DavidPoz
Series and Paralleling LiFePO4 Batteries 48v
updated
This is a heavy, transformer based inverter made for off grid and on grid both. This makes it a hybrid inverter. The Schneider XW PRO 6848 is battery based for any nominal 48V battery including lithium Iron Phosphate (LiFePO4).
In this video I put the inverter through rigorous load testing. Will it meet the spec in the manual? I throw power tools on it, water heaters, space heaters, etc. I try to load this XW PRO.
Chapters:
0:00 Intro
2:00 Overload Duration test on 240V
4:56 Power Tools on Inverter, 12" Miter Saw
7:59 Welding off grid
11:21 L1-N, Load Imbalance Testing
21:36 Conclusion
Download the Operation Guide for the XW PRO inverter here: solar.se.com/us/en/product/xw-pro-120-240v/#downloads
Scroll down and click on "User Documentation" then you can download the "XW PRO Owners Guide_990-91227"
PDP stands for Power Distribution Panel. Schneider makes two models of the PDP for the XW PRO inverter. There is a small, and large PDP. Both come with one 250A circuit breaker as a battery disconnect, and some AC circuit breakers. Both have a means to connect the single 250A breaker to one inverter.
The small PDP is made for one inverter only. It takes up less room, and costs a little less than the full size. As of this video, it is about $650 which makes it a real bargain if you know for certain you only need one inverter. This mounts under the inverter.
The large PDP takes up a little more room than the small PDP. It mounts next to the inverter, and comes with a wire-way that mounts under the inverter. The large PDP can accommodate up to 3 inverters allowing you to expand your system over time. As of this video, it costs about $1,200. It's only worth it if you know you will want more than one inverter (now or in the future).
---------------------------------------------------------------------------
Signature Solar Affiliate Links:
Schneider XW PRO inverter: signaturesolar.com/schneider-conext-xw-pro-6-8kw-inverter-charger-48v-120-240v/?ref=4_rHcgZ9x-TiF-
Schneider PDP, Large: signaturesolar.com/schneider-xw-power-distribution-panel-1-pole-250a-no-ac-breaker/?ref=4_rHcgZ9x-TiF-
Schneider PDP, Small: signaturesolar.com/schneider-xw-power-distribution-panel-mini-pdp/?ref=4_rHcgZ9x-TiF-
Schneider kit with inverters, PDP, and charge controllers: signaturesolar.com/bndl-dc-coupling-with-dual-inverter?ref=4_rHcgZ9x-TiF-
Complete Off grid kit: signaturesolar.com/complete-hybrid-solar-kit-schneider-dual-xw-pro-13-6kw-120-240v-output-30-72kwh-eg4-ll-v2-battery-powerwall-12710-watts-of-solar/?ref=4_rHcgZ9x-TiF-
Battery, 30.72 kWh, LiFePO4, EG4-LL, with cabinet and busbars: signaturesolar.com/eg4-ll-lithium-batteries-kit-48v-100ah-x-6-30-72kwh-6-server-rack-batteries-with-pre-assembled-enclosed-rack-with-door-wheelsac/?ref=4_rHcgZ9x-TiF-
Schneider Bundle with Mini-PDP: signaturesolar.com/bndl-dc-coupling-with-single-inverter?ref=4_rHcgZ9x-TiF-
---------------------------------------------------------------------------
Amazon Affiliate Links:
Power Meters (Din Rail): amzn.to/3A8v8Fj
SPD, Surge Protection Device: amzn.to/3U9YBWW
4/0 Lugs, UL: amzn.to/3SGwP3q
Wire Cutters: amzn.to/3sD0BLU
Wire Crimpers, Hydraulic: amzn.to/3gUUZtS
Service Entrance Connector: amzn.to/3FrNPXZ
Zip Ties, UL: amzn.to/3DF1ARX
Cable Tie Tool: amzn.to/3sIRXvs
Torque Screwdriver: amzn.to/3DS8nYR
Driver Bits for Electrical Terminals: amzn.to/3DIWS5L
“As an Amazon Associate I earn from qualifying purchases.”
---------------------------------------------------------------------------
Disclaimer:
Products in video may have been provided to David Poz, LLC at no cost for the purpose of the review. All views and opinions expressed are that of David Poz, LLC.
My videos are in no way intended to be instructional "how-to" lessons. I am simply documenting my project for informational purposes. Property damage, personal injury, or death may result, even when following manufacturer's instructions. I cannot be held liable for such damage or injury. It is YOUR OBLIGATION to ensure that you are complying with any local and federal laws as well as code and permit requirements.
David Poz, LLC
This is a heavy, transformer based inverter made for off grid and on grid both. This makes it a hybrid inverter. The Schneider XW PRO 6848 is battery based for any nominal 48V battery including lithium Iron Phosphate (LiFePO4).
PDP stands for Power Distribution Panel. Schneider makes two models of the PDP for the XW PRO inverter. There is a small, and large PDP. Both come with one 250A circuit breaker as a battery disconnect, and some AC circuit breakers. Both have a means to connect the single 250A breaker to one inverter.
The small PDP is made for one inverter only. It takes up less room, and costs a little less than the full size. As of this video, it is about $650 which makes it a real bargain if you know for certain you only need one inverter. This mounts under the inverter.
The large PDP takes up a little more room than the small PDP. It mounts next to the inverter, and comes with a wire-way that mounts under the inverter. The large PDP can accommodate up to 3 inverters allowing you to expand your system over time. As of this video, it costs about $1,200. It's only worth it if you know you will want more than one inverter (now or in the future).
