Cooker circuits for domestic properties. Protective device, cable size, and what can be connected to the end of it.
In virtually all cases, a 32A MCB and 4mm² cable is suitable for cooking devices up to 15kW.
For connecting to the appliance(s), either 4mm² or 2.5mm² H07RN-F flex depending on the connected load.