Last year, Kevin and I tested running some incandescent Christmas lights off diodes that reduce the power consumption by 1/2. The lights do operate at a slightly dimmer brightness, I'd say maybe a 30% reduction, but I think this is well worth the 50% reduction in operation cost. As an added bonus, this will also extend the lifespan of the bulbs which has become increasingly important this year now that the bulbs are no longer readily available for cheap.
I tested 1 diode connected to the heatsink for about 20 minutes with a 1500w load, which is around the maximum load one would receive in this use case. There was only about a 10 degree temperature rise, which is a lot less than I was expecting. I think we've proven the concept successful. Time will tell whether or not we need to add a fan to the apparatus for additional cooling. I'm thinking this will not be necessary.
I'm hoping this will end up reducing the operation cost of the display by more than half. The electricity cost per kWh around here increases the more you use. If this reduces the consumption by half, it may also keep the bill in one of the lower tiers, which will result in significantly more than half savings.
Last year, Kevin and I tested running some incandescent Christmas lights off diodes that reduce the power consumption by 1/2. The lights do operate at a slightly dimmer brightness, I'd say maybe a 30% reduction, but I think this is well worth the 50% reduction in operation cost. As an added bonus, this will also extend the lifespan of the bulbs which has become increasingly important this year now that the bulbs are no longer readily available for cheap.
I tested 1 diode connected to the heatsink for about 20 minutes with a 1500w load, which is around the maximum load one would receive in this use case. There was only about a 10 degree temperature rise, which is a lot less than I was expecting. I think we've proven the concept successful. Time will tell whether or not we need to add a fan to the apparatus for additional cooling. I'm thinking this will not be necessary.
I'm hoping this will end up reducing the operation cost of the display by more than half. The electricity cost per kWh around here increases the more you use. If this reduces the consumption by half, it may also keep the bill in one of the lower tiers, which will result in significantly more than half savings.






![1920s General Electric 236327 9 Whiz Fan with Custom Modification
An early 1920s General Electric 9 Whiz fan model 236327. Brass blades with dark green finish.
This was one of the first fans of this era I had in my collection. It came from EBAY back in the 2000s, when prices on there were still within reason (those days are long gone). I recall replacing the wall to switch cord, lubricating the motor, and polishing the blades when I got it. The paint is in remarkable condition considering its over 100 years old.
These appear to be fairly common fans, but this one is unique has it had a custom modification done to it at some point. The base was cut in half and patched together using some type of rubber piece. I used to think this was factory, but very recently learned it is not. Whoever did it had the correct tools and knew how to use them. The metal is cut clean and even. The rubber piece is starting to weaken in the last few years, but in its defense, its been like this for at least the 20 years Ive owned it, and likely for much longer.
I suspect this was done to reduce noise or vibration as this isolates the motor from the part that sits on the table, but I find it hard to believe this was really necessary. This is a very quiet and smooth running fan, despite the blades being totally out of clock.
This is objectively a very good fan. It is quite powerful for the size and notably quiet. It pulls a modest amount of power as well; its surprisingly efficient considering how old the motor technology is and how early the design is.
The power factor of the motor is very high, around 0.94. I thought this was a shaded pole motor as I dont see a capacitor anywhere, but I find it hard to believe a shaded pole motor has that high of a power factor.
Specifications recorded during the demonstration, listed as [Power (watts) / Current (amps) / Power Factor / Air Flow Volume (CFM) / Efficiency (CFM/watt)].
110 Volts: [46 / 0.44 / 0.93 / 314 / 6.8].
120 Volts: [51 / 0.45 / 0.94 / 321 / 6.3]. 1920s General Electric 236327 9 Whiz Fan with Custom Modification](https://i.ytimg.com/vi/YNq6tXUmXBI/mqdefault.jpg)