Learn how to troubleshoot and test the compressor on your FCR16DCASA Furrion refrigerator in this step-by-step guide. If your RV fridge has power but the compressor is not running, this video walks through several simple checks that can help identify the problem.
Start by checking if the refrigerator is in lockout mode. In this situation, the lights may still turn on, but the compressor will not operate. The first step is performing a hard reset by disconnecting all power sources to the refrigerator, including shore power, solar input, and generators. Leave the unit without power for 5–10 minutes before reconnecting.
If the issue continues after the reset, the next step is to measure the amperage draw at the compressor. This reading can help determine what may be happening inside the system:
• 0 amps may indicate no power reaching the refrigerator, possibly due to a blown fuse or wiring issue.
• 0.5–2.5 amps may suggest low refrigerant levels.
• 3–14 amps is the normal operating range for the compressor.
• 15 amps or higher could indicate the compressor motor is locked up and the refrigerator may need replacement.
The video also explains how to test the compressor using the compressor control module. By placing a jumper wire between the C and T terminals, you can bypass the thermostat signal and attempt to start the compressor directly.
These troubleshooting steps can help you better understand what is happening with your RV fridge and determine the next steps for repair or replacement.
Watch the full video for a detailed walkthrough of testing the compressor on the FCR16DCASA Furrion refrigerator.
Shop our store at lippert.com/rv-camping/appliances/refrigerators
For technical resources and support, visit support.lci1.com/, and don’t forget to subscribe to our channel!
#lippert #furrion #rvfridge #rving
Learn how to troubleshoot and test the compressor on your FCR16DCASA Furrion refrigerator in this step-by-step guide. If your RV fridge has power but the compressor is not running, this video walks through several simple checks that can help identify the problem.
Start by checking if the refrigerator is in lockout mode. In this situation, the lights may still turn on, but the compressor will not operate. The first step is performing a hard reset by disconnecting all power sources to the refrigerator, including shore power, solar input, and generators. Leave the unit without power for 5–10 minutes before reconnecting.
If the issue continues after the reset, the next step is to measure the amperage draw at the compressor. This reading can help determine what may be happening inside the system:
• 0 amps may indicate no power reaching the refrigerator, possibly due to a blown fuse or wiring issue.
• 0.5–2.5 amps may suggest low refrigerant levels.
• 3–14 amps is the normal operating range for the compressor.
• 15 amps or higher could indicate the compressor motor is locked up and the refrigerator may need replacement.
The video also explains how to test the compressor using the compressor control module. By placing a jumper wire between the C and T terminals, you can bypass the thermostat signal and attempt to start the compressor directly.
These troubleshooting steps can help you better understand what is happening with your RV fridge and determine the next steps for repair or replacement.
Watch the full video for a detailed walkthrough of testing the compressor on the FCR16DCASA Furrion refrigerator.
Shop our store at lippert.com/rv-camping/appliances/refrigerators
For technical resources and support, visit support.lci1.com/, and don’t forget to subscribe to our channel!