David Savery Electrical ServicesFollowing on from our unboxing and dead testing, this last episode in our three-part mini drama sees us using the TIS MFT Eco for some live testing shenanigans.
Chapters: 00:00 Ze 03:33 Zs 11:44 RCD 16:47 Other tests 17:06 Help screens
Errata: At 2:07 we record the fault current (PFC) taken as part of the Ze test. The PFC should be measured with the main earth reconnected to the MET of course as you do want any parallel paths included. Parallel paths have the potential to raise the fault current by reducing the external impedance. A typo on my Excel schedule of test results: the IR column should show MΩ as the units, not Ω. At 12:30, I say the RCD tests should be run for Type AC and Type A if you have a Type A device, however BS7671 only requires verification of the AC function and that's the result to be recorded. If you use an MFT to run other tests beyond what 7671 requires (Type-A, Type-B, Type-F), the numbers may come back differently, however that may be permitted depending on how the MFT performs the test and the product testing requirements of the device. If it passes the AC tests but appears to fail under different testing functions, seek advice from the manufacturer support line before writing the device off as a failure. More information on this can be found on eFixx here: youtube.com/watch?v=CqQfN3-nf4s
This video is subject to the same lengthy disclaimer that can be found in video 2: Dead Testing.
Live testing with Amy the SparkDavid Savery Electrical Services2021-09-03 | Following on from our unboxing and dead testing, this last episode in our three-part mini drama sees us using the TIS MFT Eco for some live testing shenanigans.
Chapters: 00:00 Ze 03:33 Zs 11:44 RCD 16:47 Other tests 17:06 Help screens
Errata: At 2:07 we record the fault current (PFC) taken as part of the Ze test. The PFC should be measured with the main earth reconnected to the MET of course as you do want any parallel paths included. Parallel paths have the potential to raise the fault current by reducing the external impedance. A typo on my Excel schedule of test results: the IR column should show MΩ as the units, not Ω. At 12:30, I say the RCD tests should be run for Type AC and Type A if you have a Type A device, however BS7671 only requires verification of the AC function and that's the result to be recorded. If you use an MFT to run other tests beyond what 7671 requires (Type-A, Type-B, Type-F), the numbers may come back differently, however that may be permitted depending on how the MFT performs the test and the product testing requirements of the device. If it passes the AC tests but appears to fail under different testing functions, seek advice from the manufacturer support line before writing the device off as a failure. More information on this can be found on eFixx here: youtube.com/watch?v=CqQfN3-nf4s
This video is subject to the same lengthy disclaimer that can be found in video 2: Dead Testing.
For web hosting, get £10 off at Krystal with the code DSESELECTRIC at checkout! krystal.uk
This content is not sponsored.Prats in a flat (with impressive length)David Savery Electrical Services2022-11-27 | Longer and stronger than a roll of Andrex, and about as much fun to stare at for an hour and a half: it’s us! In a flat. Doing stuff. Crikey, even the video description is boring!
Additional wiffle and disclaimers:
A couple of people contacted me after the English Kinetic Garden video to say they’d found the Ener-J products to be problematic. That video, and the start of this one where we again use Ener-J stuff, were both filmed on the same day which is why we’re seen using it again without comment. We’ve plumped for the Ener-J gear because that’s what CEF have off-the-shelf, and it’s a case of so far, so good. We’ll have to watch this space when it comes to long term reliability.
When I talk of LOT 20 around the 5:40 mark, I don’t mean it this legislation was brought in just for storage heaters, more that it’s storage heaters that fall foul of it to a greater degree than other space heating appliances because it makes new units more expensive, harder to control and harder to retrofit.
The appearance of Jamie “Information Torpedo” at 1:15:40 endorsing Unilite products was a clever deepfake. I’m sorry if it fooled you. In reality, Jamie curls up into a ball and sobs quietly if exposed to Unilite products.
The Smiler roller coaster at Alton Towers; footage courtesy of Attraction Source: youtu.be/Sx1y5qsJih8
For a shout out on the next video and to help cover the cost of washing Nigel’s sick out of my clothes, you can pony up for a pint of Persil Automatic here: buymeacoffee.com/dseselectric
Upgrading my wank hot water tank: youtu.be/B2o3kYKkc2UFailed RCD autopsyDavid Savery Electrical Services2022-11-03 | A pointless post-mortem perhaps, but after twenty plus years of faithful service, this Hager RCD has given up the ghost. Let’s slice it open with my high-end surgeons' tools (a laughable Woolworths Dremel knockoff and a hammer), and we'll take a peek at what’s going on inside its guts. You know, for fun!
Affiliate links:
For a shout out in a future video and to assist with the watery ending of this one, you can buy us a mop, bucket and/or towel here: buymeacoffee.com/dseselectric
Kip Hakes' YouTube nonsense: www.youtube.com/c/kiphakesSomeone signed this off... #shortsDavid Savery Electrical Services2022-10-29 | Don't worry, I (probably) won't poison this channel with these Shorts sharts, however while on site this week we came across one of the worst examples of workmanship we've seen in ten years, and yes, there was an Electrical Certificate for it, one which, under 'Comments on Existing Installation', the words "Very good" has been penned, presumably ironically. There may be more on this duff installation in a future long form video (as things bally well ought to be), but for now, I'll just poo this out on my Friday night and go back to drinking.In an English kinetic gardenDavid Savery Electrical Services2022-10-23 | Where better to spend a sunny autumn afternoon than in an English country garden? Well, in an English country pub is perhaps the natural answer to that, especially if there’s a busty barmaid a generous happy hour and no noisy Sky Sports feed. Sadly, we’ve not been called out to any such establishment lately; instead, it’s this garden which has a lighting problem we now need to resolve, and we're going to do it using a kinetic switch!
We’ve been out to this property several times in the past for various work, indoors and out, however the floodlights shown here aren’t ours. This SWA and lighting installation was put in by persons unknown sometime in the past. Some sections have already been wholly disconnected after external influences did their thing, but is what remains still okay? If so, what’s bally well stopping it all from lighting up?
I’m sorry the coffee shoutouts are so behind at present. It’s caused by several videos being in edit that are delayed for various reasons leaving us rather behind the times. Rest assured; we’ll catch up with the contributors eventually!
We mention Ideal connectors in this one, and yes, a Wago was also used. We’re affiliated with neither and use both. We thought we’d plug Ideal here just to show Wago aren’t the be-all-and-end-all.
Affiliate links:
The Acegoo remote switch we’ve fitted without issue numerous times over the past couple of years: amzn.to/3smEEjT
For a shout out in a future video you can buy us a sausage sandwich here, but for goodness sake butter the damn thing will you: buymeacoffee.com/dseselectric
For web hosting, get £10 off at Krystal with the code DSESELECTRIC at checkout! krystal.ukUpgrading my wank hot water tankDavid Savery Electrical Services2022-10-16 | What’s that you say? You want a boring video about a water heater featuring a plumber and just enough male nudity to get it demonetised? Well, you’re in luck friend, because I have just the thing for you right here. So, pull up the blankets, grip the hot water bottle and let uncle David send you off to sleep… albeit perhaps not too soundly.
Personally, I can’t believe I found a good use for Nigel’s head in this one, but it does actually work rather well as a virtual loincloth. Who knew?
I know it’s been a while since the last upload; September placed a few demands on my personal time which precluded me from faffing about with the video editor, but other stuff will be forthcoming as autumn ambles along. Sorry too if you’re patiently waiting for your coffee shoutout. We recorded one on 19th August for our I.R.SEHOLES video, then this one on the 24th, but many more have landed since then. Rest assured; your time will soon come; more is in edit right now!
I (somewhat mistakenly) refer to it more than once as an instantaneous water heater… which it isn’t. It doesn’t heat on demand; it maintains a small-(ish) 30 litre tank. When that’s been drained, it’s gone mate, and I’ll jolly well have to wait for it to re-heat a whole new tankful from cold. What it does do is take up less space, delivers better pressure and it maintains the warm water more efficiently than the old tank.
The energy monitor shown in this video will (supposedly) feature in another one which is partly recorded and talks more about its construction and purpose. For anyone interested, it can be found at this affiliate link: amzn.to/3fNAOgF
This video was originally only half an hour long and was supposed to go out last Tuesday, but then I decided to complicate my life by adding about a million slides describing how immersion heaters work, hence the discrepancy at the 45-minute mark where I say it’s only been thirty minutes long and was useless. Now it’s much longer, albeit still useless.
Oh, and no, I don’t ordinarily sit down to wee out the Carlsberg; it was just practical here as I waffled to the camera. That said, perhaps I should as sometimes when assuming the upright pose the spray goes simply everywhere! You know how it is, right fellas? I especially feel guilty when it jets off at an impossible angle and somehow sprinkles in foamy golden droplets over the wife’s toothbrush, but I dare not tell her that happens… or how often.
I’m sure I speak both for myself and for you out there watching by saying we’ve all personally experienced this many a time… I certainly have.
For a shout out on a future feature and to keep me and Nigel in hot coffee rather than hot water, you can buy us a beverage here: buymeacoffee.com/dseselectric
For web hosting, get £10 off at Krystal with the code DSESELECTRIC at checkout! krystal.ukPair o I.R.SEOLESDavid Savery Electrical Services2022-08-27 | Just a few days after we installed a swish new RCBO board in our last video and one of the circuits is already tripping off! What gives? A fishing expedition with an I.R. tester ought to point us in the right direction.
Apologies for the 2018 camera work in a flashback segment – that was a job we captured on whatever shaky mobile phone we had with us at the time as it was before we started vlogging the day job, so the quality sucks and, yes, Nige did look like a freak with his short hair and long beard. Like a fine cheese, he gets better with age… up to a point. Eventually he’ll just turn blue and smell like feet.
