Uploaded September 2023 | Updated November 2026, 5 days ago
This short video demonstrates how to use the Sandler Non-Invasive Stability Margin (NISM) measurement algorithm on impedance in the frequency domain to determine control loop stability. This method also provides a way of quantifying the maximum stable case of flat impedance.
Regulated power delivery requires a control loop, and if not designed properly, a control loop can easily go unstable and oscillate. Critical power delivery systems for automotive and space applications all have requirements for testing the stability of all power delivery control loops; however, traditional methods are not always possible. Traditional methods, like Bode plots, require access to the control loop for open and closed loop measurements. The new NISM method only requires an external output impedance measurement of the regulated power delivery at the feedback point.
00:00 Introduction
02:55 How to use impedance to calculate voltage regulator stability margin
05:15 How to run the Sandler NISM algorithm in Keysight's PathWave Advanced Design System (ADS)
06:50 Using regulator ON/OFF states to find the active inductance peak
07:40 How the Sandler NISM stability algorithm also works for input filtering
09:08 Summary
Download the project files referred to in this video:
keysight.com/find/ads-how-to-nism
Apply for a free trial of ADS:
keysight.com/find/mytrial.si.vi
For more information about Picotest:
picotest.com
Watch more in this video series:
youtube.com/playlist?list=PLtq84kH8xZ9FNXAsf-odoGNe6h5A6D3in
This short video demonstrates how to use the Sandler Non-Invasive Stability Margin (NISM) measurement algorithm on impedance in the frequency domain to determine control loop stability. This method also provides a way of quantifying the maximum stable case of flat impedance.
Regulated power delivery requires a control loop, and if not designed properly, a control loop can easily go unstable and oscillate. Critical power delivery systems for automotive and space applications all have requirements for testing the stability of all power delivery control loops; however, traditional methods are not always possible. Traditional methods, like Bode plots, require access to the control loop for open and closed loop measurements. The new NISM method only requires an external output impedance measurement of the regulated power delivery at the feedback point.
00:00 Introduction
02:55 How to use impedance to calculate voltage regulator stability margin
05:15 How to run the Sandler NISM algorithm in Keysight's PathWave Advanced Design System (ADS)
06:50 Using regulator ON/OFF states to find the active inductance peak
07:40 How the Sandler NISM stability algorithm also works for input filtering
09:08 Summary
Download the project files referred to in this video:
keysight.com/find/ads-how-to-nism
Apply for a free trial of ADS:
keysight.com/find/mytrial.si.vi
For more information about Picotest:
picotest.com
Watch more in this video series:
youtube.com/playlist?list=PLtq84kH8xZ9FNXAsf-odoGNe6h5A6D3in