We take a look at the Harmony Analog Converters from Schneider Electric. They provide isolation, conversion, and conditioning between field level sensors and automation platforms.
Inside the box, you’ll find the Harmony Analog Converter. This model is designed to accept and replicate a 4 to 20 milliamp signal and has an ultra-slim 6.2 millimeter width.
In this demo we’re going to drive a 4 to 20 milliamp current into the input and measure the output.
The input signal will be driven by a power supply operating in constant current mode and connected to terminals 6 and 7. A 24 volt power supply is connected to terminals 3 and 4 to power the module, and the replicated current loop is output on terminals 1 and 2.
With everything connected, if we adjust the input current loop we see the output current loop mirror it. 4 to 20 milliamp current loops can already be used over long distances, so the purpose here usually isn’t to repeat for extended range. Rather, this provides galvanic isolation between the signal source driving the input and a PLC connected to the output. It also allows us to tap into an existing system using the current loop, providing the mirrored loop that can be passed to another data acquisition device without disturbing the existing system.
digikey.com/en/products/featured/harmony-analog-converters/1582341387875904
digikey.com/en/products/detail/schneider-electric/RMC1AABD/29528714
Maker.io - digikey.com/en/maker
DigiKey’s Blog – TheCircuit digikey.com/en/blog
Connect with DigiKey on Facebook facebook.com/digikey.electronics
And follow us on X https://x.com/digikey
We take a look at the Harmony Analog Converters from Schneider Electric. They provide isolation, conversion, and conditioning between field level sensors and automation platforms.
Inside the box, you’ll find the Harmony Analog Converter. This model is designed to accept and replicate a 4 to 20 milliamp signal and has an ultra-slim 6.2 millimeter width.
In this demo we’re going to drive a 4 to 20 milliamp current into the input and measure the output.
The input signal will be driven by a power supply operating in constant current mode and connected to terminals 6 and 7. A 24 volt power supply is connected to terminals 3 and 4 to power the module, and the replicated current loop is output on terminals 1 and 2.
With everything connected, if we adjust the input current loop we see the output current loop mirror it. 4 to 20 milliamp current loops can already be used over long distances, so the purpose here usually isn’t to repeat for extended range. Rather, this provides galvanic isolation between the signal source driving the input and a PLC connected to the output. It also allows us to tap into an existing system using the current loop, providing the mirrored loop that can be passed to another data acquisition device without disturbing the existing system.