On that job, if I remember rightly, the shower was earthed via the water bonding, but its copper pipe wasn’t in contact with the damp wall as it passed through the hole. The rail was in contact with the damp parts via its screws, and the sink taps via their copper pipes which were attached to the wall before joining onto plastic pipework (islanding them from the water bonding). Thus, when the old immersion cable was compromised in the wall, it made the damp section live along with any metalwork bolted onto it. If you touched the shower and tap, you got 180V straight across your nipples.
Affiliate links:
For a shout out on an upcoming video and to keep me and Nigel in unhealthy habits, you can buy us a cigar here: buymeacoffee.com/dseselectric
For sweary sparks, Jamie Blatant’s Information Torpedo channel is here: youtube.com/channel/UCduaH-Au7koVBVwj_5f1OSA/featuredOh FFS, its another board change videoDavid Savery Electrical Services2022-08-13 | Yes, yes, it’s been done a thousand times before and a thousand times better no doubt, but we had the camera with us and the run of the place, so figured it wouldn’t hurt to show another old CU coming out and a shiny SBS beauty going in. Oh, and Nige managed to find an insulation resistance fault too, so there’s that.
Afterwards, on the van, Nige came to the realisation that not all numbers are an integer and that it’s possible for fractions of numbers to exist. Who knew? Apparently, not he… until he saw someone talking about it on YouTube. I guess you live and learn.
The shout-outs are about as long as the electrical content in this one because I let them build up too much following a delay in releasing the last video about extractor fans. But, meh. It’s not like you have to watch any of it.
For a shout out on a future video and to keep me and Nigel puffing away, you can buy us a cheap machine-rolled supermarket cigar here: buymeacoffee.com/dseselectric
For web hosting, get £10 off at Krystal with the code DSESELECTRIC at checkout! krystal.ukFan fault finding, fixing & fidgetingDavid Savery Electrical Services2022-08-07 | It’s a wordy video about domestic fans. What’s not to like? Well, plenty perhaps, but never fear, there are four chapters to help you navigate this piffle:
00:00 INSPECTOR FANNY: A closer look at an industrial duct fan and the tickling of its run capacitor.
07:27 TWO’S UP ONE DUCT: A switching arrangement to allow one fan to serve two rooms.
13:36 TIME CRISIS: A comparison of external timer operations with, perhaps, a surprise in store for anyone trying to stick too many fingers up the thing when it’s not so warm and welcoming.
31:44 IT’S A BLOODY FIX!: The repair of a duff Vent-Axia VASF-100T timed fan.
This video is an example of something that started off as being fairly simple but grew in complexity when it transpired the timer I’d sourced acted in a way I didn’t expect, along with my happened to be called out to a faulty Vent-Axia that same week. What I thought would be a quick one to knock out of the ol’ PowerDirector toaster has, through feature creep, grown into something of a monster for filming and editing.
That also explains the delayed beer shout-outs which were recorded Friday 29th July in anticipation of this being published that weekend. My apologies if you’ve generously donated to the cause since then, rest assured another (simpler) video is in edit and you will get your shout in the coming days when that one plops off the production line and lands in a wet pile in your lap!
Errata: When talking about the relay, I say it has in-built diode protection against back-EMF. This is incorrect; the legend shown on the relay casing is for the LED indicator as pointed out by Steve of the @SDG Electronics channel.
For a shout out on a future video and to keep me and Nigel ensconced in our coffee hole, you can buy us a slug o’ joe here: buymeacoffee.com/dseselectric
For web hosting, get £10 off at Krystal with the code DSESELECTRIC at checkout! krystal.ukDeciphering a duff EICR... with THIS GUYDavid Savery Electrical Services2022-07-30 | In this (admittedly somewhat disjointed) vlog, Me Nige and this other guy go poking around a recent CU upgrade by a rival local firm which they backed up with a “satisfactory” condition report. But are things really tickety-boo here, or are there a few obscure oddities, queer quirks and downright dangers lurking behind the wallpaper?
Background brah…
The Verso consumer unit was installed by another local firm in February 2022 and the only paperwork left on site was an EICR with mislabelled circuitways, erroneous data and no mention at all of DB2 in the kitchen. Of note is that the inspection and testing label on the new CU matches the date on the EICR which makes us think it all took place on the same day. Consider that it took three of us the best part of a day just to figure out what went where and to get some test data out of it all, I doubt that one or two people could have performed a diligent effort in inspecting, testing *and* upgrading the installation in a single day which perhaps explains why the paperwork is so poor. These guys, it seems, turned up figuring it would be a straight CU change and perhaps bit off more than they could chew before they took the money and scarpered.
The EICR, which they are not accredited with NICEIC to even author, also shows no limitations and claims 100% of the installation was inspected and tested. Bold claims for a report which omits DB2 entirely as well as a lighting circuit and the SPD OCPD on the very consumer unit they themselves have just installed!
When we first visited the installation in July, we asked to see the certificate paperwork, however the EICR was all the homeowner had. We told them to chase their contractor for the EIC & Part-P and these were sent through a few days later (about two days before we arrived and filmed this). The Part-P is supposed to be issued within 30 days of completion of work. Had we not intervened, this paperwork would have stayed absent no doubt, but the EIC is nonsense anyway as it’s just been lifted from the EICR which is itself error laden.
DB2 serves lights and sockets on the short rear extension of the property (lounge and kitchen). Lights and sockets elsewhere are all off what appears to be a short ring circuit that’s original to the house, with the lights for each floor fused down locally. I say in this video that I concur with the EICR numbers, what I really mean is I agree that the ring end-to-end readings are unexpectedly low. The numbers our predecessors have recorded play out by the book with r2 being 1.67 times higher than r1, and R1+R2 being the sum of (r1+r2)/4. In reality, our readings were a little higher with r2 being slightly out of whack and R1+R2 being much higher than the maths suggests; entirely expected on an installation that clearly has spurs off spurs and which also serves lighting on a downgraded cable. On their EICR, it’s clear the ring end-to-end testing was performed, then the rest of the data was made up from calculation instead of being obtained by testing.
The RCBO in circuitway 6 of the new CU served the lounge wall lights only and was a perfectly serviceable circuit outside of the fact it had been cross connected to the lounge lights on the adjacent switch which we found comes off the ring circuit. That wouldn’t have bothered the old BS3036 board, but obviously caused tripping in the new RCBO arrangement. Rather than investigate why the wall lights were causing tripping, which would have involved disconnecting two light switches to immediately spot the problem as we did, they simply left the wall lights disconnected, left the homeowner with the impression that there would be a bang if they pressed the switch, and charged for the installation of an RCBO that did nothing.
Having taken the sockets off, we determined few outlets were on the ring and original to the house, the rest had been spidered off as spurs off spurs off spurs over the following decades. Ordinarily, we’d drop the circuit down from 32A to 20A, but this is serving the oven, fireplace, lighting and most sockets including the main body of the kitchen, so the only real fix is to pull in new cabling partially or wholly to remove the loading.
Wander lead testing allowed for a quick check of earthing at the Class 1 lights which determined a break in the CPC at the bathroom, bedroom light switch, small bedroom luminaire and dining room light. We used the wander lead to avoid disassembling some of the more awkward fittings to check for CPC continuity.
Sorry about my Monday morning hair. I washed it on Sunday and simply can’t do a thing with it. Oh, and I know there’s a typo in the on-screen title, but I’m not rendering this again. It takes ages in 4K!
For a shout out on a future video, you can buy us a beverage here: buymeacoffee.com/dseselectricNTT: The Megger MPU690 Multi-Voltage Proving UnitDavid Savery Electrical Services2022-07-19 | Who knew that today, the hottest day in the UK on record, there would be a video about a new proving unit I’d just blown about seventy beer tokens on? Not me. At least, not until I was standing in Edmundson’s yesterday looking at the claims on the box of this thing as it glittered in the locked display cabinet flashing its curves and pouting lustfully...
…I dunno, yesterday was also hot, and maybe I was dehydrated and experiencing some kind of mirage. Still, had I known it wouldn’t quite live up to the promises being pimped on the box, maybe I’d have kept my credit card safely tucked away in the pocket of my shorts where it rubs comfortingly against my wenus.
Not that this hardware is a bad thing; far from it, and those in the market for a proving unit could do a lot worse. Is it better than my old proving unit that cost much the same ten years ago and has a fixed Voltage output? Yes, certainly. Still, six batteries is something of a kick in the ghoulies – my whole MFT only takes eight! Also, I’m most smo that it doesn’t perform a proper and patient step-Voltage test.
I guess it gave me something to fiddle with, other than the usual, as I sat in a dark corner of my office with the sun beating down outside. It’s funny how it’s usually too hot in here, yet today 34C on the office thermometer feels cool compared to the blazing outside air. It’s certainly better than being out on the van, and no, that rusting Transit doesn’t have air conditioning.
My thanks to Nick Bundy for sending me the photograph of his circumcised end when I requested it via WhatsApp. After some minor misunderstanding was cleared up, he then sent me a picture of his TIS859 with the retractable shrouds lopped off. Yip yip!
For web hosting, get £10 off at Krystal with the code DSESELECTRIC at checkout! krystal.ukThe Fantasmic Sack of Cack Giveaway!David Savery Electrical Services2022-07-16 | Yo biatches, it’s our first and, perhaps, last ever competition giveaway and we have none other than electrical YouTube royalty to help us spaff it out into your faces.
No, it's not Tom Nagy… or Artisan Electrics. No, it’s not Chris from CJR or even the dreamy James Beck. What’s that? Jimbo the Electrician? Afraid not, but… wait, who? Delroy at Eastway Electrical? No, I’m sorry. Willmann Electrical you say? Sadly, not them either… oh for goodness’ sake, look, it’s Nick bloody Bundy okay?! Didn't you see the half arsed drawing of him in the thumbnail?
Crikey, that was hard work.
