Uploaded December 2013 | Updated November 2026, 3 hours ago
Recording on a high-resolution multielectrode array of electrophysiological activity in a rat cortico-hippocampal slice under (A) spontaneous conditions (150 milliseconds); (B) immediately after perfusion with 4-Aminopyridine (1100 milliseconds) and (C) 15 min after perfusion of 4AP (2200 milliseconds). Field potential propagations and spiking activities are recorded mainly in the hippocampal circuit that covers almost the whole active area of the chip. The recording was performed by 4096 electrodes with inter-electrode spacing of 21 µm and with a sampling frequency of 7kHz per electrode. The raw signals (extracellular potentials) recorded by the 64x64 electrode array are visualized in a false color-map as indicated in the movie.
The recording was performed using the 3Brain instrumentation (www.3brain.com) at the NETS3 Laboratory of the Istituto Italiano di Tecnologia (IIT, Genova) and in collaboration with Franco Ortiz and Prof. Rafael Gutiérrez (Centro de Investigación y Estudios Avanzados del Insituto Politecnico Nacional, Mexico).
Link to HD-MEA - BioCAM DupleX: 3brain.com/products/single-well/biocam-duplex
HD-MEA Chips: 3brain.com/products/single-well/hd-mea
Contact our neuroscientist team for any questions: 3brain.com/contact
Recording on a high-resolution multielectrode array of electrophysiological activity in a rat cortico-hippocampal slice under (A) spontaneous conditions (150 milliseconds); (B) immediately after perfusion with 4-Aminopyridine (1100 milliseconds) and (C) 15 min after perfusion of 4AP (2200 milliseconds). Field potential propagations and spiking activities are recorded mainly in the hippocampal circuit that covers almost the whole active area of the chip. The recording was performed by 4096 electrodes with inter-electrode spacing of 21 µm and with a sampling frequency of 7kHz per electrode. The raw signals (extracellular potentials) recorded by the 64x64 electrode array are visualized in a false color-map as indicated in the movie.
The recording was performed using the 3Brain instrumentation (www.3brain.com) at the NETS3 Laboratory of the Istituto Italiano di Tecnologia (IIT, Genova) and in collaboration with Franco Ortiz and Prof. Rafael Gutiérrez (Centro de Investigación y Estudios Avanzados del Insituto Politecnico Nacional, Mexico).
Link to HD-MEA - BioCAM DupleX: 3brain.com/products/single-well/biocam-duplex
HD-MEA Chips: 3brain.com/products/single-well/hd-mea
Contact our neuroscientist team for any questions: 3brain.com/contact