I ponied up the pounds to purchase Hager’s ‘smart’ AFDD after seeing it on the stand at Elex earlier this month. Although I raised my monobrow at some of the statements Hager were making at the show (see prior video), I nonetheless expected this device to perform its basic job regardless of any additional whistles and bells Hager have stuffed into the package. As you’ll see, things didn’t go to plan. What do you make of it? Is this a failure of my testing or a problem with Hager’s product?
I'm not trying to place any cats among any pigeons here, so if you are attending Elex please don't give the Hager guys and gals a roasting about their wares based on this video. Ask them questions and politely engage with their representatives in a friendly fashion and make up your own mind on what they say. I've nothing against Hager... apart from their pricing sometimes... and I'm not out to cause them any aggro.
Errata:
In this video, I state my Siemens AFDD shows a triple-flash for earth leakage indication. While this is true of the single module Wylex/Crabtree branded AFDDs, this Siemens add-on unit only has a single flashing yellow light which flags a series arc, parallel arc or an earth leakage trip event.
The parallel arc test should be discounted. It's very hard to create a parallel arc in this kind of way and it was very much done on the fly. Later thought and further playing around showed it as flawed.
Links:
Linda and Me at Elex ‘23
youtu.be/vl0tM-kZqa0?si=2WFWgf5gXflh1y-Q
My first AFDD video from 2018
youtu.be/JRXFZHKGaXg
“The Arc Fault Detection Device… again.” – This video was a technical follow-up to the previous presentation and introduced my homemade arc fault tester and arc test chamber.
youtu.be/e0ElFaKc_e8
“The £1300 AFDD consumer unit” – Here I retrofit nine AFDDs into my old plastic Wylex board and discuss testing and fault finding on AFDD circuits.
youtu.be/YDGeyJnoqZQ
Affiliate links:
For a shout out in a future video, you can buy me a beer or cigar here or with the SuperThanks button:
buymeacoffee.com/dseselectric
£50 off YourTradeBase:
go.yourtradebase.com/refer/3M6F3301
SumUp credit/debit card processing:
http://r.sumup.com/referrals/oBF5S
Get £40 credit for switching to Zen Internet:
zen.mention-me.com/m/ol/rt4lh-david-savery
For web hosting, get £10 off at Krystal with the code DSESELECTRIC at checkout!
krystal.uk
Recycle your scrap cable at greencable.com - use referral code GREENCABLET1ZT when setting up an account and I'll get a tenner while you get a recycling bin delivered at no cost!
For more on my video content, refer to my OnlyFans page (not really an OnlyFans page):
dses.co.uk/index.php/news/244-onlyfans or at dses.tv
I ponied up the pounds to purchase Hager’s ‘smart’ AFDD after seeing it on the stand at Elex earlier this month. Although I raised my monobrow at some of the statements Hager were making at the show (see prior video), I nonetheless expected this device to perform its basic job regardless of any additional whistles and bells Hager have stuffed into the package. As you’ll see, things didn’t go to plan. What do you make of it? Is this a failure of my testing or a problem with Hager’s product?
I'm not trying to place any cats among any pigeons here, so if you are attending Elex please don't give the Hager guys and gals a roasting about their wares based on this video. Ask them questions and politely engage with their representatives in a friendly fashion and make up your own mind on what they say. I've nothing against Hager... apart from their pricing sometimes... and I'm not out to cause them any aggro.
Errata:
In this video, I state my Siemens AFDD shows a triple-flash for earth leakage indication. While this is true of the single module Wylex/Crabtree branded AFDDs, this Siemens add-on unit only has a single flashing yellow light which flags a series arc, parallel arc or an earth leakage trip event.
The parallel arc test should be discounted. It's very hard to create a parallel arc in this kind of way and it was very much done on the fly. Later thought and further playing around showed it as flawed.
Links:
Linda and Me at Elex ‘23
youtu.be/vl0tM-kZqa0?si=2WFWgf5gXflh1y-Q
My first AFDD video from 2018
youtu.be/JRXFZHKGaXg
“The Arc Fault Detection Device… again.” – This video was a technical follow-up to the previous presentation and introduced my homemade arc fault tester and arc test chamber.
youtu.be/e0ElFaKc_e8
“The £1300 AFDD consumer unit” – Here I retrofit nine AFDDs into my old plastic Wylex board and discuss testing and fault finding on AFDD circuits.
youtu.be/YDGeyJnoqZQ
Affiliate links:
For a shout out in a future video, you can buy me a beer or cigar here or with the SuperThanks button:
buymeacoffee.com/dseselectric
£50 off YourTradeBase:
go.yourtradebase.com/refer/3M6F3301
SumUp credit/debit card processing:
http://r.sumup.com/referrals/oBF5S
Get £40 credit for switching to Zen Internet:
zen.mention-me.com/m/ol/rt4lh-david-savery
For web hosting, get £10 off at Krystal with the code DSESELECTRIC at checkout!
krystal.uk
Recycle your scrap cable at greencable.com - use referral code GREENCABLET1ZT when setting up an account and I'll get a tenner while you get a recycling bin delivered at no cost!
