Why calibrate at all? And what's with the eCal?
Sign up for Wave! ► bit.ly/JoinWave2018
Subscribe ► bit.ly/KLabs_sub
Applying Error Correction to Vector Network Analyzer Measurements App Note:
wavekeysight.com/making-rf-magic/#NetworkAnalysis
Wave 2018 FAQs:
keysight.com/main/editorial.jspx?cc=US&lc=eng&ckey=2939162&id=2939162
Bench Bundle:
MSOX3054T Oscilloscope, 500MHz
DSOXT3APPBNDL application bundle license
33622A Waveform generator, 120 MHz, 2-channel
34470A Digital multimeter 7 1/2 digit Truevolt DMM
E36313A DC power supply, triple-output 160 W
U1281A True RMS 60000 Count Handheld DMM
RF Bundle:
N9918A 26.5 GHz FieldFox Microwave Analyzer
N9918A-211 Vector network analyzer full 2-port S-parameters
N9918A-233 Spectrum analyzer
N7555A ECal Module DC to 26.5 GHz, 2-port
Today we look at network analyzer calibration.
We all know you have to do it, but it takes time. What if you could do precision calibration much faster?
We all learned about network analyzer calibration in college—probably using a mechanical calibration kit like this one.
Mechanical calibration kits typically contain individual standards to characterize systematic errors—open, load, short and thru. These are connected and disconnected in a specific sequence to calibrate the test set up and remove errors.
A full 2-Port calibration process requires six connections — three standards at each test port. The second step is the THRU where the two test ports are connected to each other. All of this requires a lot of connecting and disconnecting!
Today, there is an alternative to traditional mechanical cal. It’s called electronic calibration—or Ecal.
An Ecal module is a solid-state calibration module which makes two-port calibration fast, easy, and less prone to operator errors. It has a simple set up and you get excellent accuracy without spending a bunch of time to calibrate.
#ecal #VNA #vectornetworkanalyzer #networkanalyzer #2PortCal #Calibration #VNAcal #Wave #Keysight #Wave2018 #WaveWinners
Why calibrate at all? And what's with the eCal?
Sign up for Wave! ► bit.ly/JoinWave2018
Subscribe ► bit.ly/KLabs_sub
Applying Error Correction to Vector Network Analyzer Measurements App Note:
wavekeysight.com/making-rf-magic/#NetworkAnalysis
Wave 2018 FAQs:
keysight.com/main/editorial.jspx?cc=US&lc=eng&ckey=2939162&id=2939162
Bench Bundle:
MSOX3054T Oscilloscope, 500MHz
DSOXT3APPBNDL application bundle license
33622A Waveform generator, 120 MHz, 2-channel
34470A Digital multimeter 7 1/2 digit Truevolt DMM
E36313A DC power supply, triple-output 160 W
U1281A True RMS 60000 Count Handheld DMM
RF Bundle:
N9918A 26.5 GHz FieldFox Microwave Analyzer
N9918A-211 Vector network analyzer full 2-port S-parameters
N9918A-233 Spectrum analyzer
N7555A ECal Module DC to 26.5 GHz, 2-port
Today we look at network analyzer calibration.
We all know you have to do it, but it takes time. What if you could do precision calibration much faster?
We all learned about network analyzer calibration in college—probably using a mechanical calibration kit like this one.
Mechanical calibration kits typically contain individual standards to characterize systematic errors—open, load, short and thru. These are connected and disconnected in a specific sequence to calibrate the test set up and remove errors.
A full 2-Port calibration process requires six connections — three standards at each test port. The second step is the THRU where the two test ports are connected to each other. All of this requires a lot of connecting and disconnecting!
Today, there is an alternative to traditional mechanical cal. It’s called electronic calibration—or Ecal.
An Ecal module is a solid-state calibration module which makes two-port calibration fast, easy, and less prone to operator errors. It has a simple set up and you get excellent accuracy without spending a bunch of time to calibrate.
#ecal #VNA #vectornetworkanalyzer #networkanalyzer #2PortCal #Calibration #VNAcal #Wave #Keysight #Wave2018 #WaveWinners