If you’ve quite finished interrupting, the giveaway bit is at the 11:50 mark after a load of boring and perfunctory waffle, but for terms and conditions, refer to this page on my website:
Nick says in this video that some of you fine folks don't like him, so prove the asshole wrong by saying nice things about him in the comments. That'll learn him!
My apologies to the likes of Armeg, Quickwire and Ideal for including their wares under this competition banner – their gear most certainly ain’t cack! In this case, the term is used as a catch-all for a diverse prize with some questionable elements as opposed to saying all this stuff is rubbish.
For web hosting, get £10 off at Krystal with the code DSESELECTRIC at checkout! krystal.ukVirtuaVan 360 ride-along... TO THE PUB!David Savery Electrical Services2022-07-13 | Yes, the future is NOW, so take a small step for mankind into the metaverse folks, and experience a virtual van ride-along with two suspicious chaps who, you fear, may have invited you into their van with the promise of some sweeties… or maybe seeing some puppies. Or something.
Don’t worry, you’re perfectly safe. We’re just off down to the Hungry Horse pub for a quick beer in the sunshine! Woohoo!
If you have a VR headset, you can all but smell my body odour and Nigel’s desperate overuse of Lynx Africa as you (virtually) get up close and personal to your two favourite electricians... Well, I say favourite as in not including Jordan and Corey of course. Or Nick and Adam. Or those Doctor Electric fellows...
..oh, enough! If viewing on a mobile device with a gyro, move your gizmo around to point your peepers in any direction, otherwise if on a TV or PC monitor, use your mouse or other peripheral of choice to swing your view around the place.
That curious pink squiggle above your head? It’s the Rode microphone cable atop the camera, but you can pretend it’s a hat. Or a UFO.
This was just a daft proof-of-concept with our new camera, and my apologies for the ISO(?) being set incorrectly so that not much was visible out of the windscreen. Maybe we’ll do another one in the future. Or maybe this gimmick has already massively outstayed it’s welcome?
This was filmed in 5.7K although I'm not sure YT supports that as it shows as 4K? Anyway, in resolution terms, this is as good as it gets for now. Easiest way to play it on a headset is to select it on a PC or mobile and add it to Watch Later so you can pick it up without typing in the link.
Spot the Nissan Note, current score: 5, 2 to David.
For a shout out on a proper video and to keep me and Nigel visiting the Hungry Horse on hot days, you can buy us a cool Carlsberg here: buymeacoffee.com/dseselectric
For web hosting, get £10 off at Krystal with the code DSESELECTRIC at checkout! krystal.ukNTT: Hioki 3490 Analogue MΩ HiTESTERDavid Savery Electrical Services2022-07-05 | What’s that, analogue you say? Analogue??! Surely in this world of digital test instruments there’s simply no value to something with a pointy pointer that points to printed pictures of poxy numbers?! Well, maybe… but surely all those pesky Australians can’t be wrong?!
Notes: At 5:51 I wibble on about aligning the needle through the centre of the infinity marks on the display, then after much twiddling I leave it cock-off. That’s just because the camera was in the way and I was looking at it from the side, but it goes to show how an adjustment of this sort needs to be made when facing it squarely on.
It’s also of note that I say the MFT1552 shows an electronic ‘analogue’ display ranging in voltage from 0 to 600, the latter number indicating full-scale deflection, yet the legend printed to the left of the Megger’s LCD shows no more than 500V should be applied… so that’s a bit weird and serves to make me look quite the fool.
I should also state that Megger, and the 15 or 17 series of testers, aren’t the only brand or models of digital instruments that show an analogue representation on their LCD displays. My TIS MFT Pro has such on IR, in a very basic way, and that cute Robin KTS1625 has a digitally represented scale too. Other machines have similar no doubt.
Oh, I know there's been a glut of new videos spouted out here over the past week which is most out of character. Rest assured, the next one may be weeks away!
For web hosting, get £10 off at Krystal with the code DSESELECTRIC at checkout! krystal.ukHalf a fault 2 : The odd switcherooDavid Savery Electrical Services2022-07-03 | Just to prove we don’t (always) know what on earth we’re doing and that things don’t always go as planned, here’s us stumbling to figure out the other half of the fault we found before Christmas. Curiously, while we’re there, the fault seemingly shifts from cabling that previously tested as bad to cabling that previously tested as good. Still, we found and bypassed *a* fault, if not perhaps *the* fault which we were looking at last time. On the day we were quite frustrated with how this was going and angrily threw the camera back into the bag as we went about trying to make sense of this one. This means some sections weren’t filmed, so some visual aids have been added to try and make sense of it all.
This should have gone out at the start of the year to be paired with the Half a Fault video that precedes it, but I wasn’t sure how I’d make sense of the edit seeing as we couldn’t figure out what was happening here and with some portions of the work having not been recorded. Last weekend however, I came down with COVID which has given me some time to get up to my elbows editing the bugger. Sorry for the croaky voiceover; symptoms are finally clearing up after a week!
For web hosting, get £10 off at Krystal with the code DSESELECTRIC at checkout! krystal.ukMy Big Phat Greek JunkDavid Savery Electrical Services2022-06-27 | You know, sometimes what one needs is a good holiday. Sun, sea, sand, sex… well, okay, three out of four ain’t bad, but instead of drunkenly getting away from it all under the blue skies of a Greek getaway, I somehow drunkenly ended up looking at some foreign fuse gear and rifling through my emails to see what spams, scams and utter nonsense has been cluttering up my inbox for the past few months.
You may also be pleased to hear that I finally coughed up for a new camera in time for this holiday, so say hello to 4K, image stabilisation and curious angles that my old camera could never manage even if I tied it in knots... although it does mean the sound is crap as the additional bits to attach it to my trusty Rode microphone didn’t arrive before I left home to face the misery of Birmingham airport’s departure terminal.
Links:
Surely the best electrician’s website in the world: dses.uk
Dave sent James Beck some of his stickers, and James forwarded some on to me which is why one now adorns a consumer unit on a Greek island far from home. I’m not about to get into any of that sticker trading that was doing the rounds a couple of years ago though – seems too much like office admin for my liking!
The text-to-speech conversion was performed by this site: https://www.texttovoice.online/
And yes, some voices were a little hard on the ears. Especially that bloody Chinese one.
For a shout out on the next video and to keep me and Nigel ensconced in our new secret coffee location, you can buy us a beverage here: buymeacoffee.com/dseselectric
For web hosting, get £10 off at Krystal with the code DSESELECTRIC at checkout! krystal.ukThe (ultimate) ultimate Electricians toolboxDavid Savery Electrical Services2022-05-24 | An impromptu video showing my shiny new toolbox and quick clip-on pouches, hastily knocked up after the day finished unexpectedly early.
For web hosting, get £10 off at Krystal with the code DSESELECTRIC at checkout! krystal.ukJuicing up Sams knobby French vanDavid Savery Electrical Services2022-05-22 | Back by popular demand is our man Sam Smith (no, not the famous one), and the silly sod’s only gone and bought himself an electric van! A French one too if you please! Aren’t builders all supposed to be a bunch of hairy-arsed Brexit voting xenophobes? The world’s gone mad I tells ya!
We performed some electrical work on Sam’s (oddly yellow) house back in 2018 where he asked us to pull in a cable quite late into the project just in case he ever wanted an EV chargepoint. We were able to tug in a cable from the CU to the outside wall by going under the floorboards upstairs, but it meant the bugger popped out at a high level which wasn’t ideal. Still, there wasn’t much else for it as the downstairs walls had been replastered by that point. We erroneously state on camera that it’s a 4mm cable, it was actually 6mm from the CU to the outside, although we pulled 4mm singles through the exterior conduit.
This was filmed either side of the Easter bank holidays and is edited out of sequence, hence any continuity observations that may be made between Nige and I seemingly swapping beards.
To save anyone asking, the new Type-A RCD we installed was rated at 100A to replace the 63A Type-AC we removed.
Nigel and I sat the C&G EV course way back in 2016, so we’re out of date on the current code of practice and on the technologies available out in the world. We’ve only ever installed a handful of EV points, mainly because the stupid OZEV scheme poisoned the market and made it tricky to compete. Perhaps we’ll brush up on it now that OZEV has been taken out back and shot in the face. Besides, I now have an expensive Ethos EV adaptor to earn its keep.
Megger’s new EVCC300 looks like a tidy bit of kit for those who undertake regular chargepoint testing, but that’s not me, so I won’t be getting my tit-squeezers onto one anytime soon: tester.co.uk/megger-evcc300-electric-vehicle-charger-checker
Chapters:
00:00 to 09:43 Merciless mickey-taking of Sam and his new electric van 09:44 to 16:12 Job talk and initial verification dead testing 16:13 to 18:39 Unenthusiastic unboxing of the Easee One Charging Robot 18:40 to 20:56 Physical installation 20:57 to 24:10 RCD testing 24:11 to 27:57 More physical installation and initial commissioning confusions 27:58 to 47:29 Chargepoint testing 47:30 to 51:33 Plugging the bastard in 51:34 to 52:41 ENA paperwork blarney 52:42 to end : Relentless piss-takery of poor Sammy.
For web hosting, get £10 off at Krystal with the code DSESELECTRIC at checkout! krystal.ukTactical nuke on Megger vs. FlukeDavid Savery Electrical Services2022-05-07 | As they say, variety is the spice of life. Favourite spice? I’d probably say Geri in *that* dress. What’s that, Baby Spice you say? Nah, you can keep her - I like a woman with curves: something you can plunge both hands into or stick your head between while making a loud raspberry noise... so to speak. Yeah, if all the Spice Girls trundled over to Whitnash and banged on my door beggin’ and pleading for some Savery saveloy, Geri’s the lucky one getting to wipe her big boots on the welcome mat. The rest will just have to cope with their disappointment and bob off for a little cry somewhere.
Mind you, at my age and having been married for 23 years, I doubt I’d know what to do with her. I’d probably bore her with my collection of multifunction testers just as I’m boring you all right now, then take her to the Hungry Horse pub for a couple of Carlsberg’s and a steak & ale pie from off the ‘two for £7.99’ menu.
