0:00 - Generator Hookup Materials Intro
0:30 - Generator Interlock Kit & 2-Pole Breaker
1:05 - Why Backfeeding Is Illegal
1:52 - 10-3 W/Ground Cable
2:37 - Power Inlet Box
3:44 - Generator Cord
4:13 - Diagram Overview
5:31 - SUBSCRIBE!!!
Here we go over the different supplies that you will need in order to hookup your generator to your main electrical panel by way of a power inlet box, generator cord, 30 ampere breaker, and a generator interlock kit.
This is the most economical and low hassle method of connecting a generator to your house in a power outage in my opinion.
MAKE SURE that you purchase the correct interlock kit! I ordered the wrong on the first time around so do your homework before ordering.
Also, if you have a generator with a 50 amp 240v socket then you should consider upgrading all of these components to match that 50A capacity.
Note that if you are going to be running the wire to your inlet box outdoors or in a damp/wet location you need to buy the UF rated wire. Conduit alone is not sufficient in order to use standard "Romex" outdoors and it does not meet code.
Thanks for watching and subscribing! As an Amazon affiliate I earn from qualifying purchases. Thank you for your support!
Was this video helpful to you? Send a tip:paypal.me/bensahlstrom
Become a Patron: patreon.com/bensahlstrom
Blessings from Minnesota,
Ben
Power Inlet Box: amzn.to/2B59ZNq
My Favorite Tool: amzn.to/3NIFJuO
30A Generator Cords: amzn.to/35q9ZWj
Red 22-6AWG Wire Nut Connectors: amzn.to/33s8ll1
30A Circuit Breakers: amzn.to/2MvYmV6
10/3 Standard Orange Indoor Romex: amzn.to/2nHEJkE
10/3 WG UF for Outdoor/Wet Location: amzn.to/2B7u6ug
Square D QO Generator Interlock Kits
Indoor 150A - 225A: amzn.to/35qp7mp
Outdoor 150A - 225A: amzn.to/328thNX
Square D Homeline Generator Interlock Kits
Indoor 150A - 225A: amzn.to/2OGAxfY
Outdoor 150A - 225A: amzn.to/2B1LeSb
Square D 100A Interlock Kits: amzn.to/2VxohzZ
Eaton Interlock Kits: amzn.to/33p0Aww
Siemens Interlock Kits: amzn.to/2B0wu6i
0:00 - Generator Hookup Materials Intro
0:30 - Generator Interlock Kit & 2-Pole Breaker
1:05 - Why Backfeeding Is Illegal
1:52 - 10-3 W/Ground Cable
2:37 - Power Inlet Box
3:44 - Generator Cord
4:13 - Diagram Overview
5:31 - SUBSCRIBE!!!
Here we go over the different supplies that you will need in order to hookup your generator to your main electrical panel by way of a power inlet box, generator cord, 30 ampere breaker, and a generator interlock kit.
This is the most economical and low hassle method of connecting a generator to your house in a power outage in my opinion.
MAKE SURE that you purchase the correct interlock kit! I ordered the wrong on the first time around so do your homework before ordering.
Also, if you have a generator with a 50 amp 240v socket then you should consider upgrading all of these components to match that 50A capacity.
Note that if you are going to be running the wire to your inlet box outdoors or in a damp/wet location you need to buy the UF rated wire. Conduit alone is not sufficient in order to use standard "Romex" outdoors and it does not meet code.
Thanks for watching and subscribing! As an Amazon affiliate I earn from qualifying purchases. Thank you for your support!