Reverse-engineering and testing an x-ray filament supply @AppliedScience
Reverse-engineering and testing an x-ray filament supply  @AppliedScience
Uploaded October 2012 | Updated September 2026, 2 weeks ago
I bought a set of x-ray equipment on eBay, which included an x-ray head unit, 50KV supply, and filament power supply. The filament supply has a 25-pin connector, and no data or markings on the case or board. I spent some time reverse-engineering the circuit, and determined how it should be connected to make an emission-controlled x-ray system. I tested the whole thing, and it appears to be working as intended at 50KV / 1 mA. The head unit produces a beam of about 25 degrees total angle.
Reverse-engineering and testing an x-ray filament supplyFlashing Light Prize 2018 - Sunscreen, UV, and neonCryogenic treatment of drill bits: tested 2X lifetime and microstructure analysisDIY X-ray CT scanner controlled by an ArduinoReview of National Instruments VirtualBenchHypercentric optics: A camera lens that can see behind objectsAtomic Layer Deposition of copper - If you like sputtering, youll love this!Behind the scenes at Applied Science: Why video? Camera gear. Shop tour.Milling machine tutorial - cutter selection, speeds and feeds, coolant, high speed machiningEtching silicon wafers to make colorful Rugate optical filters (porous silicon)X-ray timelapse of fluid movement in plants, stop-motion animation, sensor teardown/repairThe physics of floating screwdrivers
Applied Science |

Reverse-engineering and testing an x-ray filament supply

SHARE TO X SHARE TO REDDIT SHARE TO FACEBOOK WALLPAPER