GIGABYTE Servers Two-Phase Cooling using 3M Novec (CES 2017) @anandshimpi
GIGABYTE Servers Two-Phase Cooling using 3M Novec (CES 2017)  @anandshimpi
Uploaded January 2017 | Updated November 2026, 3 hours ago
anandtech.com

In the land of immersed systems, there are many way of doing things. A few intrepid users have gone with oil, still using a CPU cooler but relying on the liquid cycling throughout the system to remove heat energy. Going back over a decade and a half, I recall a system whereby a 35W processor was immersed, without a heatsink, into a bath of a 3M hydrocarbon with a modest boiling point, around 45C, which was then combined in a sealed system with an external thermal electric cooler to initiate the recycling. The demonstration by GIGABYTE at CES this year with a fully-embedded system mainly uses the latter technique.

So to keep things under wraps, 3M's Novec line of liquids involve a full array of halogenated hydrocarbon compounds for different uses, and the variant of Novec that is under use here was not specified. However a quick search turns up a likely candidate in Novec 72DA.

Novec 72DA liquid is a solution of 70% 1,2-trans-dichloroethylene, 4-16% ethyl nonafluorobutyl ether, 4-6% ethyl nonafluoroisobutyl ether and trace other similar methyl variants. The liquid has a boiling point of 45ºC at very low viscosity (0.4 cP, compared to 0.89 cP for water), but also a low specific heat capacity (1.33 J/g/K, compared to 4.184 for water). Typically water cooling (with blocks) with the high heat capacity is preferred, but at 1.33 J/g/K for the main ingredient in Novec is interesting: take a CPU that uses 140W, and in 60 seconds it will change 8400J of energy from electricity to heat. That would raise one kg of liquid (0.8 liters, due to 1.257 kg per liter for density) up by 7.24ºC. Thus it would take around 3 minutes from a slightly chilled start to create one kg of the main component of Novec to boiling point. If we add in the latent heat of vaporization, or the energy it takes to transform a chemical from a liquid at boiling point to vapor, then we need another 350 kJ/kg, or 41.67 minutes.
GIGABYTE Servers Two-Phase Cooling using 3M Novec (CES 2017)The AnandTech Podcast #040: CES 2017, Kaby Lake, Snapdragon 835Googles new Confidential Virtual MachinesThe AnandTech Podcast #002Galaxy S7 Review: Xperia X Performance 1080p30Galaxy Note 5 720p120 (iPhone 6s 720p240)Synaptics Android Wear Fingerprint ScannerDisneyland Xbox One XiPhone 6s 1080p30 (Compare with Note 5)The Jim Keller Interview[AnandTech] ROG Avalon 30-second Motherboard Teardown (Silent)AnandTech at Hot Chips 2018: Day One Overview
AnandTech |

GIGABYTE Server's Two-Phase Cooling using 3M Novec (CES 2017)

SHARE TO X SHARE TO REDDIT SHARE TO FACEBOOK WALLPAPER