DBX 1046 and 1066 Compressor/Limiter Display & Overheating fixes. @Zenodilodon
DBX 1046 and 1066 Compressor/Limiter Display & Overheating fixes.  @Zenodilodon
Uploaded November 2018 | Updated November 2026, 2 days ago
Video on the process of repairs and alterations I did on the DBX professional audio compressor/limiters models 1066 and 1046.

Most of the problems with these models are the connections between the main board and the display board and those connections where directly soldered. The 1046 also has extreme heat production issues with the 2 regulators on the display board and thus are prone to overheating. heat spreaders where placed on those and 30 mm fans where installed. The fans come a leg of the transformer which is 21v AC rectified and smoothed to get 27 v DC, The fans are in series to one another and 120 ohm resistor. Each fan is then on a voltage dividing block with limiting resistors to each of around 100 ohms. This brings each fans voltage to 7 volts nominal as to not be so noisy. Questions and comments are welcome.
DBX 1046 and 1066 Compressor/Limiter Display & Overheating fixes.An Expert Dissection of a NEC VT540K Video ProjectorJenLas D2.3 Thin-Disk Laser Manufactured By JenoptikHow to take apart a zune model 1090 and upgradeFrankensteining a Uniphase  μGreen Laser Model 4301-010RTI ATTO Show Laser RepairRepairing 6 Show Lasers Part 8, The 7th Laser BonusDebunking The Derval Techrachomatic Test.Repairing 2x Lightspace Venus RGB22 Watt Show LasersThe 1.8 inch Toshiba Hard Drive 30 GB,  bad   power hack demo and working footage.Repairing Bad Blue Lasers In An ArtFox Show LaserBuilding A Compact Compact Quad Galvo Show Laser
Zenodilodon |

DBX 1046 and 1066 Compressor/Limiter Display & Overheating fixes.

SHARE TO X SHARE TO REDDIT SHARE TO FACEBOOK WALLPAPER