But I digress, I meant to talk about variety, and when it comes to the world of multifunction testers, things don’t have to be as black and white as the age-old question of whether one simply plumps for a Megger *or* a Fluke. There are other options. When it comes to selecting an MFT, you should be sure to choose something that has the desired feature set for now and for the type of work you think you’ll be performing in the future. Brands such as Megger and Fluke command high prices; you’ll get something that does more but costs less if you look at lesser-known marques, although budget brands may have cut corners that affect robustness or reliability in the long term.
Anyway, this vid got cooked up after our Friday job was canned thanks to APC Overnight failing to deliver Tuesday’s order on Wednesday. Or Thursday. Or even Friday. Feckin’ courier firms – they have one job for frick’s sake, and when they don’t do it, I don’t get to do mine. Still, if they had done their job, I’d have been out earning money Friday afternoon and this nonsense wouldn’t exist. Every cloud and all that… if indeed the existence of this video is viewed as a positive thing…
For web hosting, get £10 off at Krystal with the code DSESELECTRIC at checkout! krystal.ukMy (rambling) view on amendment 2David Savery Electrical Services2022-04-24 | Yes, who doesn’t like listening to a monotone alcoholic drone on for an hour and twenty minutes about a subject everyone else has already covered (and with less profanity).
Sorry for the YT age restriction - it's something they impose, but meh. Whatever. Remember, all my content is available ad-free and restriction free on Odysee if you don't want to play by Google's rules: odysee.com/@dseselectric:e
I fully expected to get this out in the first week of the release of 18th Edition amendment 2 when it plopped onto my doormat nearly a month ago, but this has ended up being the most complicated and time-consuming video I’ve ever made with all the reading, scripting and over 250 visual, audible and back-end assets. Seeing as making videos isn’t my job, it’s had to swallow a lot of spare time.
Actually, this nonsense should have been out last week, but I got so drunk over Easter I just couldn’t work on it.
So, there you go. It’s a load of stuff you will already have heard by now, therefore there’s no point in watching it.
Chapters: Revised HSE Notice 4:13 New terms 11:36 AFDDs 12:59 SPDs 19:56 Split load boards & RCBOs 23:05 Type-A & Type-AC RCDs 26:27 BS7288 RCD accessories 29:31 RCD testing 30:44 IR testing 34:39 Model forms 36:56 Labelling and handover guide 46:26 Prosumer (bleugh) 53:31 Protected escape routes 56:01 Core colours 56:55 Sockets in bathrooms 58:14 Table 52.3 (power wiring CSA) 59:20 Outdoor lighting installations 01:01:50 Localised earthing 01:04:23 Epilogue 01:10:00 Buy me a Beer! 01:12:07
Links to the shiny things seen in this presentation (in no particular order):
The image of Rishi and Priti I nicked from Beta (I tried to seek permission by creating an account, but they never sent me the password confirmation): Beta image: b3ta.com/board/archive/43696 Image courtesy of the skillage of B3ta user Octo: b3ta.com/users/profile.php?id=38966
This will be the last name and shame I perform on any prick who wants a pop at me (with reference to the asshole I have a crack at in the BuyMeACoffee segment). This is for fear of encouraging deliberate duff comments just so I’ll read them aloud. Shout-outs are reserved for the "special" people who buy us a brew: buymeacoffee.com/dseselectric
For web hosting, get £10 off at Krystal with the code DSESELECTRIC at checkout! krystal.ukThe GIMPs room... #shortsDavid Savery Electrical Services2022-04-23 | An 'interesting' attic room we uncovered on an electrical inspection in August 2020. This video was originally uploaded to Twitter, but it lends itself to my shorts collection, so my apologies if you've seen it before.
We did make it out of there alive, we don't know what the curious blood stains on the wall were all about, and we've never been back since!
Several large videos are currently being worked on, so this is just a little short to remind the world we're still alive here.Bobbin a Robin onto the jobDavid Savery Electrical Services2022-03-27 | With my trusty TIS possibly in need of some TLC, I look at the logistics of pressing some old school Robin bling back into active service. Will kit last calibrated in 2007 still churn out the numbers expected? Is my TIS fault down to the instrument or the leads? Did I actually hand over hard cash for this Herman Munster haircut? Is Carlsberg really (probably) the best lager in the world? These answers need to be questioned before it’s too late, so pour a stiff one and join me on a freakin’ boring video with iffy autofocus and a whining noise on the microphone…
For web hosting, suck £10 off at Krystal with the code DSESELECTRIC at checkout! krystal.ukRemuneration from illuminationDavid Savery Electrical Services2022-03-26 | Hallelujah! I seeee the light! And praaaiiise be my brothers and sisters, for it shines bright in the form of a GU10 LED lamp in a fire-rated fitting which, the good Lord knows, if installed in place of those discoloured old 12V halogen nasties burning like Satan’s eyes in your unholy ceiling, will earn you back the cost of installation in energy savings alone. TESTIFY!
Yes, folks, this is one of those jobs that pays for itself – and in as little as under two years with today’s rocketing energy prices.
Speaking of bang-for-your-buck, I give a price breakdown later in this video which is based on the best-case scenario for this kind of job, i.e.,
We have access to the lighting junction at each point. The wiring and wider installation is fault-free. The existing holes don’t need resizing. The new fittings have loop in/out with provision for the CPC and no external junctioning requirement. Access is straightforward without needing specialist ladder or platform arrangements. It's not in an area classed by BS7671 as being a Special Location. Material costs are based on what I pay today for these component parts with my mark-up applied.
Where the job falls outside of the ideal criteria and additional work is needed, it will cost more and take longer to pay back.
For web hosting, get £10 off at Krystal with the code DSESELECTRIC at checkout! krystal.ukOld Geezers GearDavid Savery Electrical Services2022-03-06 | You’d think with that fruitcake in Russia determined to turn the world into a Mad Max-esque wasteland, there’d be better things to do with the day than to tune in to a couple of flatulent old white guys rubbing their trousers over test equipment that’s been shoved into a cardboard box at the back of a dark n’ dusty cupboard for the past twenty years. But here you are… and, frankly, I question your life choices.
Affiliate links:
For a shout out on the next video, assuming we all survive the oncoming armageddon, you can buy us a beer here: buymeacoffee.com/dseselectric
For web hosting, get £10 off at Krystal with the code DSESELECTRIC at checkout! krystal.uk
For anyone likely to ask, my latest oddball mobile phone is a Unihertz Titan Pocket thing.A Shade BrownerDavid Savery Electrical Services2022-02-27 | Nigel and I take a peek at a PV installation stapled onto someone’s home by A Shade Greener. I should point out that I’m not saying A Shade Greener are in any way iffy or that they perform inadequate installations, however I am stating the obvious fact that their installations often are, like many others, done to a budget and a timeframe which is not in sympathy with the aesthetic many people would accept for work on their homes.
My own PV installation, on a property A Shade Greener erroneously dismissed as being unsuitable for such, has no cables on show anywhere outside of the attic, whereas here we find an SWA zig-zagging down the front wall of the house adjacent to the main entrance, consumer equipment in the meter box where it demonstrably isn’t supposed to be, the supplier seal cut which *must* have happened when the PV went in as the old CU has clearly been there for a looooooong time, and the PV meter being in an awkward location for the odd occasion where it needs to be read, not to mention the more common occasion where you want to know the friggin’ installation is still working and isn’t borked!
For web hosting, get £10 off at Krystal with the code DSESELECTRIC at checkout! krystal.ukThe ultimate badass T&I labelDavid Savery Electrical Services2022-02-13 | BS7671 amendment 2? Pah! Another whitewash to sell us all a new regs book. Expect nonsense and daftness, but don’t expect fixes to things that have been broken forever… like the humble inspection and testing label.
Perhaps time then to take matters into one’s own hands. Meh, they’d only be stuffed down the front of one's own trousers anyway.
And yes, I know inspection precedes testing so it should really be the I & T label, but we all tend to say "test and inspect" as a phrase as T&I rolls off the tongue slightly more naturally than I&T.
For a shout out on the next video and to keep me and Nigel in a drunken stupor, you can buy us a beer here: buymeacoffee.com/dseselectric
For web hosting, get £10 off at Krystal with the code DSESELECTRIC at checkout! krystal.ukTwo pricks visit NicksDavid Savery Electrical Services2022-02-02 | What happens when you lock three men and a young boy in an industrial unit deep in the ass-end of Stafford? Sounds like a Jimmy Saville BBC special from 1979, but in this case it’s just a waste of time as men do what men do when cooped up together. They set something on fire, break wind and someone ultimately gets walloped.
So, nothing new here, and certainly nothing electrical or entertaining. Look away if you’re expecting anything other than twenty-odd more minutes of your life pointlessly wasted. Although… well, be honest, what else would you do with that time outside of PornHub anyway? Didn't your mother ever tell you it would drop off if you kept fiddling with it??
I have to admit, I pressured Nick on the whole making an ingot thing, so it’s my fault the full range of PPE may (or may not) have been present on the day (I honestly don’t know what PPE is even required), so assume the alternate title of “Pricks Taking Risks” and don’t try doing the same at home.
Our thanks to Nick and Adam for their hospitality even though I had to pay twelve quid to use the M6 toll to get there, it cost me half a tank of diesel and they didn’t even buy the sausage n’ egg sandwich I went and fetched for lunch. Still, we got a stupid ingot out of ‘em, stole a few Knipex tools when they weren’t looking and left their toilet in a right royal state, so all’s even I figure.
I apologise for some auditory arsehole, we only had one microphone between four of us and, although none of us had anything useful to say, the rubbish that was spouted forth was a bit up and down in places. I meant to level the audio but I had one too many and plum forgot.
