Most homes have no mechanical ventilation. As envelopes tighten for energy performance, the natural air exchange those homes relied on disappears, and carbon dioxide, volatile organic compounds, PM2.5, and moisture accumulate indoors. Bedrooms are the worst case, routinely climbing from an outdoor baseline near 420 ppm CO2 to between 1,500 and 2,500 ppm overnight with the door and windows closed.

Building codes and standards including ASHRAE 62.2 now treat mechanical ventilation as a requirement, yet only a small fraction of existing homes have any dedicated fresh air system. The barrier is not the technology. Ducted heat and energy recovery ventilators have been well understood for decades. The barrier is cost, invasiveness, and the fact that renters and multifamily occupants cannot modify walls at all.

This session covers what actually happens to indoor air in a tight home, how to interpret real CO2 and VOC data from occupied bedrooms, why portable filtration does not address gaseous contaminants or air exchange, and how to evaluate ventilation strategies for homes where ductwork is not an option. Attendees will review anonymized before and after monitoring data from field deployments across cold, hot humid, and wildfire affected climates, and will leave with a practical framework for matching a ventilation approach to a specific building, occupant, and climate.

Prerequisite knowledge: none required. A basic familiarity with residential HVAC concepts and the difference between filtration and ventilation is helpful but not necessary.


Submitted for 1 (One) Hour Continuing Education Units (CEUS) in

• Green Business Certification Inc. (GBCI) - General
• LEED Accredited Professional HOMES (APH)
• American Institute of Architects - AIA (HSW)**
• Building Performance Institute (BPI) - All Credentials
• GHI Certified GreenHome Professional (CGHP) Pillar(s): Energy, Health
• American Institute of Building Designers (AIBD)
• Building Science Institute (BSI) Verifier
• Society of American Registered Architects (SARA)
**State Architect / Builder License may be applicable


Need CEUS?
Take the Quiz here:
greenhomeinstitute.thinkific.com/courses/ventilation-without-renovation-solving-high-co2-poor-air-exchange-in-existing-homes


Speaker

Austin Riesenberger is the founder and CEO of SWERV Inc., a Boston based hardware company working on residential ventilation, based at Greentown Labs in Somerville, Massachusetts. He holds a degree in physics from St. Lawrence University and a degree in mechanical engineering from Columbia University through their 3+2 engineering partnership.

Austin came to indoor air quality personally. He was diagnosed with asthma and spent most of his life sleeping with a window open in every season because it was the only thing that reliably let him wake up with a clear chest. He later worked in commercial HVAC engineering, including at Arup in Boston, where he designed and commissioned ventilation systems for schools, hospitals, and offices, and realized that the same energy recovery ventilation code required in a classroom is almost entirely absent from the bedrooms where people sleep eight hours a night.

Over the past two years he has built hundreds of window ERVs and custom test rigs, and has run hundreds instrumented field deployments across the US in early customer's homes. He has appeared on the Building HVAC Science Podcast and Less Talk More Action, and speaks regularly on residential ventilation, the retrofit gap, and what real occupied-home monitoring data actually shows.


Lessons Learned

1. Understand that inadequate mechanical ventilation in homes can lead to elevated levels of carbon dioxide and volatile organic compounds, significantly impacting occupants' health over time and how it assocates LEED Residential V4.1 EQ Prerequsite Ventilation
2. Analyze the safety risks associated with high indoor pollutant concentrations, recognizing that chronic exposure can lead to serious respiratory and other safety concerns.
3. Introduce effective ventilation strategies tailored to specific building characteristics, ensuring that welfare considerations, such as occupant comfort and air quality, are prioritized in residential settings and how it achieves LEED BD+C V4 HOMES EQ Credit Enhanced Ventilation
4. Articulate the differences between various ventilation systems, emphasizing their unique impacts on health, safety, and welfare outcomes to help occupants make informed decisions and how it helps with LEED Residential V4.1 EQ Credit Enhanced Ventilation
Ventilation Without Renovation: Solving High CO2 and Poor Air Exchange in Existing HomesAll about solid cellulose batt insulation that is DIY friendlyHow to Become a LEED Green RaterClosed Loop Communication For Better High Performance HomesEarth Week Fundraiser - What are the benefits of our CEU webinars?Elevating Wellbeing Through Biophilic Design: Creating Nurturing EnvironmentsMINetZero Tour Trailer | Passive House | LEED | DecarbAbout ADU: The Perfect Housing SolutionLittle Residence Green Home & Solar TourThe Future Is Panelized: Building Better with Precision, Performance and Efficiency in MindManual J Load Calculation: Intro to sizing heating and cooling systemsHemp Insulation 101
GreenHome Institute |

Ventilation Without Renovation: Solving High CO2 and Poor Air Exchange in Existing Homes

SHARE TO X SHARE TO REDDIT SHARE TO FACEBOOK WALLPAPER