Introduction to the SEM - Scanning Electron Microscope - Hitachi S-4800 - Part 1 @Ken_Sweden
Introduction to the SEM - Scanning Electron Microscope - Hitachi S-4800 - Part 1  @Ken_Sweden
Uploaded May 2025 | Updated September 2026, 1 week ago
This video provides a complete step-by-step walkthrough for cleanroom training and operating the S-4800 Scanning Electron Microscope (SEM). It is for students, researchers, and first-time users.

Key points covered include:

1. Cleanroom Preparation to Prepare for and ALWAYS follow:
• Wear a lab coat, gloves, shoe covers, and eye protection (all provided in the lab).
• Follow cleanroom behavior protocols to maintain a contaminant-free environment.
• Always leave the microscopy laboratory in a nicer (cleaner) state than it was when you arrived.

2. Entering the Cleanroom
• Properly use and dispose of shoe covers.
• Move through clean zones to prevent particle contamination.
• If you have very messy shoes, leave them outside.

3. Filling the Cold Trap with Liquid Nitrogen
• Demonstration of correct filling procedure.
• Listen for the change in sound to know when it’s full—avoid overfilling. About 0.5 L is needed.
• Safety first: don’t pour liquid nitrogen on the machine or on yourself.
• Always use eye protection when working with liquid nitrogen.

4. Starting the SEM System
• Power is always on for the 4800 SEM, and check system status (e.g., idle mode).
• No need to start the microscope.

5. Using the Internal Camera
• Use the built-in camera for accurate sample positioning.
• Move slowly and carefully to avoid mistakes and dropping your sample inside the vacuum chamber.

6. Handling and Inserting Samples
• Clean sample handling techniques.
• Insert samples gently to protect the instrument and sample.
• More information on this in the next video.

7. Filling Out the Logbook
• Log your session start time, user name, and any relevant notes.
• Logging is mandatory: it helps staff track system use and plan maintenance.
• The SEM is not considered “in use” unless it’s properly logged.
• The SEM is booked (reserved via the LIMS system).

#sem #microscope #imaging

8. Why It Matters
• Ensures high-quality SEM imaging.
• Extends instrument lifetime and reduces repair costs
Introduction to the SEM - Scanning Electron Microscope - Hitachi S-4800 - Part 1100% sealed Torqueflite transmission pan - LubeLocker instructions - JEEP Wrangler YJ : Ep 12New Cushioning EVA foam in your boat – How to cut and glue!Dryer Error E90 on Bosch tumble dryer - Fixed problem!What would you do? Beer in Japan!Brake drum - POR 15 paint stripping - rust conversion and powder coat - JEEP Wrangler YJ : Ep 25Cleaning Italian Espresso Machine! DIY - instructions - guide - tutorial!LED installation guide for Speedo and Tachometer - JEEP Wrangler YJ : Ep 24Removing the fuel tank - Jeep Wrangler YJ : Ep. 28Cellulose nanofiber silica aerogelsSelecting the right transmission gasket - OEM Rubber, FarPak or LubeLocker - JEEP Wrangler YJ : Ep 9A cheap way to a clean change of your transmission fluid - JEEP Wrangler YJ : Ep 3