Nick may have a video on his channel in the coming days, if indeed there was anything more salvageable he picked up on his camera. Frankly, I doubt it.
For a shout out on the next video and to keep me and Nigel oiled and lubricated, you can buy us a beer here: buymeacoffee.com/dseselectric
For web hosting, get £10 off at Krystal with the code DSESELECTRIC at checkout! krystal.ukNew CU with STAR CELEBRITY GUEST!David Savery Electrical Services2022-01-03 | Clench your buttocks and pucker up your sphincter in anticipation of the mystery celebrity guest joining me for yet another flimmin’ video half showing a consumer unit change and the replacement of some downlights… which we largely neglect to film despite yapping about it.
Who could it be? The chumminess of Delroy at Eastway Electrical? The genius of Joe Robinson? That Mike kid from the Residual Current channel who already sounds like he’s forgotten more than I’ll ever know??
Since we filmed this last year, SBS have launched a swish new website where you can register for a trade account and order spare parts or configured consumer units at sbstradesales.co.uk so if you’re a bona fide spark you may as well go open a trade account!
Eagle eyed viewers may spot at the 49:00 mark that there is a mislabelling on the consumer unit as some idiot misaligned the main switch label over the SPD. Pah!
My apologies, for all the talking in this video, there seems to be precious little showing the CU installed or any of the downlights going in. As electricians, our filmmaking skills are probably similar in quality to a filmmaker's electrics.
Links: South Manchester Electrical, heroes of the piece: southmancelec.co.uk James Beck’s tester test off: youtu.be/BXbR-ePUaJA The Jamhamster channel whose music I keep nicking but who doesn’t respond to my messages asking for permission or my offering to split any advertising revenue: www.youtube.com/c/jamhamster
Whaddya mean you don’t remember Bod and don’t get the reference? youtu.be/B4IiktFp3p4 - kids TV was a lot simpler in the Seventies.
Affiliate links:
Klein NCVT-6 laser measure and non-contact voltage detector: amzn.to/32XgqAX ...which in no way looks like a dog’s cock (not that I’d know or got the chance to find out).
For a shout out on the next video, if this one hasn’t put you off, and to keep me and Nigel juiced up, you can buy us a coffee here: buymeacoffee.com/dseselectric
For web hosting, get £10 off at Krystal with the code DSESELECTRIC at checkout! krystal.uk
For anyone likely to ask, my weird phone is a Cosmo Communicator from Planet Computers: www3.planetcom.co.uk/cosmo-communicator It has its flaws, but for someone who loved their Psion in the 1990s, this is as close as one can get to that form factor.Half a faultDavid Savery Electrical Services2021-12-24 | Arthur Fault? Bloody good bloke! Yip yip! Nah, I’m just pullin’ your Christmas cracker pal; this is a video about us *not* finding a fault. Well, we find half a circuit the fault isn’t on, but then Christmas comes along and we clock off. Should we survive the booze, food and Omicron variant, maybe we’ll post an update in the new year to show why this RCBO is tripping.
This one is less well explained, so I've thrown in some visual aids to show what we’re testing and what we’re seeing. Nonetheless, it may be a bit confusing as it’s us thinking on our feet out in the world where there’s not always a nice clear fault to easily be found.
The tripping RCBO has three circuits connected. The HomeServe chap who came before us has disconnected the circuit that has a low insulation resistance of 0.3MΩ, something we verify before we start dicking around. This is shown at the nine-minute mark.
We then restored power to the other circuits so we could see what was working and what was dead. The exterior lighting was not powered, so we started there.
At the fifteen-minute mark, we thought we’d traced the fault. An IR test on what we think are exterior bollard lights was at zero, so with those disconnected, we returned inside to test back at the board. To our dismay, the IR result was now even worse – a straight zero indicating a resistive short.
To prove a resistive short, the Metrel was switched to continuity mode at 15:47 and a test was performed between L+N and the earth bar. A reading of 1.08Ω was returned and, surprisingly, the live RCBO tripped off even though our circuit under test had been disconnected and was supposedly isolated from everything else. Naughty naughty: we should really have powered off the CU while dicking around dead testing.
The energised RCBO tripping on a continuity test for a circuit that's supposedly disconnected and isolated can only happen if our tester has found a common path to neutral i.e., if our faulty circuit’s neutral was cross connected to an energised neutral on another circuit, as that would provide a path that was resistively shorted between N-PE (they being connected together at the head).
At 16:55, I test for a neutral cross connect by continuity testing between the disconnected circuit neutral and the neutral bar. A reading of just 0.90Ω is returned where there should be no continuity between individual circuits. This explains why they shared an RCBO as splitting them would have caused tripping issues when the lights were turned on. It goes to show one shouldn't assume a disconnected circuit is always isolated, especially where it's evident a moron has been fiddling with the wiring.
AT 17:40, we figure the discrepancy between the IR figures obtained at nine minutes and fifteen minutes is because the first test was undertaken with the main switch off, so the tester recorded only the circuit earth fault which has a higher resistance and bombs out at 0.03MΩ, whereas the second test was performed with the other circuits energised, thus providing a path via a neutral cross connect, through the RCBO, through the main switch, through the connection between N & E at the head (which is a low resistance connection compared to the circuit fault), then back through the main earthing to the tester. The 1.08Ω recorded earlier was the resistance of this path.
Make sense? Crikey, try picturing it all in your head when it’s the last job before Christmas and you just want to get down the bloody boozer!
To show that the first IR reading was down to the fault and the second was down to the N-PE path through a cross-connect, that path is closed at 18:10 by knocking off the main switch and the test then repeated. The tester is forced to pass through the circuit fault again as that’s the only path now available, and this time we get a similar number to that of the nine-minute mark, 0.04MΩ.
Fault finding and correction is made much more difficult here because the electrical installation is gash and obviously the work of an amateur. I’ve said it before, but while an amateur may well get something working, that doesn’t mean it’s safe, has any longevity or that the likes of us won’t have to rip apart the walls and ceilings should it all go wrong.
The bonnie situation: The hall, kitchen, exterior lights and ventilation are back on. The cabling tests good going into the outside bulkhead, then reads bad going out. From here it goes on to serve the two bedrooms, so they’ve been left disconnected. Partial success to date then, although we still need to find why the bedrooms are borked and that’ll likely involve opening the ceilings.
Don't worry, Nigel will get over his hissy fit and be back for more abuse in 2022.
A previous video where he and I were trapped in a dank cellar with no lighting and had to rub each other off is… on OnlyFans…, but another one where we had to actually fix the lights can be found here: youtu.be/-BMMoqCQCYoToaster trip tip #shortsDavid Savery Electrical Services2021-12-17 | A quick vid on a common cause for CURRANT leakage in toasters; something that’ll have your RCD (GFCI) clicking off whilst browning your buns, toasting your teacakes or burning your bagels.
Yes, I know YouTube shorts are supposed to be under sixty seconds, but when did I ever play by Google’s stupid rules? Oh, and I also know there’s a tray on Dualit toasters for the removal of dropped debris, but one needs to give it a good clonking to get any soggy fruits from between the element and metalwork.
There’s no coffee shout-outs on short vids, but don’t RAISIN any complaints as more substantial content will be released over forthcoming DATES. Besides, y'know you wait for ages and then my videos get released in PEARS. Rest assured, the next one’s an absolute PEACH: take my word for it or suck my PLUMS you mother-FRUITERS.
Belated warning: Contains strong language. But hey, if it fixes your toaster, it can’t be the worst thing that happens to you today so simply hit ‘dislike’ and bugger off. Personally, I preferred it when YT showed the thumbs-down count, but then I’m not in control of this happy-clappy world. I’m just a prick who beats the fruit out of toasters while Nigel watches on with his hand down his trousers.
My homemade MFT PAT adaptor for testing troublesome toasters, tea-urns, TVs and... well, anything of a Class I bent that happens to have a plugtop: youtu.be/lyH0qhfyAosMuch ado about neutral tripperyDavid Savery Electrical Services2021-12-05 | Forsooth! A tale of handsome knight and his gnome-hatted gollum riding forth in ye ’olde Ford Transit carriage through fiery autumnal sunshine in Shakespeare’s County toward a perilous RCD trip & rescue of fair maiden from within tall keep of yon castle and... actually, let’s just fix that RCD.
Interesting as it perhaps is to see a backfeed of an RCD via what is presumably diverted neutral current from neighbouring properties. It looks like Jack and Jill Jones up the road have a problem or three with their electrical installation sending current down their earthing/bonding instead of their neutral. Still, it shouldn’t be noticeable to their neighbours Devinder and Deepali Doe; at least, not until they happen to have a neutral to earth fault of their own downstream from an RCD… in which case, they’re fu*ked.
For web hosting, get £10 off at Krystal with the code DSESELECTRIC at checkout! krystal.ukA Van Yack With THAT J. Beck.David Savery Electrical Services2021-11-27 | The charismatic James Beck joins me in the outside broadcast studio*, yet even his wit, wisdom, insight and suspiciously clean array of tools [insert raised eyebrow emoji] can’t save this video from being dragged into the doldrums by my lack of personality. PAH! What a gyp!
Yes folks, *THAT* James Beck of the JBE YouTube channel: our man in Manchester, Klein Tools bumder and notable Veto Pro Pac fag-hag has deigned to place his fine lightly-haired buttocks upon my Ford’s polyester seat cushions as we chew the fat, talk turkey and discuss topics so hot, you don’t even realise they even are topics anyone in the world ever gave a toss about!
So, sit back, pour a stiff drink, and sit through half an hour of van-waffle, then try and recall a single word that was actually said. I dare you. I bloody double dare you!
*Old Transit van with semen stains on the seats.
The first ten seconds have been edited out. Sorry if you missed it. That'll jolly well teach you to not tune in to my rubbish as soon as it's uploaded and before anyone can complain!
