Uploaded April 2026 | Updated November 2026, 6 days ago
Especially if you load the same volume as your samples, doing this will help promote a consistent running front (avoiding artifacts like smiling, where the middle lanes run faster than the outer lanes, giving your bands an evil grin . . .)
You want to be strategic about where you put them – I like to put them in the edge lanes, between sets of samples, &/or next to highly-concentrated and/or viscous samples, which have a tendency to warp the neighboring lanes.
I recommend loading these “blanks” last – just in case . . . This way, you have backup wells in case you end up needing them (because of a loading error in one of the other lanes, etc.)
Note: 1X indicates that it’s at the working concentration. So for example, you might have a 4X sample loading buffer that you normally mix one volume of that with 3 volumes of sample (e.g., if you wanted to prepare 20 µL worth, you’d mix 20/4 = 5 µL loading buffer + 15 µL protein solution). For the blanks, in this case, you’d mix the loading buffer with water (or a buffer) instead of protein solution.
More tips on loading PAGE gels: youtu.be/8MCfiSiJDNU
More random practical lab tips & tricks: bit.ly/lab_tricks_page
more about all sorts of things: #365DaysOfScience All (with topics listed) 👉 bit.ly/2OllAB0 or search blog: thebumblingbiochemist.com
#scicomm #biochemistry #molecularbiology #biology #sciencelife #science #realtimechem
Especially if you load the same volume as your samples, doing this will help promote a consistent running front (avoiding artifacts like smiling, where the middle lanes run faster than the outer lanes, giving your bands an evil grin . . .)
You want to be strategic about where you put them – I like to put them in the edge lanes, between sets of samples, &/or next to highly-concentrated and/or viscous samples, which have a tendency to warp the neighboring lanes.
I recommend loading these “blanks” last – just in case . . . This way, you have backup wells in case you end up needing them (because of a loading error in one of the other lanes, etc.)
Note: 1X indicates that it’s at the working concentration. So for example, you might have a 4X sample loading buffer that you normally mix one volume of that with 3 volumes of sample (e.g., if you wanted to prepare 20 µL worth, you’d mix 20/4 = 5 µL loading buffer + 15 µL protein solution). For the blanks, in this case, you’d mix the loading buffer with water (or a buffer) instead of protein solution.
More tips on loading PAGE gels: youtu.be/8MCfiSiJDNU
More random practical lab tips & tricks: bit.ly/lab_tricks_page
more about all sorts of things: #365DaysOfScience All (with topics listed) 👉 bit.ly/2OllAB0 or search blog: thebumblingbiochemist.com
#scicomm #biochemistry #molecularbiology #biology #sciencelife #science #realtimechem