---------------------------------------------------------------------------
Signature Solar Affiliate Links:
Schneider XW PRO inverter: signaturesolar.com/schneider-conext-xw-pro-6-8kw-inverter-charger-48v-120-240v/?ref=4_rHcgZ9x-TiF-
Schneider PDP, Large: signaturesolar.com/schneider-xw-power-distribution-panel-1-pole-250a-no-ac-breaker/?ref=4_rHcgZ9x-TiF-
Schneider PDP, Small: signaturesolar.com/schneider-xw-power-distribution-panel-mini-pdp/?ref=4_rHcgZ9x-TiF-
Schneider kit with inverters, PDP, and charge controllers: signaturesolar.com/bndl-dc-coupling-with-dual-inverter?ref=4_rHcgZ9x-TiF-
Complete Off grid kit: signaturesolar.com/complete-hybrid-solar-kit-schneider-dual-xw-pro-13-6kw-120-240v-output-30-72kwh-eg4-ll-v2-battery-powerwall-12710-watts-of-solar/?ref=4_rHcgZ9x-TiF-
Battery, 30.72 kWh, LiFePO4, EG4-LL, with cabinet and busbars: signaturesolar.com/eg4-ll-lithium-batteries-kit-48v-100ah-x-6-30-72kwh-6-server-rack-batteries-with-pre-assembled-enclosed-rack-with-door-wheelsac/?ref=4_rHcgZ9x-TiF-
Schneider Bundle with Mini-PDP: signaturesolar.com/bndl-dc-coupling-with-single-inverter?ref=4_rHcgZ9x-TiF-
---------------------------------------------------------------------------
Amazon Affiliate Links:
SPD, Surge Protection Device: amzn.to/3U9YBWW
4/0 Lugs, UL: amzn.to/3SGwP3q
Wire Cutters: amzn.to/3sD0BLU
Wire Crimpers, Hydraulic: amzn.to/3gUUZtS
Service Entrance Connector: amzn.to/3FrNPXZ
Zip Ties, UL: amzn.to/3DF1ARX
Cable Tie Tool: amzn.to/3sIRXvs
Torque Screwdriver: amzn.to/3DS8nYR
Driver Bits for Electrical Terminals: amzn.to/3DIWS5L
“As an Amazon Associate I earn from qualifying purchases.”
---------------------------------------------------------------------------
Disclaimer:
Products in video may have been provided to David Poz, LLC at no cost for the purpose of the review. All views and opinions expressed are that of David Poz, LLC.
My videos are in no way intended to be instructional "how-to" lessons. I am simply documenting my project for informational purposes. Property damage, personal injury, or death may result, even when following manufacturer's instructions. I cannot be held liable for such damage or injury. It is YOUR OBLIGATION to ensure that you are complying with any local and federal laws as well as code and permit requirements.
David Poz, LLC
This is a first impression video, please stay tuned for extensive testing to follow in future videos.
Signature Solar Affiliate Links:
Schneider XW PRO inverter: signaturesolar.com/schneider-conext-xw-pro-6-8kw-inverter-charger-48v-120-240v/?ref=4_rHcgZ9x-TiF-
Schneider kit with inverters, PDP, and charge controllers: signaturesolar.com/bndl-dc-coupling-with-dual-inverter?ref=4_rHcgZ9x-TiF-
Complete Off grid kit: signaturesolar.com/complete-hybrid-solar-kit-schneider-dual-xw-pro-13-6kw-120-240v-output-30-72kwh-eg4-ll-v2-battery-powerwall-12710-watts-of-solar/?ref=4_rHcgZ9x-TiF-
Battery, 30.72 kWh, LiFePO4, EG4-LL, with cabinet and busbars: signaturesolar.com/eg4-ll-lithium-batteries-kit-48v-100ah-x-6-30-72kwh-6-server-rack-batteries-with-pre-assembled-enclosed-rack-with-door-wheelsac/?ref=4_rHcgZ9x-TiF-
---------------------------------------------------------------------------
Disclaimer:
Products in video may have been provided to David Poz, LLC at no cost for the purpose of the review. All views and opinions expressed are that of David Poz, LLC.
My videos are in no way intended to be instructional "how-to" lessons. I am simply documenting my project for informational purposes. Property damage, personal injury, or death may result, even when following manufacturer's instructions. I cannot be held liable for such damage or injury. It is YOUR OBLIGATION to ensure that you are complying with any local and federal laws as well as code and permit requirements.
David Poz, LLC
My goal in this video is to have a step by step guide to help walk you through the process of setting up a large battery bank for your whole house backup. I use this off grid for my 100% electric house.
Signature Solar Affiliate Links:
30+kWh kit with batteries and rack: signaturesolar.com/eg4-lifepower4-lithium-batteries-kit-48v-100ah-x-6-30-72kwh-6-server-rack-batteries-with-pre-assembled-rack/?ref=4_rHcgZ9x-TiF-
New EG4 Battery with latest firmware and rack: signaturesolar.com/eg4-ll-lithium-batteries-kit-48v-100ah-x-6-30-72kwh-6-server-rack-batteries-with-pre-assembled-enclosed-rack-with-door-wheelsac/?ref=4_rHcgZ9x-TiF-
Wall Charger for LiFePO4 Batteris: signaturesolar.com/eg4-battery-charger-48v-18a-1/?ref=4_rHcgZ9x-TiF-
Read/write cable: signaturesolar.com/eg4-lifepower4-read-write-cable/?ref=4_rHcgZ9x-TiF-
48V 100Ah Battery page with manual and software downloads: signaturesolar.com/eg4-lifepower4-lithium-battery-48v-100ah/?ref=4_rHcgZ9x-TiF-
-------------------------------------------------------------------------------------------
Related Video:
Signature Solar firmware update video: youtu.be/ud-Z5im66vQ
-------------------------------------------------------------------------------------------
Amazon Affiliate Links:
Marking Pen: amzn.to/3ytqC3v
Auto Center Punch: amzn.to/3fUTBXG
Rivnut tool (updated): amzn.to/3RO4sQr
Blue Sea Fuse Holder for Class-T: amzn.to/3Eqt92c
Class-T fuse, 400A: amzn.to/3CmSYNQ
Thread Checker: amzn.to/3T4O5jp
Heat Shrink Tubing, 1.5": amzn.to/3CiDZEW
Bolt, serrated flange head, stainless steel: amzn.to/3T5go0Z
“As an Amazon Associate I earn from qualifying purchases.”