My thanks again to Max at MB Installations for the interesting things: mbinstallations.co.uk
For an honourable mention in the next dishonourable video, and to keep me and Nigel on the liquid lunches, you can buy us a beverage here: buymeacoffee.com/dseselectric
For web hosting, get £10 off at Krystal with the code DSESELECTRIC at checkout! krystal.ukThree-fault FridayDavid Savery Electrical Services2021-11-14 | Not as fun as sloppy-seconds Saturday but that’s another video entirely. Instead, we have Friday fault finding faff following friggin’ fitter’s fishy fittings flippin’ flooding!
Yes, I give you not one fault, not even two, but three (count ‘em!) and all at the same site! We were called after a duff drainpipe drenched the foyer and basement bathroom.
See pinned comment for erratum!
One: RCD fuse unit seized.
Two: An aged breaker more sensitive than a left-wing metrosexual carrying an iPad in a rainbow-coloured man-bag to deliver a diversity training course at the BBC.
Three: Bathroom lights that pop as you plonk your buttocks onto the windowless basement bog.
Energising known bad wiring isn't ideal, a point laboured in the ending, but it’s important to verify a fault condition before undertaking remedial work so you can confirm what’s reported is accurate and you know you’re making a difference when wielding the tools. Once verified, we get the tester onto it and pull out some numbers. Is there resistance to earth? Does it pass an IR test to earth? If it’s a line/neutral fault, what’s the resistance between those cores before we remove loads?
With the baseline data, we hopefully know what kind of fault we’re looking for and perhaps where to start looking. Here, the location was given away by an audible report in the bathroom. We'd been told it was the lights at fault as they had been seen wet, but the downlight holes merely provided an escape for the sound.
Usually a faulty circuit doesn’t give a clue as to quite where the failure is, so we figure out the likely halfway point, disconnect it and see which half the fault is on. Repeat until it’s cornered. Here, there were no points to break it down as all rooms had downlights caulked to the ceiling, their removal risking damage to finishes and, as we found, even extracting them didn’t guarantee access to any logical junction arrangement.
The JB we found in the bathroom served the fan and lights. The CPCs were presumably disconnected because the downlights were originally 12V MR16s. At some point the transformer(s) had been binned for a GU10 conversion leaving cabes & accessories on 230V. The faulty cable was tee'd off before that junction from somewhere we haven’t seen. It looks like that cable provided a non-fused non-isolated L-N-PE to the fan point, albeit disconnected and hiding in the wall. Maybe it had been there since the bathroom was fitted 20 years ago? It wasn’t visible until we wanged a hole in the fan liner, so it appeared the fan had just one cable going back to the JB. We had no way of knowing there was another cable there until the liner was opened.
We only had two ends of the circuit to work with – the CU reporting a fault downstream & the JB in the bathroom with a fault upstream. There were no other junctions to find without smashing out walls/ceilings. It was fortunate that visual and audible cues were present. Had that cable been obscured, we’d have nothing to go on.
This is a rare example of dead testing can only getting us so far as there wasn’t enough of the circuit accessible to work with.
The damage could have been worse: Four 20mm holes in the ceiling for the camera; the fourth hole betraying the location of a JB in the wall. A section of wall was cut for access. Finally, the fan liner had a chunk taken out of it and a hole was opened in the tiled wall for us to gain access.
One may argue we were wrong to re-energise even with the fault found, after all there are cables without CPCs, a live cable above the bath in a gel box, a JB still in the wall and non-fire rated downlights. Well, we’re not here to cure all the ills of others and we’ve only so much time booked to a job and limited permission from the client on what they'll put up with. Our brief is to find the fault & get the lights back on. That we did. We found a load of other cack requiring rewiring/repair/replacement, but all we can do is inform the client and urge them to book us, or any reputable spark, to put right. We can't force them to do so. Some may say it's better to leave the circuit disconnected, but the homeowner was pulling a floor lamp into the bathroom off a non-RCD socket so they didn’t have to bathe and crap in darkness. What’s safer, getting the lights on, even with their problems, or leaving the client with a trailing cable trip hazard, operating a Class I floor lamp potentially with wet hands? If we refused to restore lighting, they would have found someone else who could.
Is the place safer now than before we turned up? Yes. It is.
We advised the client of what's needed, but there are no more C1 conditions and it’s up to them whether they go to the effort and expense of paying heed.
The Metrel MI3152 is on loan in a deal where we get to play with something shiny we can’t afford, & Metrel get their wares shown to the five subscribers I have here on this channel. Then we hand it back to ‘em slightly worse for wear. Everyone’s a winner. Sort of.Amazeballs OZEV EV installation... #shortsDavid Savery Electrical Services2021-10-28 | Good to see that government grant, like with the PV industry, is going to competent installers who are diligent about their work on people's homes.
Yes, these lads must have been proud of their efforts as they went and slapped their label on the thing. A slow clap all round fellas.A proper builders breakfastDavid Savery Electrical Services2021-10-17 | A call out to the same place featured in our toilet tripping video from June and where we have a new fault to find, only now some new electrical work has gone in as part of an extension. Coincidence? Or could this dog’s dinner be a builder’s breakfast? Hmmm... I wonder…
Yes, we informed the homeowner we were getting this one on camera so that we couldn’t be accused of any untoward meddling by the builder who has energised new circuits installed with all the workmanship of a boiled potato. Here, I’ve listed some of the basic regulatory non-compliances as we’ve gone along so that you can play the fun game of looking them up for yourselves, but it should be noted that the regulations identified are not necessarily exhaustive, indeed if you believe I’ve missed out any that are relevant to the horrors evident herein, feel free to pipe up in the comments.
In my telephonic argument with the asshat who performed this work, he not only angrily stated he was an electrician (snort!) but that he “does loads of work for the Council!” Oddly enough, I’ve heard that before - like council work is supposed to be some kind of badge of honour or high accreditation. I’m not sure why anyone would think they’re the dogs-bollocks by being able to say “I do low-cost repairs to cack social housing and cash-strapped public buildings for a bunch of public sector layabouts in cheap Tesco suits who haven’t the first clue about whether the workmanship is competent or not!” Still, he was sporting such as a chufty badge for whatever he thought it was worth, yet on my impressed-o-meter which has a calibrated scale of “so-f*cking-what” all the way up to “allow-me-to-give-you-oral-sex-right-now”, his boasting scored a lowly “piss-off-you-clown” which, needless to say, is waaaay down at the bottom end.
If he can’t see what’s wrong with his work, then he’s ignorant at best. Unfortunately, he’ll likely kill someone else rather than himself as that generally seems to be the way the world works.
Anyway, you don’t need me to tell you this guy is a clueless liability, and you don’t need to hear any defence he may have for why he left this installation in the condition we found it in. The cold, hard facts are that numerous violations to BS7671 were evident in his work, and yet that hadn’t stopped him from energising it for a period of days. He’d left the installation in a more dangerous condition than before he started and he should never have made live any wiring that was not RCD protected, in contact with non-electrical services, had exposed basic insulation, lacked CPC continuity on live cabling, had opened live parts to exposure in the consumer unit and had an insulation resistance fault introduced through his own cack-handedness that left this family home tripping off whenever high current loads were in use.
As for twisting cores and ringing a three-outlet circuit in a tiny extension… well, back to school with you sonny as you obviously haven’t been to a training college of any kind anytime recently and, for goodness sake, take a peek inside BS7671 you complete dickhead.
One thing I would say is that we ourselves have ballsed-up here as what we should have done to limit our own liability was ascertain at the CU that the fault was on the new wiring, disconnected that new wiring, plugged the CU gaps and walked away leaving the original installer to perform the fautfinding and to accept the responsibility of re-energising their circuits.
Links:
Our previous video where we undertook unrelated RCD tripping at the same site in June: youtu.be/EL6RVAMUHmg
Affiliate links:
For a shout out on the next video, you can sport me and Nigel something warm, wet and brown here: buymeacoffee.com/dseselectric
For web hosting, get £10 off at Krystal with the code DSESELECTRIC at checkout! krystal.ukThe Manor House Refurbishment... 6David Savery Electrical Services2021-10-08 | ACTION AND EXCITEMENT… is in the thumbnail only and is otherwise sadly lacking in this, an exercise in how me and Trevor installed kitchen electrics with no flimmin’ measured plan and a client who moved the goalposts after first-fix.
We actually finished at the Manor House a year ago last week and this video was supposed to be edited last Christmas, but… meh. I got drunk and just couldn’t be bothered. We were back in May ’21 for some garden lighting shenanigans which got glued onto the end, so that’s a bonus for your having to wait a year to see how it all turned out… if indeed, you view additional footage of us as being a positive in any kind of way, shape or form.
Now we really are done there, at least until the kitchen is knocked down, but that may be a year or three away.
It’s another long ‘un. For every person who says my videos are too long, I get messages from people asking me to cut less out. Still, nobody ever said you had to watch it. In fact, I wouldn't bother if I were you. There’s a lot here of me and Hilary discussing her new kitchen layout which I was going to excise from the edit, but this is an example of the type of job we sometimes walk into: not everything has a measured plan and a client who knows exactly what they want, and this video shows how we go about getting the data we need to get on with throwing in the first-fix…
…which then all went to cock anyway as she ditched a 600mm kitchen unit in favour of one half the size leaving our accessories kinda out of place, although the fitter managed to work around them for a successful outcome.
Stupidity: At 10:32, Nigel foolishly handles live equipment without observing safe isolation. Rest assured; he was reprimanded off camera and cried for ages about his smacked bottom which is why the scene was cut at this point. There are also scenes where Nige uses an SDS chisel and a multitool without goggles or ear defenders. You can’t teach an old dog new tricks… or a stubborn Brexit voter common sense. Kids; don’t do what dickhead Nige does. Do do what David deems demonstrably doable and don defensive duds when doing dangerous duties.
