One-shot logic with an edge contact: fire an action for exactly one PLC scan on the rising edge of a signal โ precise, single-pulse triggering in ladder logic. Here's how.
โก QUICK ANSWER
A one-shot (edge contact) passes power for exactly one PLC scan on the rising edge of a signal โ the instant the input goes from off to on. Instead of an output staying true the whole time an input is held, the one-shot gives you a single, precise pulse. That's essential when you want an action to happen once per event, not repeatedly every scan the input is on โ for example incrementing a counter once per button press, latching a value, or triggering a sequence step exactly once. A rising-edge (normally-open edge) contact fires on the off-to-on transition; a falling-edge contact fires on the on-to-off transition. Using the edge contact keeps your logic precise and prevents actions from repeating unintentionally while a signal is held. Here it's shown on the P1-M622-16DR. The full contact-and-coil walkthrough is in the guide below.
๐ FULL WRITTEN TUTORIAL + DOWNLOADS (contact & coil instructions)
accautomation.ca/p1-m622-16dr-mini-plc-contact-and-coil-instructions
๐ WHAT YOU'LL LEARN
โ What a one-shot (edge contact) does โ one pulse for a single PLC scan
โ How a rising-edge contact fires on the off-to-on transition
โ Why you use a one-shot to trigger an action once per event, not every scan
โ Common uses โ counting once per press, latching, stepping a sequence
โ FREQUENTLY ASKED
Q: What is a one-shot in PLC ladder logic?
A: It's an edge contact that passes power for a single PLC scan on the rising edge of a signal, giving one precise pulse instead of staying true while the input is held. The full walkthrough is in the guide.
Q: Why use a one-shot instead of a normal contact?
A: A normal contact stays true the whole time the input is on, so an action repeats every scan. A one-shot fires exactly once per event โ ideal for counting a press, latching, or stepping a sequence.
๐ Full contact & coil guide: accautomation.ca/p1-m622-16dr-mini-plc-contact-and-coil-instructions
๐ MORE RESOURCES
โถ Series: accautomation.ca/series/productivity-plc
โถ PLC Beginners Guide: accautomation.ca/programming/plc-beginners-guide
โถ Free eBooks: accautomation.ca (subscribe for download)
๐ RECOMMENDED HARDWARE
โถ Shop: automationdirect.com
โถ Parts Guide: accautomation.ca/purchase-find-parts
๐ฌ Questions? Drop a comment below.
๐ New tutorials every Monday โ Subscribe and hit the bell!
#PLC #LadderLogic #IndustrialAutomation #PLCProgramming #ACCAutomation #ProductivityPLC #AutomationDirect #OneShot #EdgeContact #Shorts
Regards,
Garry
ACC Automation
accautomation.ca
One-shot logic with an edge contact: fire an action for exactly one PLC scan on the rising edge of a signal โ precise, single-pulse triggering in ladder logic. Here's how.
โก QUICK ANSWER
A one-shot (edge contact) passes power for exactly one PLC scan on the rising edge of a signal โ the instant the input goes from off to on. Instead of an output staying true the whole time an input is held, the one-shot gives you a single, precise pulse. That's essential when you want an action to happen once per event, not repeatedly every scan the input is on โ for example incrementing a counter once per button press, latching a value, or triggering a sequence step exactly once. A rising-edge (normally-open edge) contact fires on the off-to-on transition; a falling-edge contact fires on the on-to-off transition. Using the edge contact keeps your logic precise and prevents actions from repeating unintentionally while a signal is held. Here it's shown on the P1-M622-16DR. The full contact-and-coil walkthrough is in the guide below.
๐ FULL WRITTEN TUTORIAL + DOWNLOADS (contact & coil instructions)
accautomation.ca/p1-m622-16dr-mini-plc-contact-and-coil-instructions
๐ WHAT YOU'LL LEARN
โ What a one-shot (edge contact) does โ one pulse for a single PLC scan
โ How a rising-edge contact fires on the off-to-on transition
โ Why you use a one-shot to trigger an action once per event, not every scan
โ Common uses โ counting once per press, latching, stepping a sequence
โ FREQUENTLY ASKED
Q: What is a one-shot in PLC ladder logic?
A: It's an edge contact that passes power for a single PLC scan on the rising edge of a signal, giving one precise pulse instead of staying true while the input is held. The full walkthrough is in the guide.
Q: Why use a one-shot instead of a normal contact?
A: A normal contact stays true the whole time the input is on, so an action repeats every scan. A one-shot fires exactly once per event โ ideal for counting a press, latching, or stepping a sequence.
๐ Full contact & coil guide: accautomation.ca/p1-m622-16dr-mini-plc-contact-and-coil-instructions
๐ MORE RESOURCES
โถ Series: accautomation.ca/series/productivity-plc
โถ PLC Beginners Guide: accautomation.ca/programming/plc-beginners-guide
โถ Free eBooks: accautomation.ca (subscribe for download)
๐ RECOMMENDED HARDWARE
โถ Shop: automationdirect.com
โถ Parts Guide: accautomation.ca/purchase-find-parts
๐ฌ Questions? Drop a comment below.
๐ New tutorials every Monday โ Subscribe and hit the bell!
#PLC #LadderLogic #IndustrialAutomation #PLCProgramming #ACCAutomation #ProductivityPLC #AutomationDirect #OneShot #EdgeContact #Shorts
Regards,
Garry
ACC Automation
accautomation.ca