Ebay affiliate Link:
Copper Bar, 1x1/4": ebay.us/sTGHvg
-----------------------------------------------------
Disclaimer:
My videos are in no way intended to be instructional "how-to" lessons. I am simply documenting my project for informational purposes. Property damage, personal injury, or death may result, even when following manufacturer's instructions. I cannot be held liable for such damage or injury. It is YOUR OBLIGATION to ensure that you are complying with any local and federal laws as well as code and permit requirements.
David Poz, LLC
------------------------------------------------------------------------------------
Amazon Affiliate Links:
Busbar: amzn.to/3DviQJS
300W Inverter: amzn.to/3DwAOeW
Midnite Classic Solar Charge Controller, MPPT: amzn.to/3BVgClX
Midnite Combiner Box: amzn.to/3eSTprh
“As an Amazon Associate I earn from qualifying purchases.”
-------------------------------------------------------------------------------------
Disclaimer:
My videos are in no way intended to be instructional "how-to" lessons. I am simply documenting my project for informational purposes. Property damage, personal injury, or death may result, even when following manufacturer's instructions. I cannot be held liable for such damage or injury. It is YOUR OBLIGATION to ensure that you are complying with any local and federal laws as well as code and permit requirements.
David Poz, LLC
LifePower4 battery from Signature Solar is my favorite for building up a large scale system. This is for people wanting to back-up their whole house, or go off grid completely. Combine 2 or more batteries inside the enclosed cabinet for a perfect setup. The 48V batteries from Signature Solar come in 2 versions, with or without a screen. I don't think the screen version is worth the extra cost if you plan to use a central shunt anyways.
---------------------------------------------------
Signature Solar Affiliate Links:
LifePower4 battery without a screen: signaturesolar.com/eg4-lifepower4-lithium-battery-48v-100ah/?ref=4_rHcgZ9x-TiF-
EG4 battery with a screen: signaturesolar.com/eg4-ll-lithium-battery-48v-100ahd/?ref=4_rHcgZ9x-TiF-
Server Rack cabinet with locking door, and copper busbars: signaturesolar.com/pre-assembled-eg4-enclosed-battery-rack-6-slot-wheels-included/?ref=4_rHcgZ9x-TiF-
NEW! EG4 6kW inverter with transformer built in: signaturesolar.com/eg4-6k-off-grid-inverter-6000ex-48hv/?ref=4_rHcgZ9x-TiF-
Growatt 5000ES inverter, I use a pair to run my house: signaturesolar.com/growatt-5kw-stackable-off-grid-inverter-spf-5000-es/?ref=4_rHcgZ9x-TiF-
Battery Charger, CC/CV charger built for LiFePO4: signaturesolar.com/eg4-battery-charger-48v-18a-1/?ref=4_rHcgZ9x-TiF-
-------------------------------------------------------
Orient Power Affiliate Links:
5% Discount code: DAVIDPOZ
Powerwall battery is the newest version and hangs on the wall if you don't have a lot of floor space. The specs are the same as the server rack design, but in a vertical package: opsolarbattery.com/product-page/2-x-powerwall-48100pw?ref=dave_poz
Orient Power Main Page: opsolarbattery.com/shop?ref=dave_poz
Jakiper PRO Battery: opsolarbattery.com/product-page/jk48v100pro-server-rack-lifepo4-battery?ref=dave_poz
Rack with 4 batteries: Get a deal when buying the set of 4 with a steel rack: opsolarbattery.com/product-page/20kwbattery?ref=dave_poz
4 AWG (4 gauge) wires for connecting your batteries together: opsolarbattery.com/product-page/4-0-awg-red-black-flexible-battery-parallel-cables?ref=dave_poz
Rack alone: opsolarbattery.com/product-page/server-rack-battery-rack?ref=dave_poz
CC/CV charger for battery. (constant current, constant voltage)
opsolarbattery.com/product-page/battery-charger-57-6v-10a?ref=dave_poz
---------------------------------------------------------
Amazon Affiliate Links:
Pike Industries 400A Busbar Red: amzn.to/3JN7NN7
Pike Industries 400A Busbar Black: amzn.to/3zLuSv2
“As an Amazon Associate I earn from qualifying purchases.”
-------------------------------------------------------
Videos:
Part 1: testing a single Jakiper battery. youtu.be/uhoaIVkfkkQ
Part 2: testing the full rack of Jakiper batteries: youtu.be/vUsHznMa76U
Busbar comparison: youtu.be/vziEq_3OlcU
Building the Watt meter: youtu.be/sJ-sy8Osqr0
Disclaimer:
My videos are in no way intended to be instructional "how-to" lessons. I am simply documenting my project for informational purposes. Property damage, personal injury, or death may result, even when following manufacturer's instructions. I cannot be held liable for such damage or injury. It is YOUR OBLIGATION to ensure that you are complying with any local and federal laws as well as code and permit requirements.
David Poz, LLC
The cell chemistry is LiFePO4 (Lithium Iron Phosphate) which is the leading chemistry for home storage. Each battery works with 48V equipment but is technically 51.2V nominal, 100Ah. This means you have 5.12kWh of capacity.
I run through a series of tests and was happy with it's outcome. Yes, I was able to overload and shut down the battery, but that was pushing it past it's 100A rating. When staying below 100A, the battery worked as advertised.
This is an excellent choice for small off grid solar systems where you don't need a full rack of batteries taking up floor space. Mounting a few of these on the wall will likely make for a cleaner installation on small off grid builds
5% Discount code: DAVIDPOZ
Powerwall battery is the newest version and hangs on the wall if you don't have a lot of floor space. The specs are the same as the server rack design, but in a vertical package: opsolarbattery.com/product-page/2-x-powerwall-48100pw?ref=dave_poz
Orient Power Main Page: opsolarbattery.com/shop?ref=dave_poz
Jakiper PRO Battery: opsolarbattery.com/product-page/jk48v100pro-server-rack-lifepo4-battery?ref=dave_poz
Rack with 4 batteries: Get a deal when buying the set of 4 with a steel rack: opsolarbattery.com/product-page/20kwbattery?ref=dave_poz
4 AWG (4 gauge) wires for connecting your batteries together: opsolarbattery.com/product-page/4-0-awg-red-black-flexible-battery-parallel-cables?ref=dave_poz
Rack alone: opsolarbattery.com/product-page/server-rack-battery-rack?ref=dave_poz
CC/CV charger for battery. (constant current, constant voltage)
opsolarbattery.com/product-page/battery-charger-57-6v-10a?ref=dave_poz
Amazon Affiliate Links:
Pike Industries 400A Busbar Red: amzn.to/3JN7NN7
Pike Industries 400A Busbar Black: amzn.to/3zLuSv2
“As an Amazon Associate I earn from qualifying purchases.”