Links: Andrian Davey has an informative video on wall chasing and prescribed zones here: youtube.com/watch?v=5BowwIIbgGU&t=1285s Adrian wouldn’t like the way we’ve run some of these chases and, technically, he’s not wrong. There is however a balance between the ideal and what you’re faced with out on site.
We make reference to another video where Nige shows off a stool and pencil. Yes, it’s a roller coaster ride and you can view it here: youtu.be/ZQrtJ2IBWRU
The montage tuneage is from a game called Astro Tripper (2008) on the PS3. If you got onto the high score table, this is the ditty that played as you entered your name. Liking it as I did, I hooked up my console to an audio capture device and snaffled the thing as an MP3 about ten-years ago. I emailed the publisher, PomPom Games, back in 2019 to ask if I could use it on a video, but I received no response. I think they ceased operations in 2015 and today their website no longer exists at all. I hope whomever composed it doesn’t mind my using it here.
For web hosting, get £10 off at Krystal with the code DSESELECTRIC at checkout! krystal.ukTwo dicks, one hole... and a new C.U.David Savery Electrical Services2021-10-02 | Two idiots spend half a video figuring out how to drill a tricky hole into a flimmin’ wall before (not really) showing how we replaced a consumer unit for a new Scolmore Click Elucian model. Yes, originally filmed in June, it was only afterwards I realised we had a video of us boshing a hole through a wall and not much else. Never mind, I was back on site recently once Western Power had done their thang and I managed to capture a little more on camera... for what it’s worth.
As usual, my apologies for some auditory annoyances; it seems my van-cam has decided to apply a farting noise to its audio. I’ve run it through a cleaner, but it may be patchy in places.
This isn’t a sponsored video and Scolmore didn’t pay us to show off their wares. I bet Bundy got paid to blow smoke up their arse, the Rhino Insurance discount code butt-sniffer.
Like the SBS board I put in with Linda, it’s not my neatest work. In fact, maybe I should stop undertaking CU moves/replacements as I’m clearly no good at the artistry of it and I hate doing 'em anyway.
For a shout out on the next video and to keep me and Nigel twitching with caffeine, you can buy us a mug o' watery brown grit here: buymeacoffee.com/dseselectric
For web hosting, get £10 off at Krystal with the code DSESELECTRIC at checkout! krystal.ukIts the first Elex since... well.. the last Elex. And it was a bit cack with some big names missingDavid Savery Electrical Services2021-09-20 | Yes, it's Elex, the electrician's trade show, the first one since things got locked down last year and a much scaled down affair compared to normal. Nige and I attended along with Linda who has been working with us of late and has never attended an Elex show before.
As mentioned, I also talked in an eFixx video about the show here: youtu.be/luPMlC_PzDg
For web hosting, get £10 off at Krystal with the code DSESELECTRIC at checkout. krystal.ukDead testing with Amy the SparkDavid Savery Electrical Services2021-09-02 | A whole hour of dead testing and form filling in part two of our three-part series. Yes, it is as exciting as it sounds. This follows our unboxing video. Before you comment though, a ranty disclaimer if you will:
It’s important to recognise this video for what it is, and what it is is simply two house-bashers shooting the breeze familiarising themselves with the TIS MFT-Eco tester while undertaking the everyday tests used out in the world.
What this video is not:
A classroom teaching aid. A definitive testing guide. Guaranteed correct, complete and error-free. Devoid of gutter utterances. A way to improve your sexual prowess.
Yes, it’s long, it’s boring and it contains colourful language, but that’s because it’s informal – it was just Amy and me on the day recording our procedures, thoughts and observations off-script while we rattled through testing as the camera rolled and with a really crappy microphone setup that'll set your teeth on edge. Anyone expecting more or different is advised to look at the Sparky Ninja, e5, John Ward and eFixx channels, among others, for better informed and classroom-friendlier content.
For those who say “I wanted my son/daughter to see this video but you ruined it with your bad language”, rest assured that if your son/daughter is old enough to understand electrical testing then they’ve probably already forgotten more rude words than you’ll ever know. If your son/daughter is getting into the trades, they won’t last long if salty speech sends them sobbing to their safe space. If the presentation of this video isn’t for you, then it isn’t for you. Nobody ever guaranteed otherwise.
I’m sorry to sound so defensive, but you literally can’t put anything on the likes of YouTube without someone moaning about it not meeting their specific expectations like I was supposed to have them personally in mind while making it. Videos like this really attract the whining pricks too as they want the information but are never happy about how it’s handed over. Here’s an idea for anyone who doesn’t like it: go read the books and do your own research; you don't need us to lay it on a plate for you.
Chapters: 0:00 Fault demonstration 4:30 Appliance IR test 7:03 Mega vs. Meg 09:08 Proving dead 11:17 Tedious sweary IET model form rant as already covered in previous videos 15:11 Lead nulling 15:46 Ring socket r1, rn, r2 23:15 Ring socket R1+R2 31:05 Ring socket R1+RN 31:45 Ring socket Insulation Resistance 38:55 Radial socket R1+R2 40:33 Radial socket RN+R2 43:25 Radial socket Insulation Resistance 48:56 Lighting radial R1+R2 53:06 Lighting radial Insulation Resistance 53:56 Fault found! 55:58 Earth leakage
If this rubbish has been of some help, feel free to donate something warm and wet for our trouble and you'll be name dropped in a future vid (although not the next one as that's already edited). buymeacoffee.com/dseselectric
For web hosting, get £10 off at Krystal with the code DSESELECTRIC at checkout! krystal.uk
This is not sponsored content.MFT-Eco unboxing and mansplaining with AmyDavid Savery Electrical Services2021-09-01 | Amy the Spark (34) came to visit me in August for a little play on my ol’ test rig and we figured if we were going to prat about doing that, we may as well do it with the TIS MFT Eco, the new lower cost sister model to my MFT Pro. In the end, we were at it for so damn long, we ended up with hours of footage that I’ve had to split over three videos and poor Amy barely gets a word in edgeways in any of them!
If this has been some help, feel free to donate a coffee to the cause and you’ll get a shoutout in a future video (although not the next two with Amy as they're already edited and uploaded!): buymeacoffee.com/dseselectric
For web hosting, get £10 off at Krystal with the code DSESELECTRIC at checkout! krystal.uk
This is not sponsored content.Dual busbar drunkenness with LindaDavid Savery Electrical Services2021-08-30 | Who? Yeah, Linda - a worse alcoholic than me which means when she's out on the van, the van's generally parked outside the pub. That can't be good, but before we get there, let's slap another of those rather spiffing SBS dual busbar babies onto somebody's garage wall.
We were supposed to do more work here but Nige went on holiday and came back with some kind of yeast infection or something. A pimply rash all round the back of his barse and up between the dirty pillows by all accounts. With him off sick, we were only able to do half a job but, well, some would say that's par for the course even when Nige can be bothered to clock in.
Filming on-the-job's a bit chaotic and random but I'm not about to buy a £400 HD camera and pay some biffin to follow me around, so it is what it is and it'll jolly well stay that way. You're in the wrong place if you expect slick production values - maybe go watch one of those other fruits pretending to like Tradify. BTW, they offered to pay me too, but I tried their wares and I prefer YourTradeBase which I've paid to use since 2016. There's a referral link below.
And no, even this isn't a sponsored video - SBS don't pay me to say nice things about them, I just like their bling.
Finally, no chauvinistic comments about my having some skirt on the van if you please. Linda's a mate and I won't take kindly to anyone getting out of order. Let's keep the bants friendly my friends!
Affiliate links:
If cack like this is your cup of tea, you can buy us a coffee and get an honourable mention in a future video. Not one of the next three coming out this week though as they've already been edited and uploaded! buymeacoffee.com/dseselectric
For web hosting, get £10 off at Krystal with the code DSESELECTRIC at checkout! krystal.ukGoofing off to buff my P.V. stuff!David Savery Electrical Services2021-07-25 | I wish my wife was as dirty as my solar panels! Ho ho; SNORT! But seriously folks, cleaning solar panels is no laughing matter as this forty minutes of tedium proves. Here, we use a DIY tower platform to undertake the DIY task of cleaning my array on the DIY disaster that is my own home. If one were to offer such a task commercially, a PASMA approved platform and qualifications would likely be needed.
Perhaps view this then not as a how-to, but as a how-I-happened-to. Grubby panels means a drop in yield and a reduction in the free juice you can make on a bright day as well as a shortfall in returns for any feed-in tariff or exported electricity.
Warning: contains one of Nigel’s rambling mental breakdowns, this time about Izal toilet paper found in many a British state institution at around the same time as Jimmy Saville was trying to convince us all to wear a seatbelt. My apologies.
The music on this one comes from the @JamHamster channel and contains scenes of once popular nonces (not William Wollard who had some sage advice on what to do if your clothes caught fire). I hope I’m okay using these ditties – I approached JamHamster twice on Twitter but was treated to the radio silence I probably deserve. JH – if you’re reading this, I’m happy to split the peanuts this rubbish makes in YT advertising! DM me!
JamHamster (Bod Remix – Bod ‘Avin’ it large!) (Clunk-Click The Hardcore Public Information Remix) youtube.com/user/jamhamster God, I miss those public information films. JIMMMMMYYYYYY
For web hosting, get £10 off at Krystal with the code DSESELECTRIC at checkout! krystal.uk(Drunken) Doomed lamp rantDavid Savery Electrical Services2021-07-14 | Oh dear. This was recorded last weekend after a few too many fruit juices. It’s a follow-up to our previous video where Nigel and I discussed the upcoming demise of certain lamp technologies under UK and EU legislation. Firstly, thank you to those who contributed to the comments that I included and expanded upon here. I’m sorry for the text to speech on some of them – maybe I should fork out for premium voices, but the cheap store-band whiskey I’m bashing through doesn’t pay for itself. I’m sorry I couldn’t include all comments; if you’re not mentioned in this one then it isn’t down to your opinion being in any way invalid, merely that I could hardly slur a sentence together toward the end and had to call it a night.
