In this video, Michael from Alarm Grid shows you how to set a local smart scene using sunrise or sunset as a trigger on a Honeywell Tuxedo Keypad Z-Wave Controller. Being able to create smart scenes with time-based triggers of your local sunrise or sunset is only possible when building the scene locally at the Tuxedo Keypad. If you try to make the smart scene remotely through Total Connect 2.0, then sunrise and sunset trigger options will not be available. This makes the local scenes slightly more valuable, and you may want to save some for use with sunrise or sunset triggers. For reference, the Tuxedo Keypad supports ten (10) local scenes and twenty (20) remote smart scenes through Total Connect 2.0.
A smart scene will have one or more predetermined actions occur automatically when a trigger takes place. The trigger could be something like arming or disarming the system or faulting a certain sensor on the system. You can even set a condition that will tell the smart scene to only go through if a certain prerequisite is validated when the trigger occurs. For example, you might have a smart scene that occurs at sunrise or sunset, but only if your system is in a disarmed state. In other words, in that hypothetical example, even if a time-based trigger of the sunrise time or sunset time occurred, the smart scene wouldn't occur if the system was armed away or armed stay based on the optional condition that was set.
alarmgrid.com/faq/why-can-t-i-create-a-scene-on-the-tuxedow-or-tuxedowc-using-sunr
http://alrm.gd/get-monitored
In this video, Michael from Alarm Grid shows you how to set a local smart scene using sunrise or sunset as a trigger on a Honeywell Tuxedo Keypad Z-Wave Controller. Being able to create smart scenes with time-based triggers of your local sunrise or sunset is only possible when building the scene locally at the Tuxedo Keypad. If you try to make the smart scene remotely through Total Connect 2.0, then sunrise and sunset trigger options will not be available. This makes the local scenes slightly more valuable, and you may want to save some for use with sunrise or sunset triggers. For reference, the Tuxedo Keypad supports ten (10) local scenes and twenty (20) remote smart scenes through Total Connect 2.0.
A smart scene will have one or more predetermined actions occur automatically when a trigger takes place. The trigger could be something like arming or disarming the system or faulting a certain sensor on the system. You can even set a condition that will tell the smart scene to only go through if a certain prerequisite is validated when the trigger occurs. For example, you might have a smart scene that occurs at sunrise or sunset, but only if your system is in a disarmed state. In other words, in that hypothetical example, even if a time-based trigger of the sunrise time or sunset time occurred, the smart scene wouldn't occur if the system was armed away or armed stay based on the optional condition that was set.
alarmgrid.com/faq/why-can-t-i-create-a-scene-on-the-tuxedow-or-tuxedowc-using-sunr
http://alrm.gd/get-monitored







![VISTA 128BPT: Programming a Wireless Zone
In this video Griffin from Alarm Grid shows the user how to program a wireless receiver and then a wireless zone into a VISTA-128BPT panel. The steps to program a VISTA-250BPT are exactly the same. Resideo and Alarm Grid recommend using address 07 for your first RF receiver. The VISTA-128BPT can support up to two (2) receivers per system.
To address a 5881-style receiver to address 07, set dip switches 2, 3, and 4 to ON. Connect the receiver to the panels keypad bus. Enter programming (Installer Code + 8 + 000, default code is 4140) and press [#] or [*] + 93 to enter menu-driven programming. You will be prompted with several options before you reach Device Programming. Press 0 for No on each of these options. At Device Programming? Press 1 for Yes. When prompted for the device address, enter 07 and press [*].
At device type, enter 03 for RF Receiver and press [*]. At RF House Code, if you arent using any bi-directional devices such as the 5828, 5828V, or 5804BD, or 5804BDV, then you can leave this setting at 00 and press [*]. If you are using bi-directional devices, just be sure the House ID entered here matches the House ID you program into your other devices. Press [*] and you will be back at Enter Device. Press [00] [*] and at the Quit Menu Mode? prompt, press [1] + [*].
Press [#] or[*] + 93 again and this time at the Zone Programming prompt, enter 1 for Yes. Enter the zone number you wish to program then press [*]. A little-known fact is that you can program any zone as a wireless zone, even zone numbers 1 - 9. The only zone you cant program as a wireless zone is zone number 64. This is reserved for low battery supervision for wireless keypads. To move through the prompts, press [*] to move forward. If you need to return to the previous prompt, press [#]. Program the zone based on your needs, following the information shown in the video. There are a lot of options in zone programming, and some of them are only shown if you program certain prerequisites first. For that reason, we wont go into all the details here. When in doubt, refer to the FAQ linked below or the Program Guide for the VISTA-128BPT.
After you view the final summary screen, at the end of the programming for your zone, press [*] and you will be back at the Enter Zone Number prompt. If you are finished with zone programming, enter [000] + [*] and you will shown the Quit Menu Mode? prompt. Press [1] and youll be back in regular non-menu programming. Press [*] + 99 to exit programming. Be sure to test any new zones youve programmed.
https://www.alarmgrid.com/faq/how-do-i-program-a-wireless-zone-on-a-vista-128bpt
https://www.youtube.com/watch?v=vnU8vnzkg6I VISTA 128BPT: Programming a Wireless Zone](https://i.ytimg.com/vi/vnU8vnzkg6I/mqdefault.jpg)