Uploaded February 2026 | Updated November 2026, 2 hours ago
Logic analyzers allow you to trigger when the signal is high, low, has a rising edge, has a falling edge, or has any type of edge. These triggers work well for identifying button presses (rising or falling edge) or the start of a communications transmission, such as the falling edge of a new UART byte or the falling edge of a /CS signal, etc. The setting to turn these on is usually near the signal itself. Many logic analyzers will allow you to set triggers on multiple signal lines, and, in most cases, these are OR-ed together, meaning that the logic analyzer will trigger if any of the signal lines are triggered.
More advanced logic analyzers can even trigger on pulse lengths or specific parts of a UART, I2C, or SPI transmission. The settings for these are not often situated near the signals themselves, but near the global trigger settings for the logic analyzer. The ability to match much more complex signal patterns means you can use these to find highly specific parts of your signals. For instance, you could use these triggers to locate not just the start of every SPI transmission, but just the ones that write to register 0xFF.
Triggers are critical for getting the most use from your logic analyzer and for finding the portions of your signals that you care about most.
Logic analyzers allow you to trigger when the signal is high, low, has a rising edge, has a falling edge, or has any type of edge. These triggers work well for identifying button presses (rising or falling edge) or the start of a communications transmission, such as the falling edge of a new UART byte or the falling edge of a /CS signal, etc. The setting to turn these on is usually near the signal itself. Many logic analyzers will allow you to set triggers on multiple signal lines, and, in most cases, these are OR-ed together, meaning that the logic analyzer will trigger if any of the signal lines are triggered.
More advanced logic analyzers can even trigger on pulse lengths or specific parts of a UART, I2C, or SPI transmission. The settings for these are not often situated near the signals themselves, but near the global trigger settings for the logic analyzer. The ability to match much more complex signal patterns means you can use these to find highly specific parts of your signals. For instance, you could use these triggers to locate not just the start of every SPI transmission, but just the ones that write to register 0xFF.
Triggers are critical for getting the most use from your logic analyzer and for finding the portions of your signals that you care about most.