Unfortunately the SMC T52 Emperor ceiling fan project will end in a fail. I didn't check the depth of the socket in relation to the shaft before pounding on the bearing and the socket got stuck on the shaft. An absurd amount of force was required to remove the stuck socket, which then resulted in damage to both the windings and the laminations. It's still not beyond repair, the laminations can be put back together and the windings can be rewound, but this is a skillset I don't yet possess at this time.
The unit will be put into storage and perhaps revisited some day. I am so thoroughly disappointed in this. I spent a lot of tedious hours fixing the windings from the previous owner's mistake. I spent money on bearings. I had a lot invested in this, and now it's all gone to waste.
This is a good lesson in repairs -- when something happens that's frustrating, STOP. Leave the project and revisit at a later time with a clear head. Since the socket was so locked onto the shaft, the unit still might have gotten damaged regardless trying to remove it, but if I wasn't mad about it, I would have used the force a lot more carefully and potentially prevented damage.
Unfortunately the SMC T52 Emperor ceiling fan project will end in a fail. I didn't check the depth of the socket in relation to the shaft before pounding on the bearing and the socket got stuck on the shaft. An absurd amount of force was required to remove the stuck socket, which then resulted in damage to both the windings and the laminations. It's still not beyond repair, the laminations can be put back together and the windings can be rewound, but this is a skillset I don't yet possess at this time.
The unit will be put into storage and perhaps revisited some day. I am so thoroughly disappointed in this. I spent a lot of tedious hours fixing the windings from the previous owner's mistake. I spent money on bearings. I had a lot invested in this, and now it's all gone to waste.
This is a good lesson in repairs -- when something happens that's frustrating, STOP. Leave the project and revisit at a later time with a clear head. Since the socket was so locked onto the shaft, the unit still might have gotten damaged regardless trying to remove it, but if I wasn't mad about it, I would have used the force a lot more carefully and potentially prevented damage.










![52 Hunter 22272 The Original Ceiling Fan in Brown/Brass with Cane Blades | Computer Room Install
A 52 Hunter 22272 The Original ceiling fan in brown/polished brass with cane blades installed in the computer. This is a 2-speed non-reversible model with shaded pole motor. I believe the unit dates back to the late 1970s or 1980s.
This is an insanely powerful fan. The PSC-powered versions of The Original are objectively the best residential grade ceiling fans ever made. This fan pushes significantly more air than all other residential grade fans Ive tested and is nearly silent during operation. These are a rare case where you get looks, performance, reliability, and longevity all in one package.
Unfortunately this one does have some issues; it came to me with a mis-matched set of irons which causes significant wobble and the mounting system is incomplete. I am seeking replacements for these 2 components.
The specifications I measured during the video are as followed, in the format of [Current (amps) / Power (watts) / Power Factor / Speed (RPM) / Air flow volume (CFM) / Efficiency (CFM/watt)].
High: 2.48 / 155 / 0.52 / 196 / 9,912 / 64.
Low: 1.2 / 76.5 / 0.51 / 105 / 5,782 / 76. 52 Hunter 22272 The Original Ceiling Fan in Brown/Brass with Cane Blades | Computer Room Install](https://i.ytimg.com/vi/yYQbBJOSE-I/mqdefault.jpg)