"High Temperature Concentrating Solar and Chloride Salt Systems" by Kenneth Armijo of SNL (Sandia National Laboratories).

720°C CI Molten Salt Key Challenges:
- U.S. DOE SETO focus of developing thermal transport systems capable of operating temperatures greater-than 700°C and integration with advanced, high-efficiency power cycles.
- Materials and Manufacturing - Solutions to reduce the cost of manufacturing
CSP components. "Receiver & components: piping, pumps, tower structure, insulation, heat tracing, headers, and valves"
- To attain CSP capital reduction, need to improve performance of materials & reduce CSP component manufacturing costs.
- Materials compatibility up to 740°C
- Leak & Freeze Protection
- Proper Controls and Ullage Gas System Integration
- Higher-than-expected salt vapor pressure
- High salt vapor freezing phenomena

Molten Salt Test Loop (MSTL)
• MSTL developed to allow industrial customers and researchers to test molten salts under flow, over range of temps/ flow rates for various components & heated systems.
• Since September 2017, MSTL has not been used where the system is currently off-line and salt freezing has occurred.
• Constr. of MSTL today would cost 1.5-2 times (-$21M more than original 2010 costs.
• Although small test loops are used to prove concepts, they are not necessarily scalable to commercial plant sizes.

Molten Salt Test Loop Characteristics:
• Salt flow through each test stand is set by a test stand flow valve and the pump.
• System salt pressure is set by the backpressure valve and the pump.
Salt temperature is set by the furnace and the salt cooler.
•The primary purpose of the cooler is to remove pump work and heat input.

(Phase 2 Re-Start Expected 2024, however DOE SETO Requires Immediate Users for Final Restart Funding in FY24/FY25.)

750°C Chloride MS Test Loop:
• Halide MS test loop capable of 750°C and 11 Bar thermodynamic flow screening evaluations
• Multiple heat trace controllers with redundancies
• 2 in. Inconel 625 piping (at a 5-10 deg drop) with N, UHP ullage gas
• Multiple heat trace zones for each valve
• Small pump with individual salt buffer tank, drawing from sump tank
• system uses control valves in combination with high temperature pressure sensors to calculate salt flow coming from the salt pump, calculate valve Cv

Kairos/SNL Power Isothermal Batch FLiNaK Flow Unit:
• Cold commissioning completed ( Leak check , Heater run-ins, Vessel bake-out )
• Hot Commissioning completed.
•Ramped heaters up to 600C
• Verification of system operations
• Completed transfer from vessel
V10 to vessel V20.
• 3 FCV Testing On-Going
• Gen 3 Prototype
• Bellows Valve
• Quick-Change Packing Valve

Last talk of 2023-10-25 at ORNL MSRW 2023. That's day 1 of a 2 day conference.

ThoriumRemix.com Thorium & MSR & Nuclear assets used in Thorium Remix project.
High Temperature Concentrating Solar and Chloride Salt Systems by Kenneth Armijo @ ORNL MSRW 2023Thermophysical Modeling of Molten Salts - Dianne Ezell @ ORNL MSRW 2021Dr. Richard Steeves - Alvin Weinbergs book The First Nuclear Era @ TEAC10Trump 2024-06-27 debating Biden 2024-04-19 on climate changeSalt Loop Irradiation - Charles Forsberg @ ORNL MSRW 2021Molten-Salt Lubricated Bearings (NEUP Project) by Minghui Chen of UNM @ TEAC11Minnesota Tritium Perspective ExplainedPathways to Clean Energy Future - Christine King of GAIN @ ORNL MSRW 2021Jess Gehin @ TEAC2Trump on Nuclear Power: Revisit RegulationsDaniel Cooper the Chief Chemist of Seaborg Technologies @ ThEC2018Canadian Nuclear - CANDU are Creating Medical Isotopes