Videos:
Part 1: testing a single Jakiper battery. youtu.be/uhoaIVkfkkQ
Part 2: testing the full rack of Jakiper batteries: youtu.be/vUsHznMa76U
Busbar comparison: youtu.be/vziEq_3OlcU
Building the Watt meter: youtu.be/sJ-sy8Osqr0
Disclaimer:
My videos are in no way intended to be instructional "how-to" lessons. I am simply documenting my project for informational purposes. Property damage, personal injury, or death may result, even when following manufacturer's instructions. I cannot be held liable for such damage or injury. It is YOUR OBLIGATION to ensure that you are complying with any local and federal laws as well as code and permit requirements.
David Poz, LLC
In part 2 we wired the rack of Jakiper batteries as a "daisy chain". We saw the wires were getting too hot in that setup. Now we re-wire the rack to a central busbar and re-run the load test. WOW! The results are amazing.
5% Discount code: DAVIDPOZ
Jakiper (Orient Power) sent me some of the new "PRO" batteries for testing and review. This is Part 3 in the video series.
This battery is part of the Jakiper line. Model# JK48V100PRO Server Rack design. The cell chemistry is LiFePO4 (Lithium Iron Phosphate) which is the leading chemistry for home storage. Each battery works with 48V equipment but is technically 51.2V nominal, 100Ah. This means you have 5.12kWh of capacity.
There are 4 batteries in the rack. This makes a total of 20.48 kWh.
Affiliate Links:
300 Amp Class-T Fuse and Fuse Holder: ebay.us/WGCX1c
HDPE Sheets: ebay.us/2Wh8qZ
Use coupon code DAVIDPOZ for a discount on your order.
Orient Power Main Page: opsolarbattery.com/shop?ref=dave_poz
Jakiper PRO Battery: opsolarbattery.com/product-page/jk48v100pro-server-rack-lifepo4-battery?ref=dave_poz
Rack with 4 batteries: Get a deal when buying the set of 4 with a steel rack: opsolarbattery.com/product-page/20kwbattery?ref=dave_poz
Powerwall battery is the newest version and hangs on the wall if you don't have a lot of floor space. The specs are the same as the server rack design, but in a vertical package: opsolarbattery.com/product-page/2-x-powerwall-48100pw?ref=dave_poz
4 AWG (4 gauge) wires for connecting your batteries together: opsolarbattery.com/product-page/4-0-awg-red-black-flexible-battery-parallel-cables?ref=dave_poz
Rack alone: opsolarbattery.com/product-page/server-rack-battery-rack?ref=dave_poz
CC/CV charger for battery. (constant current, constant voltage)
opsolarbattery.com/product-page/battery-charger-57-6v-10a?ref=dave_poz
Amazon Affiliate Links:
Pike Industries 400A Busbar Red: amzn.to/3JN7NN7
Pike Industries 400A Busbar Black: amzn.to/3zLuSv2
“As an Amazon Associate I earn from qualifying purchases.”
Videos:
Part 1: testing a single Jakiper battery. youtu.be/uhoaIVkfkkQ
Part 2: testing the full rack of Jakiper batteries: youtu.be/vUsHznMa76U
Busbar comparison: youtu.be/vziEq_3OlcU
Building the Watt meter: youtu.be/sJ-sy8Osqr0
Disclaimer:
My videos are in no way intended to be instructional "how-to" lessons. I am simply documenting my project for informational purposes. Property damage, personal injury, or death may result, even when following manufacturer's instructions. I cannot be held liable for such damage or injury. It is YOUR OBLIGATION to ensure that you are complying with any local and federal laws as well as code and permit requirements.
David Poz, LLC
I'll be using this buss bar in a stack of batteries in a future video. The stack of batteries has a 400 Amp continuous rating. I need a buss bar that can handle that without getting hot.
Videos:
Jakiper Part 2, Server Rack style 48V LiFePo4 battery bank: youtu.be/vUsHznMa76U
Amazon Affiliate Links:
Pike Industries 400A Busbar Red: amzn.to/3JN7NN7
Pike Industries 400A Busbar Black: amzn.to/3zLuSv2
Cheap Busbar kit (red and black): amzn.to/3zKwDIZ
“As an Amazon Associate I earn from qualifying purchases.”
Disclaimer:
My videos are in no way intended to be instructional "how-to" lessons. I am simply documenting my project for informational purposes. Property damage, personal injury, or death may result, even when following manufacturer's instructions. I cannot be held liable for such damage or injury. It is YOUR OBLIGATION to ensure that you are complying with any local and federal laws as well as code and permit requirements.
David Poz, LLC
Jakiper (Orient Power) sent me some of the new "PRO" batteries for testing and review. This is Part 2 in the video series.
This battery is part of the Jakiper line. Model# JK48V100PRO Server Rack design. The cell chemistry is LiFePO4 (Lithium Iron Phosphate) which is the leading chemistry for home storage. Each battery works with 48V equipment but is technically 51.2V nominal, 100Ah. This means you have 5.12kWh of capacity.
There are 4 batteries in the rack. This makes a total of 20.48 kWh.
Affiliate Links:
Use coupon code DAVIDPOZ for a discount on your order.
