Uploaded August 2023 | Updated November 2026, 10 hours ago
In this EPicks, Eleanor J. Jones (Centre of Metabolism, Ageing and Physiology (COMAP), MRC-Versus Arthritis Centre for Musculoskeletal Ageing Research, National Institute for Health Research (NIHR) Nottingham Biomedical Research Centre, University of Nottingham, Nottingham, UK) talks about her latest research into 'Acute adaptation of central and peripheral motor unit features to exercise-induced fatigue differs with concentric and eccentric loading'.
Find out more in Experimental Physiology:
Acute adaptation of central and peripheral motor unit features to exercise-induced fatigue differs with concentric and eccentric loading
Eleanor J. Jones, Yuxiao Guo, Eduardo Martinez-Valdes, Francesco Negro, Daniel W. Stashuk, Philip J. Atherton, Bethan E. Phillips, Mathew Piasecki
108(6), pp. 827-837
physoc.onlinelibrary.wiley.com/doi/10.1113/EP091058
Transcript:
Hello. I’m Eleanor and I am a postdoctoral researcher in the Centre of Metabolism, Ageing and Physiology at the University of Nottingham.
In our paper we aimed to determine the loading-specific response of vastus lateralis motor unit features using intramuscular and high-density surface electromyography before and after a functional stepping task. This task employed bilateral concentric and eccentric contractions performed to exhaustion.
The motor unit describes the motor neuron, all associated neuromuscular junctions and muscle fibres it supplies. It is a key component involved in the control of muscle force production through altering recruitment and firing properties. But previous research demonstrates mixed findings on changes in motor unit properties following performance fatigue where muscle force output is reduced, and this may depend on the mode of contraction undertaken.
We found that motor unit features respond to fatigue in a contraction dependent manner. Despite similar reductions in strength after fatiguing exercise, motor unit firing rate responded opposingly following concentric and eccentric contractions. These findings were replicated when directly tracking a subset of identified motor units before and after the exercise.
Using needle electrodes inserted into the muscle during contractions, we found that transmission instability at the neuromuscular junction increased following both exercise modes was more variable after exercise. We also analysed features of the motor unit potentials representing markers of fibre membrane excitability, and found they were only altered following the more metabolically demanding concentric loading.
Differences in the motor unit response to concentric and eccentric induced fatigue are important when considering exercise training protocols, particularly in populations with musculoskeletal limitations. This has implications for interventional strategies intended to target neural input and motor unit function. This may also have translational relevance in understanding conditions such as sarcopenia and cancer where exercise tolerance due to muscle fatigue and weakness present a challenge.
In this EPicks, Eleanor J. Jones (Centre of Metabolism, Ageing and Physiology (COMAP), MRC-Versus Arthritis Centre for Musculoskeletal Ageing Research, National Institute for Health Research (NIHR) Nottingham Biomedical Research Centre, University of Nottingham, Nottingham, UK) talks about her latest research into 'Acute adaptation of central and peripheral motor unit features to exercise-induced fatigue differs with concentric and eccentric loading'.
Find out more in Experimental Physiology:
Acute adaptation of central and peripheral motor unit features to exercise-induced fatigue differs with concentric and eccentric loading
Eleanor J. Jones, Yuxiao Guo, Eduardo Martinez-Valdes, Francesco Negro, Daniel W. Stashuk, Philip J. Atherton, Bethan E. Phillips, Mathew Piasecki
108(6), pp. 827-837
physoc.onlinelibrary.wiley.com/doi/10.1113/EP091058
Transcript:
Hello. I’m Eleanor and I am a postdoctoral researcher in the Centre of Metabolism, Ageing and Physiology at the University of Nottingham.
In our paper we aimed to determine the loading-specific response of vastus lateralis motor unit features using intramuscular and high-density surface electromyography before and after a functional stepping task. This task employed bilateral concentric and eccentric contractions performed to exhaustion.
The motor unit describes the motor neuron, all associated neuromuscular junctions and muscle fibres it supplies. It is a key component involved in the control of muscle force production through altering recruitment and firing properties. But previous research demonstrates mixed findings on changes in motor unit properties following performance fatigue where muscle force output is reduced, and this may depend on the mode of contraction undertaken.
We found that motor unit features respond to fatigue in a contraction dependent manner. Despite similar reductions in strength after fatiguing exercise, motor unit firing rate responded opposingly following concentric and eccentric contractions. These findings were replicated when directly tracking a subset of identified motor units before and after the exercise.
Using needle electrodes inserted into the muscle during contractions, we found that transmission instability at the neuromuscular junction increased following both exercise modes was more variable after exercise. We also analysed features of the motor unit potentials representing markers of fibre membrane excitability, and found they were only altered following the more metabolically demanding concentric loading.
Differences in the motor unit response to concentric and eccentric induced fatigue are important when considering exercise training protocols, particularly in populations with musculoskeletal limitations. This has implications for interventional strategies intended to target neural input and motor unit function. This may also have translational relevance in understanding conditions such as sarcopenia and cancer where exercise tolerance due to muscle fatigue and weakness present a challenge.










