Uploaded October 2026 | Updated November 2026, 2 days ago
*DISCLAIMER: The firestop system shown in this video is based on a UL-listed design tested for the U.S. market. Use outside the United States may require different approvals, testing, or system designs to meet local building code requirements.*

Learn how to install Hilti Firestop System F-A-2025, a UL-tested firestop system for plastic pipe penetrations through concrete over metal deck floor assemblies. This installation video demonstrates the proper installation of the Hilti CP 643N Firestop Collar, mineral wool, and Hilti FS-ONE MAX Intumescent Firestop Sealant to help maintain the fire-resistance rating of the floor assembly.

Designed for use with PVC, ABS, FRPP, and CPVC plastic piping systems, F-A-2025 provides a 2-hour F-Rating and 2-hour T-Rating for concrete over metal deck floor assemblies. The system utilizes a firestop collar mounted beneath the deck along with firestop sealant and mineral wool to protect the opening in the event of a fire.

System Highlights:

Accommodates PVC, ABS, FRPP, and CPVC pipes up to 6 in. diameter

F-Rating: Up to 2-hour

T-Rating: Up to 2-hour

Supports challenging penetrations through corrugated metal deck profiles

Features CP 643N Firestop Collar and FS-ONE MAX

For complete installation requirements and system details, always refer to the UL listing and current Hilti technical documentation found on the Hilti Construction Platform – Firestop Selector: Firestop

#Hilti #Firestop #PassiveFireProtection #ULSystems #LifeSafety #FSONEMAX #CP643N #ConstructionSafety #BuildingSafety #FirestopInstallation

Time Stamps

0:00 – Intro

0:11 – Penetrant install into concrete over metal deck

0:14 – Sheet metal plate attachment into valley of decking

0:23 – Mineral wool and FS-ONE MAX sealant install in metal deck flutes

0:31 – Hilti CP 643N firestop collar installation

0:47 – FS-ONE MAX sealant application around sheet metal plate edge

0:50 – System overview and outro

Frequently Asked Questions (FAQ)

What is a UL firestop system? 
A UL firestop system is a tested and listed assembly designed to help maintain the fire-resistance rating of a wall or floor after it has been penetrated by pipes, cables, conduits, ducts, or other building services. 
Why is firestopping required? 
Firestopping helps limit the spread of fire, smoke, and hot gases through fire-resistance-rated assemblies, supporting compartmentation and life-safety objectives.
What do the UL penetration system numbers mean? 
UL penetration system numbers (such as W-L-3507, W-J-3298, or C-AJ-2835) identify a specific tested assembly that includes the construction type, penetrant, opening size, firestop materials, and installation requirements. 
What do the UL joint system numbers mean? 
UL joint system numbers (such as HW-D-0209, FW-D-1037, or BW-S-0002) identify a specific tested assembly that includes the construction assembly, type of joint, movement capability, joint width, firestop materials, and installation requirements.  
Can I substitute products or change installation details? 
No. Firestop systems should be installed exactly as tested and listed. Changes to products, dimensions, penetrant types, or assembly details may affect compliance and performance. 
Where can I find the complete UL system details? 
Always refer to the official UL listing and current Hilti technical documentation for complete installation requirements, limitations, and approved configurations. 
What if my field condition does not match a tested system? 
If no listed system matches the field condition, a Technical Evaluation also known as an Engineering Judgement (EJ) may be required. Hilti provides engineering support and EJ services through the Hilti Construction Platform: hcp.hilti.com
Who should use these installation videos? 
These videos are intended for contractors, firestop specialty contractors, inspectors, designers, engineers, and anyone involved in firestop system installation or review. 
Are these videos a replacement for the UL listing? No. These videos are visual installation aids only. The official UL system listing and applicable project documents govern the installation requirements. 
How do I find the right firestop system for my application? 
The Hilti Construction Platform Firestop Selector can help identify tested and listed firestop systems based on the penetrant type, assembly construction, fire rating, and other project conditions.
Where can I learn more about Hilti firestop systems?
Explore:
Hilti Construction Platform
hcp.hilti.com
Firestop Selector
firestop.hilti.com
Firestop Resource Center
hilti.com/content/landing-page/local/firestop-resource-center
Hilti Academy training resources for additional firestop documentation, training, and technical support
academy.hilti.com/learn/signin
#hilti
Follow:
instagram.com/hiltinorthamerica
facebook.com/hiltinorthamerica
linkedin.com/company/hilti-usa
F-A-2025 UL Firestop System Installation (US Only) | Plastic Pipe Through Concrete Over Metal DeckOne cordless coring setup worth knowing about. 👀
Hilti North America |

F-A-2025 UL Firestop System Installation (US Only) | Plastic Pipe Through Concrete Over Metal Deck

SHARE TO X SHARE TO REDDIT SHARE TO FACEBOOK WALLPAPER