Uploaded February 2026 | Updated September 2026, 6 hours ago
The factory circuit drawing shows the chest lamp being ON whenever the power switch is ON, but most Radicon robots that I have seen only turn ON the chest lamp when the robot has received a signal and is running the mechanical sequencer. But the radicon robot I am taking apart right now is wired just like the factory circuit drawing, the chest lamp would be ON all the time the power switch is set to ON position. And there is a old video on YouTube from Ozzie with a Radicon robot where the chest lamp is ON all the time. Did someone repair his robot at some point and just follow the factory circuit drawing that might have been in error, or did they produce the robot for a short time where the chest lamp was in fact wired to be ON all the time.
Here is a link to Ozzies old radicon video.
youtu.be/nVTb3oEAHFg?si=Mhdv6elJe98OPX5H
Inside a distressed Radicon Robot video.
youtu.be/7dDC0kAi4v8?si=GFEPw8U7p0LaoCqi
Lets remove the head and arms of the Radicon robot.
youtu.be/q9qHN25NqQQ
Everything you wanted to know about the Radicon Robot.
youtu.be/zprnuCw5Kck?si=yRsiob0Rna4RY5jE
Make a coherer detector device.
youtu.be/2goZcVGqx4k?si=bOSjadSv9Vu3HgZH
Build a Piezo transmitter for your Coherer detector.
youtu.be/vZEtZ4koq_c?si=TO6bHFOcd7AWGrYy
3d printed Radicon Robot using a coherer detector and sequencer.
youtu.be/ffpTWWCSyO8?si=Sr0nnzk6lhIBocvc
Make a super sensitive meter relay for your coherer detector.
youtu.be/QuOplxj6HUc?si=_FSOQkK7ZP_YiClB
Hit the LIKE button so I know you care.
SUB for more vintage and custom robot fun.
Explore the Robothut channel for over 1700 videos.
The factory circuit drawing shows the chest lamp being ON whenever the power switch is ON, but most Radicon robots that I have seen only turn ON the chest lamp when the robot has received a signal and is running the mechanical sequencer. But the radicon robot I am taking apart right now is wired just like the factory circuit drawing, the chest lamp would be ON all the time the power switch is set to ON position. And there is a old video on YouTube from Ozzie with a Radicon robot where the chest lamp is ON all the time. Did someone repair his robot at some point and just follow the factory circuit drawing that might have been in error, or did they produce the robot for a short time where the chest lamp was in fact wired to be ON all the time.
Here is a link to Ozzies old radicon video.
youtu.be/nVTb3oEAHFg?si=Mhdv6elJe98OPX5H
Inside a distressed Radicon Robot video.
youtu.be/7dDC0kAi4v8?si=GFEPw8U7p0LaoCqi
Lets remove the head and arms of the Radicon robot.
youtu.be/q9qHN25NqQQ
Everything you wanted to know about the Radicon Robot.
youtu.be/zprnuCw5Kck?si=yRsiob0Rna4RY5jE
Make a coherer detector device.
youtu.be/2goZcVGqx4k?si=bOSjadSv9Vu3HgZH
Build a Piezo transmitter for your Coherer detector.
youtu.be/vZEtZ4koq_c?si=TO6bHFOcd7AWGrYy
3d printed Radicon Robot using a coherer detector and sequencer.
youtu.be/ffpTWWCSyO8?si=Sr0nnzk6lhIBocvc
Make a super sensitive meter relay for your coherer detector.
youtu.be/QuOplxj6HUc?si=_FSOQkK7ZP_YiClB
Hit the LIKE button so I know you care.
SUB for more vintage and custom robot fun.
Explore the Robothut channel for over 1700 videos.