Orient Power Main Page: opsolarbattery.com/shop?ref=dave_poz
Jakiper PRO Battery: opsolarbattery.com/product-page/jk48v100pro-server-rack-lifepo4-battery?ref=dave_poz
Rack with 4 batteries: Get a deal when buying the set of 4 with a steel rack: opsolarbattery.com/product-page/20kwbattery?ref=dave_poz
Powerwall battery is the newest version and hangs on the wall if you don't have a lot of floor space. The specs are the same as the server rack design, but in a vertical package: opsolarbattery.com/product-page/2-x-powerwall-48100pw?ref=dave_poz
4 AWG (4 gauge) wires for connecting your batteries together: opsolarbattery.com/product-page/4-0-awg-red-black-flexible-battery-parallel-cables?ref=dave_poz
Rack alone: opsolarbattery.com/product-page/server-rack-battery-rack?ref=dave_poz
CC/CV charger for battery. (constant current, constant voltage)
opsolarbattery.com/product-page/battery-charger-57-6v-10a?ref=dave_poz
Videos:
Part 1: testing a single Jakiper Battery. youtu.be/uhoaIVkfkkQ
Building the Watt meter: youtu.be/sJ-sy8Osqr0
Disclaimer:
My videos are in no way intended to be instructional "how-to" lessons. I am simply documenting my project for informational purposes. Property damage, personal injury, or death may result, even when following manufacturer's instructions. I cannot be held liable for such damage or injury. It is YOUR OBLIGATION to ensure that you are complying with any local and federal laws as well as code and permit requirements.
David Poz, LLC
Jakiper (Orient Power) sent me some of the new "PRO" batteries for testing and review. I spent 1 week putting it through some crazy paces to see where it fails, and where it holds up. This is Part 1 of testing this battery.
This battery is part of the Jakiper line. Model# JK48V100PRO Server Rack design. The cell chemistry is LiFePO4 (Lithium Iron Phosphate) which is the leading chemistry for home storage. Each battery works with 48V equipment but is technically 51.2V nominal, 100Ah. This means you have 5.12kWh of capacity.
There are 4 capacity tests, a freezer test, and load test.
Affiliate Links:
Use coupon code DAVIDPOZ for a discount on your order.
Orient Power Main Page: opsolarbattery.com/shop?ref=dave_poz
Jakiper PRO Battery: opsolarbattery.com/product-page/jk48v100pro-server-rack-lifepo4-battery?ref=dave_poz
Rack with 4 batteries: Get a deal when buying the set of 4 with a steel rack: opsolarbattery.com/product-page/20kwbattery?ref=dave_poz
Powerwall battery is the newest version and hangs on the wall if you don't have a lot of floor space. The specs are the same as the server rack design, but in a vertical package: opsolarbattery.com/product-page/2-x-powerwall-48100pw?ref=dave_poz
4 AWG (4 gauge) wires for connecting your batteries together: opsolarbattery.com/product-page/4-0-awg-red-black-flexible-battery-parallel-cables?ref=dave_poz
Rack alone: opsolarbattery.com/product-page/server-rack-battery-rack?ref=dave_poz
CC/CV charger for battery. (constant current, constant voltage)
opsolarbattery.com/product-page/battery-charger-57-6v-10a?ref=dave_poz
Correction, there is no free shipping.
Videos:
Building the Watt meter: youtu.be/sJ-sy8Osqr0
Disclaimer:
My videos are in no way intended to be instructional "how-to" lessons. I am simply documenting my project for informational purposes. Property damage, personal injury, or death may result, even when following manufacturer's instructions. I cannot be held liable for such damage or injury. It is YOUR OBLIGATION to ensure that you are complying with any local and federal laws as well as code and permit requirements.
David Poz, LLC
Victron vs. Growatt solar MPPT charge controller efficiency test
I'm testing the Growatt SPF 5000ES inverter which has a built-in charge controller. The Victron is model 250/100. The Growatt inverter is an all-in-one unit with both a charge controller and inverter. These all-in-one units really do well when you use the power as it's being created.
I'm taking all measurements using my multi-meter so the results will be consistent between the two products.
Note: The Victron MPPT charge controller has a maximum input of 250V and the Growatt MPPT charge controller has a maximum input of 450V. This means you can (usually) save money with the higher voltage by not needing a combiner box and circuit breakers.
Affiliate Links (Signature Solar):
Growatt Inverters, 5000ES: signaturesolar.com/growatt-48v-5kw-450vdc-stackable-off-grid-inverter/?ref=4_rHcgZ9x-TiF-#
EG4-LifePower4 48V 100Ah Battery: signaturesolar.com/eg4-lifepower4-lithium-battery-48v-100ah/?ref=4_rHcgZ9x-TiF-
EG4 LiFePO4 5120Wh with display: signaturesolar.com/eg4-ll-lithium-battery-48v-100ah/?ref=4_rHcgZ9x-TiF-
Circuit Breaker: signaturesolar.com/nadar-dc-circuit-breaker-48v-125-amp/?ref=4_rHcgZ9x-TiF-
Amazon Affiliate Links:
Victron Charge Controller: amzn.to/3IIDiY9
Multi-meter (exact model in video is no longer available: amzn.to/3aF1u0X
Videos:
Building powerwall with 1 inverter: youtu.be/oMH3IwR0ZC8
First Battery Review: youtu.be/SYJ25izYSGc
Building Battery Bank over 30 kWh: youtu.be/89MyA7zPdYI
Growatt 5000ES inverter with auto transformer: youtu.be/yWUfvvSa3K8
Disclaimer:
My videos are in no way intended to be instructional "how-to" lessons. I am simply documenting my project for informational purposes. Property damage, personal injury, or death may result, even when following manufacturer's instructions. I cannot be held liable for such damage or injury. It is YOUR OBLIGATION to ensure that you are complying with any local and federal laws as well as code and permit requirements.
David Poz, LLC
I've been running my Growatt inverters and Lithium batteries off grid for one year. They have been working great. In the video I describe pros and cons after one year of use.
The inverters are model 5000ES and purchased from Signature Solar. I have two in parallel for a total of 10kW of inverting capacity.
The batteries are Lithium, LiFePO4. Each battery is 5.12kWh of capacity in a server rack design. This mean my battery bank is just over 30kWh! My battery brand is Gyll, but that has been re-branded EG4 and is sold by Signature Solar.
