Uploaded September 2023 | Updated November 2026, 4 minutes ago
There’s only room for one pish-head at Elex, so Linda gamely gives up the demon drink to allow me to stagger up to the plate. Our thanks to all those we bumped into for giving us their time. Despite Elex being smaller than CEF Live and our being there for two days, we still didn’t get to see everything and there were a few names notable by their absence.
There are no shoutouts on this one as it contains no technical content. I also have no control of any adverts YT stick on it as that all goes to the music copyright holders.
That Hager rig was interesting. The external box was probably just the buttons; I suspect there was a PCB in the CU which injected arc signatures into the AFDD. If that's possible to do, I wonder how long before it gets built into MFTs?
Links:
The music is of course Pump Up The Volume by M.A.A.R.S
amzn.to/3LqErGs
Sam’s Electrician’s Pod shop – don’t forget that BundySucksCock10 discount folks:
https://www.electricianspod.shop/
The charity Electrical Safety First:
electricalsafetyfirst.org.uk
… a direct link to their Best Practice Guides:
electricalsafetyfirst.org.uk/professional-resources/best-practice-guides
… and the Wiring Regulations Advisory Group (WRAG):
electricalsafetyfirst.org.uk/professional-resources/technical-e-news/the-wrag
Affiliate links:
For a shout out in a future video, you can buy us a Heineken Zero here or with the SuperThanks button:
buymeacoffee.com/dseselectric
My nonsense Amazon storefront:
amazon.co.uk/shop/davidsaveryelectricalservices
£50 off YourTradeBase:
go.yourtradebase.com/refer/3M6F3301
SumUp credit/debit card processing:
http://r.sumup.com/referrals/oBF5S
Get £40 credit for switching to Zen Internet:
zen.mention-me.com/m/ol/rt4lh-david-savery
For web hosting, get £10 off at Krystal with the code DSESELECTRIC at checkout!
krystal.uk
Recycle your scrap cable at greencable.com - use referral code GREENCABLET1ZT when setting up an account and I'll get a tenner while you get a recycling bin delivered at no cost!
For more on my video content, refer to my OnlyFans page (not really an OnlyFans page):
dses.co.uk/index.php/news/244-onlyfans or at dses.tv
There’s only room for one pish-head at Elex, so Linda gamely gives up the demon drink to allow me to stagger up to the plate. Our thanks to all those we bumped into for giving us their time. Despite Elex being smaller than CEF Live and our being there for two days, we still didn’t get to see everything and there were a few names notable by their absence.
There are no shoutouts on this one as it contains no technical content. I also have no control of any adverts YT stick on it as that all goes to the music copyright holders.
That Hager rig was interesting. The external box was probably just the buttons; I suspect there was a PCB in the CU which injected arc signatures into the AFDD. If that's possible to do, I wonder how long before it gets built into MFTs?
Links:
The music is of course Pump Up The Volume by M.A.A.R.S
amzn.to/3LqErGs
Sam’s Electrician’s Pod shop – don’t forget that BundySucksCock10 discount folks:
https://www.electricianspod.shop/
The charity Electrical Safety First:
electricalsafetyfirst.org.uk
… a direct link to their Best Practice Guides:
electricalsafetyfirst.org.uk/professional-resources/best-practice-guides
… and the Wiring Regulations Advisory Group (WRAG):
electricalsafetyfirst.org.uk/professional-resources/technical-e-news/the-wrag
Affiliate links:
For a shout out in a future video, you can buy us a Heineken Zero here or with the SuperThanks button:
buymeacoffee.com/dseselectric
My nonsense Amazon storefront:
amazon.co.uk/shop/davidsaveryelectricalservices
£50 off YourTradeBase:
go.yourtradebase.com/refer/3M6F3301
SumUp credit/debit card processing:
http://r.sumup.com/referrals/oBF5S
Get £40 credit for switching to Zen Internet:
zen.mention-me.com/m/ol/rt4lh-david-savery
For web hosting, get £10 off at Krystal with the code DSESELECTRIC at checkout!
krystal.uk
Recycle your scrap cable at greencable.com - use referral code GREENCABLET1ZT when setting up an account and I'll get a tenner while you get a recycling bin delivered at no cost!
For more on my video content, refer to my OnlyFans page (not really an OnlyFans page):
dses.co.uk/index.php/news/244-onlyfans or at dses.tv






![EICR failure site - righting the wrongs
This is a follow-up video to an EICR we performed back in March 2019 where the electrical installation had exceeded the capacity of the RCD on site resulting in its mechanical failure.
Original video: https://youtu.be/cJuO7oKSDMs
The demand problem has been reduced in the following ways:
One of the three electric showers has already been decommissioned.
