Quick and dirty video of a 1500w GE Multi-Vapor metal halide lamp.
Arcstream instability can often be seen on brand new lamps which is caused by the discharge operating temporarily outside of its design envelope.
This is because the condensed metal halide salts have not yet migrated to the coldest part of the lamp and will cause the vapour pressure to be too high.
After several hours of running the salts will diffuse and the arc will stabilise.