Affiliate Links (Signature Solar):
Growatt Inverters, 5000ES: signaturesolar.com/growatt-48v-5kw-450vdc-stackable-off-grid-inverter/?ref=4_rHcgZ9x-TiF-#
EG4-LifePower4 48V 100Ah Battery: signaturesolar.com/eg4-lifepower4-lithium-battery-48v-100ah/?ref=4_rHcgZ9x-TiF-
EG4 LiFePO4 5120Wh with display: signaturesolar.com/eg4-ll-lithium-battery-48v-100ah/?ref=4_rHcgZ9x-TiF-
Circuit Breaker: signaturesolar.com/nadar-dc-circuit-breaker-48v-125-amp/?ref=4_rHcgZ9x-TiF-
Videos:
Building powerwall with 1 inverter: youtu.be/oMH3IwR0ZC8
First Battery Review: youtu.be/SYJ25izYSGc
Building Battery Bank over 30 kWh: youtu.be/89MyA7zPdYI
Growatt 5000ES inverter with auto transformer: youtu.be/yWUfvvSa3K8
Disclaimer:
My videos are in no way intended to be instructional "how-to" lessons. I am simply documenting my project for informational purposes. Property damage, personal injury, or death may result, even when following manufacturer's instructions. I cannot be held liable for such damage or injury. It is YOUR OBLIGATION to ensure that you are complying with any local and federal laws as well as code and permit requirements.
David Poz, LLC
This is a 2003 Club Car Golf Cart that came with a 48V lead acid battery. We are swapping out the old lead acid batteries for a new 48V (51.2V) Lithium. The battery is a 100 Ah, 5.12kWh, LiFePO4, sold by Signature Solar under the brand EG4. The type we are using is waterproof.
Video Review of EG4 Battery: youtu.be/L2fB4ZwkWrQ
Affiliate Links:
Battery, Waterproof EG4: 48V LiFePO4 Lithium Battery with Bluetooth, EG4 Brand: https://signaturesolar.com/eg4-wp-lit...
Charger, 48V, LiFePO4, Waterproof: signaturesolar.com/eg4-battery-charger-48v-18a-1/?ref=4_rHcgZ9x-TiF-
Growatt 5000W Inverter with 450V MPPT Charge Controller 5000ES: https://signaturesolar.com/growatt-48...
Auto-Transformer, 5000ES: https://signaturesolar.com/growatt-5k...
EG4 Battery, 48V, 100Ah, 5.12kWh, LiFePO4, Server Rack design: https://signaturesolar.com/shop-all/b...
Amazon Affiliate Links:
Hydraulic Crimper: amzn.to/39kZqul
Ring Terminals, UL, Marine: amzn.to/3toDDc0
Power Port, Panel mount: amzn.to/3MGdHzG
48V to 12V Buck Converter: amzn.to/3NAyHch
“As an Amazon Associate I earn from qualifying purchases.”
Disclaimer:
My videos are in no way intended to be instructional "how-to" lessons. I am simply documenting my project for informational purposes. Property damage, personal injury, or death may result, even when following manufacturer's instructions. I cannot be held liable for such damage or injury. It is YOUR OBLIGATION to ensure that you are complying with any local and federal laws as well as code and permit requirements.
David Poz, LLC
Kevin's website: https://www.intelligent.solar/
My personal DIY system uses these parts:
Affiliate Links:
Growatt 5000W Inverter with 450V MPPT Charge Controller 5000ES: signaturesolar.com/growatt-48v-5kw-450vdc-stackable-off-grid-inverter/?ref=4_rHcgZ9x-TiF-
Auto-Transformer, 5000ES: signaturesolar.com/growatt-5kw-split-phase-transformer/?ref=4_rHcgZ9x-TiF-
EG4 Battery, 48V, 100Ah, 5.12kWh, LiFePO4, Server Rack design: signaturesolar.com/shop-all/batteries/?ref=4_rHcgZ9x-TiF-
Waterproof EG4 battery: 48V LiFePO4 Lithium Battery with Bluetooth, EG4 Brand: signaturesolar.com/eg4-wp-lithium-battery-48v-100ah?ref=4_rHcgZ9x-TiF-
Disclaimer:
My videos are in no way intended to be instructional "how-to" lessons. I am simply documenting my project for informational purposes. Property damage, personal injury, or death may result, even when following manufacturer's instructions. I cannot be held liable for such damage or injury. It is YOUR OBLIGATION to ensure that you are complying with any local and federal laws as well as code and permit requirements.
David Poz, LLC
Affiliate Links:
Growatt 5000W Inverter with 450V MPPT Charge Controller 5000ES: signaturesolar.com/growatt-48v-5kw-450vdc-stackable-off-grid-inverter/?ref=4_rHcgZ9x-TiF-
Auto-Transformer, 5000ES: signaturesolar.com/growatt-5kw-split-phase-transformer/?ref=4_rHcgZ9x-TiF-
EG4 Battery, 48V, 100Ah, 5.12kWh, LiFePO4, Server Rack design: signaturesolar.com/shop-all/batteries/?ref=4_rHcgZ9x-TiF-
Waterproof EG4 battery: 48V LiFePO4 Lithium Battery with Bluetooth, EG4 Brand: signaturesolar.com/eg4-wp-lithium-battery-48v-100ah?ref=4_rHcgZ9x-TiF-
Disclaimer:
My videos are in no way intended to be instructional "how-to" lessons. I am simply documenting my project for informational purposes. Property damage, personal injury, or death may result, even when following manufacturer's instructions. I cannot be held liable for such damage or injury. It is YOUR OBLIGATION to ensure that you are complying with any local and federal laws as well as code and permit requirements.
