Firestop System W-J-3298, a tested firestop solution for cable penetrations through concrete and concrete block wall assemblies using the Hilti CFS-MSL Modular Sleeve System. This animation demonstrates the key installation steps required to create a re-enterable firestop seal that helps maintain the fire-resistance rating of the wall while supporting future cable additions and modifications.

The Hilti CFS-MSL Modular Sleeve System is designed to streamline cable pathway management, improve installation efficiency, and provide a clean, organized penetration solution for commercial buildings, healthcare facilities, industrial plants, mission-critical infrastructure, and data centers.

System Highlights:

Re-penetrable cable firestop solution

Designed for concrete and concrete block wall assemblies

Supports power, control, communications, and data cables

Facilitates future cable additions and removals

Clean, organized, and inspectable installation

Ideal for high-traffic cable management applications

Helps maintain required fire-resistance ratings

Designed for efficient installation and long-term flexibility

For complete installation requirements and system details, always refer to the UL listing and current Hilti technical documentation found on the Hilti Construction Platform – Firestop Selector: firestop.hilti.com

#Hilti #Firestop #ULSystem #CFSMSL #CablePenetrations #PassiveFireProtection #DataCenterConstruction #HealthcareConstruction #LifeSafety #MEPConstruction #FirestopInstallation #CableManagement #ConstructionEngineering

Time Stamps

0:00 - 0:07 Intro

0:07 - 0:13 CP 648E Wrap Strip Install around Ganged CFS-MSL Modular Sleeves

0:13 - 0:42 CFS-MSL GPA Adjustable Flange Assembly

0:42 - 0:51 Penetrant Installation through CFS-MSL Modular Sleeves

0:51 - 1:07 Installed System & Outro
Frequently Asked Questions (FAQ)

What is a UL firestop system? 
A UL firestop system is a tested and listed assembly designed to help maintain the fire-resistance rating of a wall or floor after it has been penetrated by pipes, cables, conduits, ducts, or other building services. 

Why is firestopping required? 
Firestopping helps limit the spread of fire, smoke, and hot gases through fire-resistance-rated assemblies, supporting compartmentation and life-safety objectives.
 
What do the UL penetration system numbers mean? 
UL penetration system numbers (such as W-L-3507, W-J-3298, or C-AJ-2835) identify a specific tested assembly that includes the construction type, penetrant, opening size, firestop materials, and installation requirements. 

What do the UL joint system numbers mean? 
UL joint system numbers (such as HW-D-0209, FW-D-1037, or BW-S-0002) identify a specific tested assembly that includes the construction assembly, type of joint, movement capability, joint width, firestop materials, and installation requirements.  

Can I substitute products or change installation details? 
No. Firestop systems should be installed exactly as tested and listed. Changes to products, dimensions, penetrant types, or assembly details may affect compliance and performance. 

Where can I find the complete UL system details? 
Always refer to the official UL listing and current Hilti technical documentation for complete installation requirements, limitations, and approved configurations. 

What if my field condition does not match a tested system? 
If no listed system matches the field condition, a Technical Evaluation also known as an Engineering Judgement (EJ) may be required. Hilti provides engineering support and EJ services through the Hilti Construction Platform: hcp.hilti.com
 
Who should use these installation videos? 
These videos are intended for contractors, firestop specialty contractors, inspectors, designers, engineers, and anyone involved in firestop system installation or review. 
Are these videos a replacement for the UL listing? No. These videos are visual installation aids only. The official UL system listing and applicable project documents govern the installation requirements. 

How do I find the right firestop system for my application? 
The Hilti Construction Platform Firestop Selector can help identify tested and listed firestop systems based on the penetrant type, assembly construction, fire rating, and other project conditions.

Where can I learn more about Hilti firestop systems?
Explore:
Hilti Construction Platform
hcp.hilti.com
Firestop Selector
firestop.hilti.com
Firestop Resource Center
hilti.com/content/landing-page/local/firestop-resource-center
Hilti Academy training resources for additional firestop documentation, training, and technical support
academy.hilti.com/learn/signin

#hilti #construction

➡️ Follow Hilti North America
instagram.com/hiltinorthamerica
facebook.com/hiltinorthamerica
linkedin.com/company/hilti-usa
W-J-3298 UL Firestop System Installation | Cable Penetrations Through CFS-MSL in Concrete WallsCall them out in the comments! 💭Great question!Traditional welding slowing your project down? 🤔The LadyPlumberF-A-2025 UL Firestop System Installation (US Only) | Plastic Pipe Through Concrete Over Metal DeckOne cordless coring setup worth knowing about. 👀
Hilti North America |

W-J-3298 UL Firestop System Installation | Cable Penetrations Through CFS-MSL in Concrete Walls

SHARE TO X SHARE TO REDDIT SHARE TO FACEBOOK WALLPAPER