Uploaded November 2026 | Updated November 2026, 8 hours ago
Lionel Hercot of Cisco presents Cisco's full-stack approach to rack-scale AI infrastructure. He covers reference architectures for clusters from 256 to hundreds of thousands of GPUs, the expanded Supermicro server and liquid cooling portfolio, Silicon One and Spectrum-X-based Nexus switching, unified management through Cisco Cloud Control, and Cisco Validated Infrastructure Services (CVIS). This session was recorded at Tech Field Day at Supercomputing 2026, and it shows how Cisco wants to take customers from ordering a cluster to generating their first tokens.
Hercot explained that three design factors decide which reference architecture fits a customer: the type of system, the scale, and the use case. The smallest design starts at 256 GPUs and draws about 500 kilowatts. He estimated about 2.2 megawatts for a 1,000-GPU cluster. The Cisco reference architecture (CRA) uses Silicon One on both the front-end and back-end networks. The NVIDIA Cloud Partner (NCP) reference architecture instead uses Nexus 9100 switches with Spectrum-X on the back end. Supermicro servers are now sold as Cisco SKUs, and Cisco handles the first call for support and RMAs. The lineup includes HGX B300, liquid-cooled Rubin systems, GB300 and Vera Rubin NVL72 racks, and Supermicro liquid cooling. On the switching side, today's 64-port 800G G200 systems will be joined in 2027 by 1.6T G300 switches in air- and liquid-cooled versions. Hercot noted that a 1,000-GPU back end needs roughly 4,000 optics and 8,000 cables.
Cisco Cloud Control brings Nexus Dashboard, Hyperfabric, servers, and coolant distribution unit (CDU) telemetry into a single view. It also adds automated health assertions, AI Canvas, MCP servers, and a Studio and marketplace for custom integrations. CVIS is Cisco's own version of NVIDIA's validated infrastructure services. It gets involved at the pre-sales design stage and gives partners a toolkit that checks cabling and automates configuration. It then validates the finished cluster so customers can earn NVIDIA NCP qualification and resell GPU capacity. Cisco is also building its own performance cluster to tune these reference architectures before customers deploy them.
Presented by Lionel Hercot of Cisco. Recorded live at Tech Field at Supercomputing 2026 in Chicago, IL on November 17. Watch the entire presentation at techfieldday.com/appearance/cisco-presents-at-tech-field-day-at-sc26 or visit techfieldday.com/event/sc26 or cisco.com for more information.
Lionel Hercot of Cisco presents Cisco's full-stack approach to rack-scale AI infrastructure. He covers reference architectures for clusters from 256 to hundreds of thousands of GPUs, the expanded Supermicro server and liquid cooling portfolio, Silicon One and Spectrum-X-based Nexus switching, unified management through Cisco Cloud Control, and Cisco Validated Infrastructure Services (CVIS). This session was recorded at Tech Field Day at Supercomputing 2026, and it shows how Cisco wants to take customers from ordering a cluster to generating their first tokens.
Hercot explained that three design factors decide which reference architecture fits a customer: the type of system, the scale, and the use case. The smallest design starts at 256 GPUs and draws about 500 kilowatts. He estimated about 2.2 megawatts for a 1,000-GPU cluster. The Cisco reference architecture (CRA) uses Silicon One on both the front-end and back-end networks. The NVIDIA Cloud Partner (NCP) reference architecture instead uses Nexus 9100 switches with Spectrum-X on the back end. Supermicro servers are now sold as Cisco SKUs, and Cisco handles the first call for support and RMAs. The lineup includes HGX B300, liquid-cooled Rubin systems, GB300 and Vera Rubin NVL72 racks, and Supermicro liquid cooling. On the switching side, today's 64-port 800G G200 systems will be joined in 2027 by 1.6T G300 switches in air- and liquid-cooled versions. Hercot noted that a 1,000-GPU back end needs roughly 4,000 optics and 8,000 cables.
Cisco Cloud Control brings Nexus Dashboard, Hyperfabric, servers, and coolant distribution unit (CDU) telemetry into a single view. It also adds automated health assertions, AI Canvas, MCP servers, and a Studio and marketplace for custom integrations. CVIS is Cisco's own version of NVIDIA's validated infrastructure services. It gets involved at the pre-sales design stage and gives partners a toolkit that checks cabling and automates configuration. It then validates the finished cluster so customers can earn NVIDIA NCP qualification and resell GPU capacity. Cisco is also building its own performance cluster to tune these reference architectures before customers deploy them.
Presented by Lionel Hercot of Cisco. Recorded live at Tech Field at Supercomputing 2026 in Chicago, IL on November 17. Watch the entire presentation at techfieldday.com/appearance/cisco-presents-at-tech-field-day-at-sc26 or visit techfieldday.com/event/sc26 or cisco.com for more information.