Uploaded February 2022 | Updated November 2026, 2 hours ago
This video is about the vintage Racal Dana 9300 RMS Voltmeter. It is a highly sensitive meter to measure AC voltages from 30 uV to 300V at frequencies of up to 20MHz and beyond. You can pick up for very little money and well suited to be integrated with digital meters.
The VISHAY capacitor part number for the 2200uF 50V type I used is MAL214651222E3
The replacement R14 is a 560 Ohm 1% metal film resistor TE-connectivity part LR0204F560R
You can support the channel by becoming a patron. patreon.com/user?u=45604138
As a patron you get early access to all my videos as well as exclusive content.
00:00 Comparison
04:59 DC out
06:06 Inside
08:07 Cap replacement
09:03 Function
12:44 9300B
13:10 R14 replacement
14:41 Test
15:20 Cal problems
18:28 Usage
20:51 Conclusion
PIC frequency counter mod: youtu.be/0BxpMm6SLoE
(be sure to look at the whole series of my videos on that counter)
This video is about the vintage Racal Dana 9300 RMS Voltmeter. It is a highly sensitive meter to measure AC voltages from 30 uV to 300V at frequencies of up to 20MHz and beyond. You can pick up for very little money and well suited to be integrated with digital meters.
The VISHAY capacitor part number for the 2200uF 50V type I used is MAL214651222E3
The replacement R14 is a 560 Ohm 1% metal film resistor TE-connectivity part LR0204F560R
You can support the channel by becoming a patron. patreon.com/user?u=45604138
As a patron you get early access to all my videos as well as exclusive content.
00:00 Comparison
04:59 DC out
06:06 Inside
08:07 Cap replacement
09:03 Function
12:44 9300B
13:10 R14 replacement
14:41 Test
15:20 Cal problems
18:28 Usage
20:51 Conclusion
PIC frequency counter mod: youtu.be/0BxpMm6SLoE
(be sure to look at the whole series of my videos on that counter)