Uploaded January 2025 | Updated November 2026, 2 days ago
Calibration is not the same as adjustment. Learn what calibration really means and when to use field or lab calibration.
▶ Need your instruments calibrated in the field or matched to their sensors? We can help: realpars.com/solutions/instrumentation?utm_source=youtube&utm_medium=video&utm_campaign=instrumentation&utm_content=industrial-calibration
▶ For companies, train your whole team with RealPars Business: realpars.com/business?utm_source=youtube&utm_medium=video&utm_campaign=business&utm_content=industrial-calibration
▶ For individuals, learn industrial automation at your own pace: realpars.com/?utm_source=youtube&utm_medium=video&utm_campaign=individual&utm_content=industrial-calibration
Chapters:
0:00 Intro
1:13 Calibration vs adjustment
1:54 What calibration really means
3:09 When you make an adjustment
3:32 Why we calibrate instruments
3:47 Field calibration of a temperature transmitter
4:43 When the sensor is the problem
5:24 Calibrating an RTD
6:17 Lab or factory calibration
7:25 Precision and industry standards
8:04 Summary
==========================
People often use calibration and adjustment as if they mean the same thing. They are related, but they are not the same. Calibration means you apply a known standard to the input of a device and compare its output with the expected value. Adjustment is what you do after, if the error is too big, like setting the zero and span on a transmitter.
We calibrate because instruments drift over time. In the field example, a process calibrator simulates an RTD and we check a 4 to 20 mA temperature transmitter at 0, 25, 50, 75 and 100 percent of its range. If the readings are inside the tolerance, nothing needs to change. If not, we adjust zero and span.
But a simulator does not show how the real sensor behaves. An RTD is checked in a temperature bath or dry block against a known temperature. You cannot adjust an RTD itself, so you correct for it in the transmitter, or in the PLC or DCS. Each RTD has its own Callendar-Van Dusen coefficients, so in a lab or factory calibration the transmitter can be matched to the exact sensor. Lab calibration is used where precision and traceability matter, like pharma and food, and labs are often accredited to ISO/IEC 17025.
Courses mentioned in the video:
Temperature transmitters: realpars.com/courses/temperature-transmitter
Master RTDs: realpars.com/courses/introduction-to-rtd
▶ Read the full article: realpars.com/blog/industrial-calibration
==========================
Watch next:
What is Sensor Calibration?: youtube.com/watch?v=n_lZCIA25aI
Process Calibrator Explained, Types, Source and Simulate: youtube.com/watch?v=dzQYv2m6ApA
Temperature Transmitter Explained, Wiring and Calibration: youtube.com/watch?v=Kq22wxqzJ7g
RTD Sensor Explained, How an RTD Works: youtube.com/watch?v=7nsIJ5fOLJ8
==========================
Subscribe for new videos: youtube.com/@realpars?sub_confirmation=1
Follow us on LinkedIn: linkedin.com/company/realpars
Follow us on Instagram: instagram.com/realparsdotcom
Like us on Facebook: facebook.com/therealpars
Follow us on X: https://x.com/realpars
#Calibration #Instrumentation #RealPars
Calibration is not the same as adjustment. Learn what calibration really means and when to use field or lab calibration.
▶ Need your instruments calibrated in the field or matched to their sensors? We can help: realpars.com/solutions/instrumentation?utm_source=youtube&utm_medium=video&utm_campaign=instrumentation&utm_content=industrial-calibration
▶ For companies, train your whole team with RealPars Business: realpars.com/business?utm_source=youtube&utm_medium=video&utm_campaign=business&utm_content=industrial-calibration
▶ For individuals, learn industrial automation at your own pace: realpars.com/?utm_source=youtube&utm_medium=video&utm_campaign=individual&utm_content=industrial-calibration
Chapters:
0:00 Intro
1:13 Calibration vs adjustment
1:54 What calibration really means
3:09 When you make an adjustment
3:32 Why we calibrate instruments
3:47 Field calibration of a temperature transmitter
4:43 When the sensor is the problem
5:24 Calibrating an RTD
6:17 Lab or factory calibration
7:25 Precision and industry standards
8:04 Summary
==========================
People often use calibration and adjustment as if they mean the same thing. They are related, but they are not the same. Calibration means you apply a known standard to the input of a device and compare its output with the expected value. Adjustment is what you do after, if the error is too big, like setting the zero and span on a transmitter.
We calibrate because instruments drift over time. In the field example, a process calibrator simulates an RTD and we check a 4 to 20 mA temperature transmitter at 0, 25, 50, 75 and 100 percent of its range. If the readings are inside the tolerance, nothing needs to change. If not, we adjust zero and span.
But a simulator does not show how the real sensor behaves. An RTD is checked in a temperature bath or dry block against a known temperature. You cannot adjust an RTD itself, so you correct for it in the transmitter, or in the PLC or DCS. Each RTD has its own Callendar-Van Dusen coefficients, so in a lab or factory calibration the transmitter can be matched to the exact sensor. Lab calibration is used where precision and traceability matter, like pharma and food, and labs are often accredited to ISO/IEC 17025.
Courses mentioned in the video:
Temperature transmitters: realpars.com/courses/temperature-transmitter
Master RTDs: realpars.com/courses/introduction-to-rtd
▶ Read the full article: realpars.com/blog/industrial-calibration
==========================
Watch next:
What is Sensor Calibration?: youtube.com/watch?v=n_lZCIA25aI
Process Calibrator Explained, Types, Source and Simulate: youtube.com/watch?v=dzQYv2m6ApA
Temperature Transmitter Explained, Wiring and Calibration: youtube.com/watch?v=Kq22wxqzJ7g
RTD Sensor Explained, How an RTD Works: youtube.com/watch?v=7nsIJ5fOLJ8
==========================
Subscribe for new videos: youtube.com/@realpars?sub_confirmation=1
Follow us on LinkedIn: linkedin.com/company/realpars
Follow us on Instagram: instagram.com/realparsdotcom
Like us on Facebook: facebook.com/therealpars
Follow us on X: https://x.com/realpars
#Calibration #Instrumentation #RealPars