For more on my video content, refer to my OnlyFans page (not really an OnlyFans page):
dses.co.uk/index.php/news/244-onlyfans or at dses.tv
![Landlord Electrical Inspections: Amendment 1
A five-minute follow-up to last week’s… oh FFS, how did it end up nearly an hour long??
Well, this is the last I shall be doing on condition reporting and the new landlord legislation. We’ll never all agree on what should be a C2/C3 even if the likes of NAPIT and ESF lay it down, so go do what you gotta do, but do it diligently!
Sorry about the camera angle, I was wearing no trousers while recording.
A point to clarify: There is what sounds like a contradiction in this video as I talk about 18th applying to new installations and alterations, then I later say you dont have to apply 18th to alterations as its not always practicable. The earlier statement should have read as new installations and additions as you apply 18th to the design of anything new, e.g. a new circuit, new socket spur etc. You dont always apply the requirements of the latest standard to alterations such as replacing a light fitting or changing the faceplate of an accessory as thats like-for-like. The point was there are electricians out there who are writing off circuits as C2 for their lack of RCD protection, then going to the next job where theyre happy to be paid to make alterations on equivalent circuits without demanding its updated. How can you write off a circuit as potentially dangerous on a report, yet certify the same kind of circuit as perfectly sound on a minor works?
On NAPITs C2 coding of cabling in walls, my thanks to Alex at Kanconnections who contacted NAPIT to ask about this. Their (abbreviated) response:
... Section D deals with the Extent and Limitations of the Inspection and Testing which then list the areas within the installation that have NOT been inspected unless agreed with the client.
... the inspector is not commenting on any cables concealed within the fabric of the building; therefore 5.10 and 5.12.3 & 4 should be marked as a Lim on the schedule of inspections.
The reasoning for assigning a C2 to the items 5.10 and 5.12.3 & 4 is when they have been observed within the premises and inspector has deemed to comment on the EICR regarding such cables, that there are dangers present to the users of the installation.
Related videos and content:
My previous video on this subject:
https://youtu.be/N_UN84w8brk
The £85 EICR
https://www.youtube.com/watch?v=BqNZugQ1kI0&t=1948s
… or my polite blog of the same:
https://www.dses.co.uk/index.php/personal-blog/215-cowboy-competition-8
Links:
On prescribed zones, the first image off Google was on none other than the great JW’s own website…. so I nicked it off him. He is credited though, and if you haven’t had a good old poke around on his Flameport site, then bally well go and do so:
https://www.flameport.com/wiring_regulations/BS7671_selected_subjects/zones_concealed_cables.cs4
*THAT* T-shirt for other Eighties fanbois:
https://www.redbubble.com/i/t-shirt/ulysses-31-by-luko3artist/48126058.88ZX2
NAPIT’s new guidance for landlords:
https://www.napit.org.uk/news/article/Landlords-questions-on-the-New-Electrical-Safety-Standards-answered.aspx
Landlord legislation for rental accommodation:
http://www.legislation.gov.uk/ukdsi/2020/9780111191934
Electrical Safety First (Best Practice Guides):
https://www.electricalsafetyfirst.org.uk/professional-resources/best-practice-guides/
The Competent Persons Register from The Department for Communities and Local Government have a database of all registered electricians. Note however that there is nothing to differentiate electrical installers from electrical inspectors, so if you find someone on here, check their bona fides for performing inspection work:
https://competentperson.co.uk/
The Registered Competent Persons database where you can look up sparkies accredited to be performing electrical inspections (meaning they have been validated for the right insurance and qualifications). Many installation electricians aren’t, but still offer the service often resulting in a nonsense report:
http://www.electricalcompetentperson.co.uk/
Government guidance:
https://www.gov.uk/government/publications/electrical-safety-standards-in-the-private-rented-sector-guidance-for-landlords-tenants-and-local-authorities/guide-for-landlords-electrical-safety-standards-in-the-private-rented-sector
NAPIT Codebreakers:
https://amzn.to/3f0yAF6 [affiliate link]
Radio Northenden:
https://mixlr.com/radio-northenden/showreel
https://twitter.com/RadioNorthenden
John Magnificent Smith: Electrical testing genius and (probably) not the bloke who got caught snaring squirrels and tickling their bollocks with the tip of his tongue:
https://www.youtube.com/channel/UCrqGS4IVNnhZINlL7SG_23Q
Actually, go easy on this asshole because... ah sod it… he shouldn’t have come here waving his cock in his hand. If anyone knows who he is, Id be interested to hear from them... from a legal point of view of course, seeing as hes going around on social media accusing me of cowboy work. Landlord Electrical Inspections: Amendment 1](https://i.ytimg.com/vi/drRTv9yyArs/mqdefault.jpg)