David Poz, LLC
Part 1, Building the Powerall: youtu.be/oMH3IwR0ZC8
Part 2, Initial setup and testing: youtu.be/nKva5GsEPXc
Affiliate Links:
Growatt 5000W Inverter with 450V MPPT Charge Controller 5000ES: signaturesolar.com/growatt-48v-5kw-450vdc-stackable-off-grid-inverter/?ref=4_rHcgZ9x-TiF-
Auto-Transformer, 5000ES: signaturesolar.com/growatt-5kw-split-phase-transformer/?ref=4_rHcgZ9x-TiF-
EG4 Battery, 48V, 100Ah, 5.12kWh, LiFePO4, Server Rack design: signaturesolar.com/shop-all/batteries/?ref=4_rHcgZ9x-TiF-
Waterproof EG4 battery: 48V LiFePO4 Lithium Battery with Bluetooth, EG4 Brand: signaturesolar.com/eg4-wp-lithium-battery-48v-100ah?ref=4_rHcgZ9x-TiF-
Disclaimer:
My videos are in no way intended to be instructional "how-to" lessons. I am simply documenting my project for informational purposes. Property damage, personal injury, or death may result, even when following manufacturer's instructions. I cannot be held liable for such damage or injury. It is YOUR OBLIGATION to ensure that you are complying with any local and federal laws as well as code and permit requirements.
David Poz, LLC
I have two inverters running in parallel. They are Growatt SPF 5000 ES purchased from Signature Solar. Each inverter is 5kW, so combined that's 10kW of power. I've combined it with 30kWh of battery capacity. The batteries I'm using are Gyll (EG4) 48V LiFePO4. This is all part of my off grid solar system running my whole house and garage.
The inverter makes 240VAC single phase. I'm using the auto-transformer from solar-edge to create a neutral. This "splits" the 240V in half, providing me two 120V legs.
Keep in mind, this is a DIY channel. I'm using my equipment off grid. Please be safe for your own setups. Filming and editing this video took place over the course of 2 weeks.
Video Links:
Using the auto-transformer: youtu.be/yWUfvvSa3K8
Making a Powerwall with one inverter: youtu.be/oMH3IwR0ZC8
Affiliate Links:
Growatt 5000W Inverter with 450V MPPT Charge Controller 5000ES: signaturesolar.com/growatt-48v-5kw-450vdc-stackable-off-grid-inverter/?ref=4_rHcgZ9x-TiF-
Auto-Transformer, 5000ES: signaturesolar.com/growatt-5kw-split-phase-transformer/?ref=4_rHcgZ9x-TiF-
EG4 Battery, 48V, 100Ah, 5.12kWh, LiFePO4, Server Rack design: signaturesolar.com/shop-all/batteries/?ref=4_rHcgZ9x-TiF-
Waterproof EG4 battery: 48V LiFePO4 Lithium Battery with Bluetooth, EG4 Brand: signaturesolar.com/eg4-wp-lithium-battery-48v-100ah?ref=4_rHcgZ9x-TiF-
Amazon Affiliate Links:
3- pole circuit breaker: amzn.to/3r9mWkh
“As an Amazon Associate I earn from qualifying purchases.”
Disclaimer:
My videos are in no way intended to be instructional "how-to" lessons. I am simply documenting my project for informational purposes. Property damage, personal injury, or death may result, even when following manufacturer's instructions. I cannot be held liable for such damage or injury. It is YOUR OBLIGATION to ensure that you are complying with any local and federal laws as well as code and permit requirements.
David Poz, LLC
Original Install Video: youtu.be/Kd092alkeaE
Signature Solar affiliate Links:
Heat Pump: signaturesolar.com/innovair-mini-split-ac-heat-pump-9000-btu/?ref=4_rHcgZ9x-TiF-
Affiliate Links:
Growatt 5000W Inverter with 450V MPPT Charge Controller 5000ES: signaturesolar.com/growatt-48v-5kw-450vdc-stackable-off-grid-inverter/?ref=4_rHcgZ9x-TiF-
Auto-Transformer, 5000ES: signaturesolar.com/growatt-5kw-split-phase-transformer/?ref=4_rHcgZ9x-TiF-
EG4 Battery, 48V, 100Ah, 5.12kWh, LiFePO4, Server Rack design: signaturesolar.com/shop-all/batteries/?ref=4_rHcgZ9x-TiF-
Waterproof EG4 battery: 48V LiFePO4 Lithium Battery with Bluetooth, EG4 Brand: signaturesolar.com/eg4-wp-lithium-battery-48v-100ah?ref=4_rHcgZ9x-TiF-
The mini-split heat pump is a 9000 BTU model from Innovair. It does both heating and cooling. It touts an amazing claim of 38 SEER! Signature Solar provided this unit at no cost for the original video. I've chosen to make this follow up video to answer the questions from the viewers. The thoughts and opinions expressed in this video are mine alone. Thanks for watching, David.
Amazon affiliate links:
Watt Meter: amzn.to/3KckkcL
Vacuum pump and gauge set: amzn.to/3jAG9WO
Flare Tool eccentric cone: amzn.to/3CsnBRx
Nylog sealant: amzn.to/3CpzBD4
Lineset cover: amzn.to/2WVNloU
Deburring Tool: amzn.to/3AnFrmy
“As an Amazon Associate I earn from qualifying purchases.”
Disclaimer:
My videos are in no way intended to be instructional "how-to" lessons. I am simply documenting my project for informational purposes. Property damage, personal injury, or death may result, even when following manufacturer's instructions. I cannot be held liable for such damage or injury. It is YOUR OBLIGATION to ensure that you are complying with any local and federal laws as well as code and permit requirements.
David Poz, LLC
Video Building a Powerwall: youtu.be/oMH3IwR0ZC8
Video setting up Powerwall at my friends home: youtu.be/nKva5GsEPXc
Amazon Affiliate Links:
125A DC circuit breaker, 2-pole: amzn.to/3q7IYDe
125A DC circuit breaker, 1-pole: amzn.to/3G6MK5D
100A DC circuit breaker, 3-pole: amzn.to/3G6KFqp
Din-Rail Box: amzn.to/3zDKoZG
Midnite Solar Bus Bars: amzn.to/3HKgB4d
Bus Bars: amzn.to/3HLp2fG
Resistors to pre-charge inverters: amzn.to/3zyXHKN
“As an Amazon Associate I earn from qualifying purchases.”
