@TheUbuntuGuy
  @TheUbuntuGuy
Mark Furneaux | CyberPower UPSes Contain Conductive Yellow Glue of Death (+ Bonus Rev. 2 Dim LCD Fix) @TheUbuntuGuy | Uploaded May 2021 | Updated October 2024, 12 hours ago.
The CP1500PFCLCD and CP1350PFCLCD UPSes of at least rev 1 and rev 2 over the last 10 years contain yellow glue which becomes conductive and corrosive over time which can cause sometimes fiery failure. Also included is some ramblings of the notorious rev 2 LCD backlight failures and my attempt are rebuilding the backlight.

Timestamps:
0:00 Intro
8:18 Taking the unit apart
10:47 Glue locations
14:09 Rev 2 differences
19:05 LCD backlight fix

I do have access to a rev 3 unit, but have not taken it apart yet. I will update this once I know if it is also affected.

I have a second channel:
youtube.com/channel/UCN3Dgu6CVBcecDkc5DmIIqw
CyberPower UPSes Contain Conductive Yellow Glue of Death (+ Bonus Rev. 2 Dim LCD Fix)Digital Audio: The BasicsRandom Teardown #006: Honeywell RTH230B ThermostatReview of the Doogee X5S $60 4G PhoneDestroying A Dangerous Chinese Mains Power CableRepairing a Lightning Stricken Plasma TVReview Of The BlitzWolf BW-VR1 Virtual Reality Headset (Cardboard Compatible)How I Backup My DataUnexpected Saturday Project: A Single Digit Nixie ClockReview of the Etekcity Soil Moisture Meter1964 Electrohome Phonola Restoration: Part 3Teardown of the Hanmatek Electric Screwdriver