Uploaded September 2026 | Updated November 2026, 3 hours ago
Ty Branaman joins us to break down how to get more out of measureQuick by feeding it better data. The core idea is simple: the more accurate information you enter into the app, the better and more precise the answers you get back, especially once you have your workflow dialed in and know where to look for shortcuts.
We dig into commonly skipped inputs that quietly wreck your diagnostics, including outdoor ambient temperature taken in the shade (not sun-soaked or from a weather app), discharge line temperature, voltage and amperage, and total external static pressure. Ty explains why entering the refrigerant metering device type and even model/serial info sharpens the app's calculations, and how a system can look "all green" on paper while still hiding a real airflow or capacity issue underneath.
You'll also hear a great analogy comparing the red/green/yellow flagging system to getting your blood work done at the doctor. You don't need to understand every number to know something's off, and that same simplicity is exactly what makes it easier to build trust with customers who don't know a superheat from a subcooling reading.
Other topics covered:
Why ECM and PSC blower motors read differently on amp draw, and how power factor plays into calculating true wattage
How outdoor and indoor temperature swings affect a system's real-world capacity versus its rated tonnage
The "wet condenser trick" some techs use to fake better readings, and why you should always take your data before hosing anything down
Checking attic relative humidity as a lead for building science issues like condensation and duct leakage
Which handful of readings actually matter most on every call: static pressure, wet bulb, two clamps, and two pressure probes
Whether you're brand new to the platform or have been using it for years, this conversation is packed with practical ways to make your diagnostics faster, more accurate, and easier to explain to the customer standing next to you.
Using Power Factor to Check Capacitors Under Load: hvacrschool.com/use-power-factor-to-check-capacitors-under-load
---
NEXT VIDEO
Using measureQuick to Commission a New HVAC System
youtube.com/watch?v=3EOIUDvQ4j8
KEEP LEARNING
Start here:
hvacrschool.com/start
Free HVAC/R training, tech tips, quizzes, calculators, courses, and more:
hvacrschool.com
Listen to the HVAC School podcast:
hvacrschool.com/podcast
Get the HVAC School app:
hvacrschool.com/apps-page
HVAC School provides free HVAC/R training—primarily for techs, by techs. The goal is not just to collect facts. It is to understand the system well enough to apply what you know in the field.
Questions or corrections? Leave a comment and include the equipment model, measurements, and source when you can. None of us gets everything right, and good measurements beat confident guesses.
This content is educational. Follow manufacturer instructions, use proper PPE and safe work practices, and comply with the codes and standards that apply to your equipment and jurisdiction.
Ty Branaman joins us to break down how to get more out of measureQuick by feeding it better data. The core idea is simple: the more accurate information you enter into the app, the better and more precise the answers you get back, especially once you have your workflow dialed in and know where to look for shortcuts.
We dig into commonly skipped inputs that quietly wreck your diagnostics, including outdoor ambient temperature taken in the shade (not sun-soaked or from a weather app), discharge line temperature, voltage and amperage, and total external static pressure. Ty explains why entering the refrigerant metering device type and even model/serial info sharpens the app's calculations, and how a system can look "all green" on paper while still hiding a real airflow or capacity issue underneath.
You'll also hear a great analogy comparing the red/green/yellow flagging system to getting your blood work done at the doctor. You don't need to understand every number to know something's off, and that same simplicity is exactly what makes it easier to build trust with customers who don't know a superheat from a subcooling reading.
Other topics covered:
Why ECM and PSC blower motors read differently on amp draw, and how power factor plays into calculating true wattage
How outdoor and indoor temperature swings affect a system's real-world capacity versus its rated tonnage
The "wet condenser trick" some techs use to fake better readings, and why you should always take your data before hosing anything down
Checking attic relative humidity as a lead for building science issues like condensation and duct leakage
Which handful of readings actually matter most on every call: static pressure, wet bulb, two clamps, and two pressure probes
Whether you're brand new to the platform or have been using it for years, this conversation is packed with practical ways to make your diagnostics faster, more accurate, and easier to explain to the customer standing next to you.
Using Power Factor to Check Capacitors Under Load: hvacrschool.com/use-power-factor-to-check-capacitors-under-load
---
NEXT VIDEO
Using measureQuick to Commission a New HVAC System
youtube.com/watch?v=3EOIUDvQ4j8
KEEP LEARNING
Start here:
hvacrschool.com/start
Free HVAC/R training, tech tips, quizzes, calculators, courses, and more:
hvacrschool.com
Listen to the HVAC School podcast:
hvacrschool.com/podcast
Get the HVAC School app:
hvacrschool.com/apps-page
HVAC School provides free HVAC/R training—primarily for techs, by techs. The goal is not just to collect facts. It is to understand the system well enough to apply what you know in the field.
Questions or corrections? Leave a comment and include the equipment model, measurements, and source when you can. None of us gets everything right, and good measurements beat confident guesses.
This content is educational. Follow manufacturer instructions, use proper PPE and safe work practices, and comply with the codes and standards that apply to your equipment and jurisdiction.