This 3D animated walkthrough shows exactly how a home's air tightness gets tested using the Model 5 digital Minneapolis Blower Door System. Video is narrated by Steve Rogers from The Energy Conservatory.
Before any test begins, you have to set the house up correctly. That means closing exterior doors and windows, opening interior doors to create a single pressure zone, shutting off exhaust fans and combustion appliances, and prepping fireplaces safely. From there, watch how the aluminum frame, nylon panel, and fan get installed into an exterior doorway, and how a reference tube gets placed on the leeward side of the building for a stable baseline reading.
Once the house is ready, the video walks through how to actually run the test using the TEC Auto Test app — creating a project, choosing pressurization or depressurization, selecting a leakage target like ACH50, connecting the gauge and fan, and capturing baseline, open fan, and ramped pressure readings all the way to a shareable report.
With the test complete, you'll learn how to interpret the results: what CFM50 and ACH50 actually measure, why ACH50 normalizes leakage across different home sizes, and how stack effect, wind, and duct leakage drive air movement through a building's envelope. It also covers a critical safety note on repair order — why sealing lower-level leaks before addressing attic leaks can increase the risk of combustion appliance backdrafting.
Whether you're testing for new construction code compliance, diagnosing comfort complaints, or gathering data for a Manual J load calculation, this video covers the full process from setup to final report.
Find out more: energyconservatory.com
---
NEXT VIDEO
Measuring Duct Leakage To Outside
youtube.com/watch?v=FtPWajjm1Q0&t=438s
KEEP LEARNING
Start here:
hvacrschool.com/start
Free HVAC/R training, tech tips, quizzes, calculators, courses, and more:
hvacrschool.com
Listen to the HVAC School podcast:
hvacrschool.com/podcast
Get the HVAC School app:
hvacrschool.com/apps-page
HVAC School provides free HVAC/R training—primarily for techs, by techs. The goal is not just to collect facts. It is to understand the system well enough to apply what you know in the field.
Questions or corrections? Leave a comment and include the equipment model, measurements, and source when you can. None of us gets everything right, and good measurements beat confident guesses.
This content is educational. Follow manufacturer instructions, use proper PPE and safe work practices, and comply with the codes and standards that apply to your equipment and jurisdiction.
This 3D animated walkthrough shows exactly how a home's air tightness gets tested using the Model 5 digital Minneapolis Blower Door System. Video is narrated by Steve Rogers from The Energy Conservatory.
Before any test begins, you have to set the house up correctly. That means closing exterior doors and windows, opening interior doors to create a single pressure zone, shutting off exhaust fans and combustion appliances, and prepping fireplaces safely. From there, watch how the aluminum frame, nylon panel, and fan get installed into an exterior doorway, and how a reference tube gets placed on the leeward side of the building for a stable baseline reading.
Once the house is ready, the video walks through how to actually run the test using the TEC Auto Test app — creating a project, choosing pressurization or depressurization, selecting a leakage target like ACH50, connecting the gauge and fan, and capturing baseline, open fan, and ramped pressure readings all the way to a shareable report.
With the test complete, you'll learn how to interpret the results: what CFM50 and ACH50 actually measure, why ACH50 normalizes leakage across different home sizes, and how stack effect, wind, and duct leakage drive air movement through a building's envelope. It also covers a critical safety note on repair order — why sealing lower-level leaks before addressing attic leaks can increase the risk of combustion appliance backdrafting.
Whether you're testing for new construction code compliance, diagnosing comfort complaints, or gathering data for a Manual J load calculation, this video covers the full process from setup to final report.
Find out more: energyconservatory.com
---
NEXT VIDEO
Measuring Duct Leakage To Outside
youtube.com/watch?v=FtPWajjm1Q0&t=438s
KEEP LEARNING
Start here:
hvacrschool.com/start
Free HVAC/R training, tech tips, quizzes, calculators, courses, and more:
hvacrschool.com
Listen to the HVAC School podcast:
hvacrschool.com/podcast
Get the HVAC School app:
hvacrschool.com/apps-page
HVAC School provides free HVAC/R training—primarily for techs, by techs. The goal is not just to collect facts. It is to understand the system well enough to apply what you know in the field.
Questions or corrections? Leave a comment and include the equipment model, measurements, and source when you can. None of us gets everything right, and good measurements beat confident guesses.
This content is educational. Follow manufacturer instructions, use proper PPE and safe work practices, and comply with the codes and standards that apply to your equipment and jurisdiction.