Secondly, I name drop a few marques who have let me down in this one. That’s not to suggest their wares are inferior, that they’re deliberately out to dupe the public with cost-cutting designs or that problems with one range is endemic of all their lines. What I talk about here is fact: hard indisputable fact. I’ve sold my clients certain products from named brands and those products have gone on to fail after just months and long before the claims made on the packaging at the point of sale. Not just on one site and not just from one batch. I’m talking about many examples over a period of time.
Because I made promises to my customer that moving to LED would save on maintenance, and because I’m the last link in the supply chain, the warranty becomes my responsibility and I’m having to change out failed LED technology at my own expense both on time to source a replacement, return to site and change out the failure, but also because if it’s been in stock with me for a while, I may no longer have a right to return it to my own wholesaler leaving me ponying up for new hardware and stuck collecting the faulty old stuff.
This is unacceptable. The whole point of this “cleaner, greener” technology is to reduce waste, not to add to the eWaste headache by throwing away LED lamps and luminaires where one tiny element pops rendering the whole bally thing unusable. The brands named herein are the ones I get called to time and again. I can prove that: I’ve got piles of their failures sitting right here. It’s all very well for their suits to suggest their gear is robust as, no doubt, they would, but that means nothing when I’m the one up a ladder pulling a dead LED fitting of theirs down after fewer than eighteen months of light domestic use.
For web hosting, get £10 off at Krystal with the code DSESELECTRIC at checkout! krystal.ukSH!T CHAT: Last orders on old lampsDavid Savery Electrical Services2021-06-30 | A look at lighting that’s destined to disappear from shop shelves near you in the near future. My glamorous (and somewhat harassed) assistant and I present the technologies new UK and EU legislation will soon consign to nought but memory.
Yes, even today’s young apprentices will eventually be able to say “you bloody kids nowadays with your LEDs! I remember when you could get lamps you could warm your hands over and others that weren’t at their operating output immediately at switch-on…. Harrumph!” before unwrapping a Werther’s Original to suck on while your dentures sit in a glass beside you. Of course, your grandkids won’t care; they’ll think you’re just an old bore who’s behind the times because you never upgraded from the Playstation 8, you still think that old crooner Ed Sheeran sounds ‘cool’ as he sings to grannies on cruise ships and your house smells like musty farts.
For a shout out on the next video and to keep me and Nigel from having to lurk in back alleys dispensing hand-shandies for coffee: buymeacoffee.com/dseselectric
For web hosting, get £10 off at Krystal with the code DSESELECTRIC at checkout! krystal.ukThe Manor House refurbishment... 5David Savery Electrical Services2021-06-20 | Sorry for the delay on this one; it was all filmed a year ago and I intended to run it through the editor last Christmas, but… well… better late than never. Although maybe not as there’s a lot of irrelevant talk and not much action in this one as we get power and comms over the eighty metres between the house and outbuilding.
There’s one more instalment now being worked on – the remodelling of the annex wing. Hopefully, I’ll have that up soon as there shouldn’t be a shed load of visual aids to prepare for that one!
The outbuilding is outfitted with an MCG consumer unit with a 100mA RCD main switch for fault protection and three 30mA RCBOs for store area lighting (6A), store area power (20A) and office area power (20A). A 35mm supply cable is probably total overkill for the loads in use over there, but it gives them plenty of wiggle room should they want to start fitting EV chargers, hot tubs or whatever else in the future.
Guidance Note 6: Protection against overcurrent. A right royal read if you can make sense of the IET’s typing errors and inability to structure a sentence in plain English. amzn.to/3zHJZF9
For web hosting, get £10 off at Krystal with the code DSESELECTRIC at checkout! krystal.ukTracing troublesome toilet tripping!David Savery Electrical Services2021-06-15 | A new one on us, even after all these years. Flush the loo to sluice out your poo and your RCD trips too! Headphone warning – my TIS MFT Pro was pretty close to the mic from the 7:54 mark which makes for some ear-fingering bleeps as it does its thang. Sorry.
Long story short, we didn’t find the point where the water was getting into the wiring although we were able to at least get it out of the way. We’ll leave the plumber to pull the kitchen apart in order to effect repair at which point we’ll have better access to nail the fault position.
And yes, we smelled somewhat eau de toilette after this one. Who said electrical work was glamourous?
This is where IR testing really comes into its own, although continued application can dry out your wet wiring making it appear the fault has gone away.
Don’t worry, the McHat hasn’t retired, it just has a few days off of late to save wear & tear!
Time on site: one hour. But we still needed a coffee afterwards.
For a shout out on the next video and to keep me and Nigel fully focussed, you can buy us a hand-job outside the back of Lidl here: buymeacoffee.com/dseselectric
For web hosting, get £10 off at Krystal with the code DSESELECTRIC at checkout! krystal.ukSBS Dual Busbar Consumer UnitDavid Savery Electrical Services2021-06-05 | Here, we peer at a rather nifty dual busbar CU design with additional bonus chat from Nigel about cakes. Apart from the bad language, what’s not to like?
SBS can be found at sbstradesales.co.uk and this isn’t a paid promotion. Pros? Cons? General thoughts? Anyone else out there plumbed in this kit over the years? Let me know in the comments, but keep them constructive people!
For a shout out on the next video and to keep me and Nigel fully fuelled, you can buy us a Twinky here: buymeacoffee.com/dseselectric
For alternative viewing options away from YouTube, see www.dses.tv
I was in error stating that Wylex devices no longer support their balcony busbar consumer units. While their NHXL devices aren't compatible, their NHX models are and those are still widely available. Why they need two models that are largely identical save for one having compatibility and the other not is another question entirely.
For web hosting, get £10 off at Krystal with the code DSESELECTRIC at checkout! krystal.ukNTT (NSFW): The Klein NCV Detector/Laser MeasureDavid Savery Electrical Services2021-05-11 | Oh, those poor folks in Klein’s marketing department. They’ll be all abuzz to hear someone is saying something nice about one of their products on social media only to then find this age-restricted horror show they can never refer anyone to. A few points if I may:
I’ve been inundated of late with people berating me for using bad language. Well, that’s how my channel rolls and this video aims to set a new low standard to ensure we’re all firmly on the same page about it. Seems there are electrical channels opening up every week by polite people who care about their marketing and professional presentation, who want to chase the subs numbers and who want free stuff from manufacturers, so, if that’s your bag, then there’s no need to be huffing and puffing about my output being different. It’s supposed to be different and I never made anybody a personal promise they’d like it.
I’ve finally kicked Movavi Video Suite out of bed as it’s caused me no end of technical trouble and their support is hopeless. In fact, they even pulled their own support email address, so when you open a ticket on their website to report a fault, you have no way of replying to their follow-up questions! I literally had to open a ticket to ask how I could reply to their responses on their tickets – for which they said they’d find out and get back to me and then never did! Truly, they are the Fawlty Towers of video editing software. Anyway, the dreadfulness you see here was authored using Cyberlink PowerDirector. A bit of a learning curve to get used to the new interface but Movavi not working properly was one of the reasons uploads have been quieter in 2021.
I’m now on Buy Me A Coffee as I’ve had messages from people in the past who kindly want to send a tipple my way but didn’t know how to do it. For those who contribute, I’ll shoutout in the following vid – and cheers! Alternatively, instead of wasting cash on me, maybe make a donation to the charity of your choice.
There’s no disrespect to Jordan at Artisan Electrics here. In reality, he gives me about as much wood as Nick Bundy can. I must admit though, I liked him better when he had half the subs I do.
For web hosting, get paltry £10 off at Krystal with the code DSESELECTRIC at checkout! krystal.uk(Arguably pants) Eco domestic lightingDavid Savery Electrical Services2021-03-29 | You know that old adage of giving the people what they want? Well, what you want is buried in here somewhere, but there's an awful lot of nonsense before you'll get to it.
Eco lighting is great, but well-meaning examples for the home from about ten to fifteen years ago were themselves outpaced by new technology. Join me on a trip down memory lane as I waffle on about lighting technology for far too long. Oh, and it’s even got Buck Rogers in it showing us his smooooth moves - and without a shred of irony too! Although, because of Buck’s presence, this video is blocked from viewing in the USA and demonetised. Cheers Fatso! Still, that’s YouTube. For what it’s worth, Stateside viewers can catch the fun on my LBRY channel or count themselves lucky they're missing out: lbry.tv/@dseselectric:e?page=1
I mention this tragic event because I've heard people say in the past that these two firefighters lost their lives as a result of collapsing cables like it was a lack of forethought or even negligence on behalf of previous electrical contractors to have used plastic trunking. It's not as black-and-white as that. Have a read of the report.
The copyright for any clips are the property of their respective owners, yada yada, etc. Did I mention I'm not getting any money for making this one? How about buying me a coffee if this content has been of use to you: buymeacoffee.com/dseselectric
What's that officer? The thumbnail? It's just from an image search of green leaves. Why, what's wrong with it?
For web hosting, get £10 off at Krystal with the code DSESELECTRIC at checkout! krystal.ukAbsolute sodden bollards.David Savery Electrical Services2021-03-14 | It is bloody bollards an' all. This is one of those jobs that took longer than expected and yet I couldn't tell you why. It just... well... kept us busy all day, interrupted as we were by rain, hail and an unseasonable bout of hayfever.
Indeed, we were so thoroughly wet, snotty, muddy and miserable by the end of it, I neglected to even get decent footage of some of the changes we made such as the LED driver installed in the isolator enclosure and the torpedo or 'submarine' joint Nige used to extend the SWA. Sorry. Still, if you want to see one of those up close and personal, there's an older video showing the installation of such on another SELV garden lighting job here: youtu.be/xNG6SFiMwAI
Don't worry, the McHat hasn't retired, nor am I sponsored by Klein Tools. I just like their hat and we share the same corporate colour scheme.