A second electric shower is to be decommissioned and a new one is to be installed from one of the two gas boilers.
Three of the socket circuits have been reduced to 20A.
New maximum demand calculations/measurements:
Circuit 1: Shower: 7500W 32A
Circuit 2: Shower: 7500W 32A
Circuit 3: Cooker: 4600W: 10A + 30% of remainder = 13A [diversity calculation]
Circuit 4: Cooker: 4800W: 10A + 30% of remainder = 13.27A [diversity calculation]
Circuit 5: Socket ring: 32A [no diversity]
Circuit 6: Socket ring: 12.8A [40% diversity]
Circuit 7: Socket radial: 8A [40% diversity]
Circuit 8: Socket radial: 8A [40% diversity]
Circuit 9: Socket radial: 8A [40% diversity]
Circuit 10: Socket radial: 8A [40% diversity]
Circuit 11: Shed [DB2]: 16A
Circuit 12: Water heater: 13A
Circuit 13: Lighting: 1.6A [Actual]
Circuit 14: Lighting: 0.3A [Actual]
Circuit 15: Lighting: 0.25A [Actual]
Circuit 16: Lighting: 0.5A [Actual]
Circuit 17: Lighting: 0.6A [Actual]
Circuit 18: Doorbell/lighting: 0.05A [Actual]
Circuit 19: Lighting: 0.7A [Actual]
Adding this lot up gives a new maximum demand on paper of about 200A which is twice what the main fuse is rated for. But then, this is why the maximum demand calculation is a bit of a nonsense. Those socket circuits aren’t really going to be pulling 76.8A at any given time on any given day, the shed isn’t likely to be pulling 16A, the water heater is only used when the combi boiler breaks down, etc. The problem before was three electric showers plus all the socket outlets hanging off a single 63A RCD, but now that everything has been split out there is no single point at the CU which is being exposed to more current than it is rated for.
A few additional notes not covered on camera to fend off some of the questions likely to be asked in the comments….
I would have preferred to terminate the SWA directly onto the metal CU enclosure, but the knockout on the right side of the board is 32mm. Had there been a 20mm knockout, I would have done this, but I didn’t want to holesaw one in, so I went for the quicker and easier option of terminating it onto a Wiska box with a bit of T&E then going to the board. A Wiska locking nut makes for an easy way to terminate the sheath.
As shown, CP Fusebox have said on Twitter that their Type-A small form factor RCBO’s should be out around October 2019 and should have longer neutral flyleads.
Many circuits required extending, some of which were in junction enclosures, others were extended in the box trunking using Wago connectors. This work took place a while ago, it’s just taken me some time to get organised enough to edit it together and some footage was lost, so apologies that there are one or two things not shown here.
Some people are very neat with their cable forming in consumer units, but this job took all day, and this is neat enough as far as I’m concerned. I also see some people cable tie the wires to keep them together which is a no-no as it brings grouping factors into play. For more on that, I refer you to this excellent video from SparkyNinja:
https://www.youtube.com/watch?v=e3xA3t6wAmY
A couple of pedants commented on the previous video that “FAIL” was the wrong term for an EICR and I shouldn’t have described it that way. Well, the installation FAILED to meet the criteria required by the reporting process for a ‘satisfactory’ outcome. So bore off.
Links:
CP Fusebox gear was sourced from Gil-Lec Electrical:
https://www.gil-lec.co.uk/circuit-protection/consumer-units-accessories/fusebox-consumer-units
Haste UK: http://www.hasteltd.co.uk/
YouTube channels showing CU installations and discussing Type-A RCD/RCBO’s:
CJR Electrical:
https://www.youtube.com/channel/UCoVvd6bZ6LSKv-ePiow1evg
DSS Electrical:
https://www.youtube.com/channel/UCC9nYFJuVVOuH49xR_t9vJg
Artisan Electrics:
https://www.youtube.com/channel/UCUYJhbsrC1bvVWzgUq83K4A
e5 Group:
https://www.youtube.com/channel/UCAKzna71V7xKMTlNTS3eKhA
…and may I also ask you to check out J Beck Electrical ‘cos I like the way his dick swings:
https://www.youtube.com/channel/UCkezXm0I_KhjLH_DnLXFN5A/videos
Affiliate links:
Wiska earth locking nuts: https://amzn.to/2YP1HqJ
Wagobox enclosures: https://amzn.to/2YGbnU1
Wago connectors: https://amzn.to/2YBNxEZ
Brother label printer: https://amzn.to/318Lbzc EICR failure site - righting the wrongs](https://i.ytimg.com/vi/zRrK2YOPJZc/mqdefault.jpg)