Uploaded October 2026 | Updated November 2026, 3 hours ago
Watch the full playlist: youtube.com/playlist?list=PLbCk9hRe-ziGjenA7YPBEOTlvsxuc8V-q&si=vqchmqS_uFstnQJ9
Looking for the best NI thermocouple module for CompactDAQ or CompactRIO? This thermocouple measurement hardware guide compares NI C Series temperature input modules—including the NI-9210, NI-9212, NI-9213, NI-9313, and NI-9214. The video also covers temp measurement with other hardware families such as multifunction DAQ devices, FieldDAQ, and PXI. Brett explains how to choose thermocouple data acquisition hardware based on measurement accuracy, channel-to-channel isolation, channel density, sample rate, connectivity, ruggedness, and cost per channel. See the modules and accessories up close and learn which NI temperature measurement device best fits your test and measurement system.
0:00 Intro
0:36 Decision criteria
1:20 NI-9214 for accuracy and density
3:13 NI-9212 for accuracy and Ch-Ch isolation
4:53 NI-9210 for NI’s lowest cost thermocouple module
5:38 NI-9213/9313 for the lowest cost per channel
7:54 Quick selection table (screenshot this)
8:33 Multipurpose devices that measure thermocouples
9:25 FieldDAQ for rugged specs
9:56 PXI thermocouple measurement device
10:20 Software support
⚙️ Check these helpful resources:
NI-9214 for accuracy and density bit.ly/4j3cZjG
NI-9210 for NI’s lowest cost thermocouple module bit.ly/4y9imSm
NI-9212 for accuracy and Ch-Ch isolation bit.ly/4hEl0cw
NI 9213 for price per channel and 75 S/s rate bit.ly/3VA0UZw
bit.ly/47Hv8wk
Watch the full playlist: youtube.com/playlist?list=PLbCk9hRe-ziGjenA7YPBEOTlvsxuc8V-q&si=vqchmqS_uFstnQJ9
Looking for the best NI thermocouple module for CompactDAQ or CompactRIO? This thermocouple measurement hardware guide compares NI C Series temperature input modules—including the NI-9210, NI-9212, NI-9213, NI-9313, and NI-9214. The video also covers temp measurement with other hardware families such as multifunction DAQ devices, FieldDAQ, and PXI. Brett explains how to choose thermocouple data acquisition hardware based on measurement accuracy, channel-to-channel isolation, channel density, sample rate, connectivity, ruggedness, and cost per channel. See the modules and accessories up close and learn which NI temperature measurement device best fits your test and measurement system.
0:00 Intro
0:36 Decision criteria
1:20 NI-9214 for accuracy and density
3:13 NI-9212 for accuracy and Ch-Ch isolation
4:53 NI-9210 for NI’s lowest cost thermocouple module
5:38 NI-9213/9313 for the lowest cost per channel
7:54 Quick selection table (screenshot this)
8:33 Multipurpose devices that measure thermocouples
9:25 FieldDAQ for rugged specs
9:56 PXI thermocouple measurement device
10:20 Software support
⚙️ Check these helpful resources:
NI-9214 for accuracy and density bit.ly/4j3cZjG
NI-9210 for NI’s lowest cost thermocouple module bit.ly/4y9imSm
NI-9212 for accuracy and Ch-Ch isolation bit.ly/4hEl0cw
NI 9213 for price per channel and 75 S/s rate bit.ly/3VA0UZw
bit.ly/47Hv8wk