Affiliate Links:
Growatt 5000W Inverter with 450V MPPT Charge Controller 5000ES: signaturesolar.com/growatt-48v-5kw-450vdc-stackable-off-grid-inverter/?ref=4_rHcgZ9x-TiF-
Auto-Transformer, 5000ES: signaturesolar.com/growatt-5kw-split-phase-transformer/?ref=4_rHcgZ9x-TiF-
EG4 Battery, 48V, 100Ah, 5.12kWh, LiFePO4, Server Rack design: signaturesolar.com/shop-all/batteries/?ref=4_rHcgZ9x-TiF-
Waterproof EG4 battery: 48V LiFePO4 Lithium Battery with Bluetooth, EG4 Brand: signaturesolar.com/eg4-wp-lithium-battery-48v-100ah?ref=4_rHcgZ9x-TiF-
Disclaimer:
My videos are in no way intended to be instructional "how-to" lessons. I am simply documenting my project for informational purposes. Property damage, personal injury, or death may result, even when following manufacturer's instructions. I cannot be held liable for such damage or injury. It is YOUR OBLIGATION to ensure that you are complying with any local and federal laws as well as code and permit requirements.
David Poz, LLC
Photos: I'd like to thank 3 people for helping me with RV photos. Thank you to Mark, Mark, and (anonymous), for your help.
The answer is to use a transformer. I bought a used one for $50. Check around locally on Craigslist, Ebay, and Facebook Marketplace.
Mini-Split Heat Pump, 38 SEER: shop.signaturesolar.us/products/mini-split-ac-heat-pump-9000-btu-by-innovair?ref=4_rHcgZ9x-TiF-
(affiliate link to Signature Solar)
Amazon Affiliate Links:
Step-down Isolation Transformer: amzn.to/3JmwPlB
Wago wire connectors: amzn.to/3mANLv7
Plug-in 120V Watt Meter: amzn.to/3mxVA4I
Clamp, 240V Watt Meter: amzn.to/3mxVA4I
Bluetti AC240P: amzn.to/32ngdd1
“As an Amazon Associate I earn from qualifying purchases.”
Affiliate Links:
Growatt 5000W Inverter with 450V MPPT Charge Controller 5000ES: signaturesolar.com/growatt-48v-5kw-450vdc-stackable-off-grid-inverter/?ref=4_rHcgZ9x-TiF-
Auto-Transformer, 5000ES: signaturesolar.com/growatt-5kw-split-phase-transformer/?ref=4_rHcgZ9x-TiF-
EG4 Battery, 48V, 100Ah, 5.12kWh, LiFePO4, Server Rack design: signaturesolar.com/shop-all/batteries/?ref=4_rHcgZ9x-TiF-
Waterproof EG4 battery: 48V LiFePO4 Lithium Battery with Bluetooth, EG4 Brand: signaturesolar.com/eg4-wp-lithium-battery-48v-100ah?ref=4_rHcgZ9x-TiF-
Disclaimer:
My videos are in no way intended to be instructional "how-to" lessons. I am simply documenting my project for informational purposes. Property damage, personal injury, or death may result, even when following manufacturer's instructions. I cannot be held liable for such damage or injury. It is YOUR OBLIGATION to ensure that you are complying with any local and federal laws as well as code and permit requirements.
David Poz, LLC
First Video: youtu.be/Hz4vaWwUee8
Amazon Affiliate Links:
Victron Smart Shunt: amzn.to/3loxNUg
“As an Amazon Associate I earn from qualifying purchases.”
Affiliate Links:
Growatt 5000W Inverter with 450V MPPT Charge Controller 5000ES: signaturesolar.com/growatt-48v-5kw-450vdc-stackable-off-grid-inverter/?ref=4_rHcgZ9x-TiF-
Auto-Transformer, 5000ES: signaturesolar.com/growatt-5kw-split-phase-transformer/?ref=4_rHcgZ9x-TiF-
EG4 Battery, 48V, 100Ah, 5.12kWh, LiFePO4, Server Rack design: signaturesolar.com/shop-all/batteries/?ref=4_rHcgZ9x-TiF-
Waterproof EG4 battery: 48V LiFePO4 Lithium Battery with Bluetooth, EG4 Brand: signaturesolar.com/eg4-wp-lithium-battery-48v-100ah?ref=4_rHcgZ9x-TiF-
Disclaimer:
My videos are in no way intended to be instructional "how-to" lessons. I am simply documenting my project for informational purposes. Property damage, personal injury, or death may result, even when following manufacturer's instructions. I cannot be held liable for such damage or injury. It is YOUR OBLIGATION to ensure that you are complying with any local and federal laws as well as code and permit requirements.
David Poz, LLC
Is the Sol-Ark 12K Outdoor inverter really worth $7,000? It's such a premium price. Personally, I don't need all the features so I don't think it's worth it for me.
Amazon Affiliate Links:
Victron Smart Shunt: amzn.to/3loxNUg
“As an Amazon Associate I earn from qualifying purchases.”
Affiliate Links:
Growatt 5000W Inverter with 450V MPPT Charge Controller 5000ES: signaturesolar.com/growatt-48v-5kw-450vdc-stackable-off-grid-inverter/?ref=4_rHcgZ9x-TiF-
Auto-Transformer, 5000ES: signaturesolar.com/growatt-5kw-split-phase-transformer/?ref=4_rHcgZ9x-TiF-
EG4 Battery, 48V, 100Ah, 5.12kWh, LiFePO4, Server Rack design: signaturesolar.com/shop-all/batteries/?ref=4_rHcgZ9x-TiF-
Waterproof EG4 battery: 48V LiFePO4 Lithium Battery with Bluetooth, EG4 Brand: signaturesolar.com/eg4-wp-lithium-battery-48v-100ah?ref=4_rHcgZ9x-TiF-
Disclaimer:
My videos are in no way intended to be instructional "how-to" lessons. I am simply documenting my project for informational purposes. Property damage, personal injury, or death may result, even when following manufacturer's instructions. I cannot be held liable for such damage or injury. It is YOUR OBLIGATION to ensure that you are complying with any local and federal laws as well as code and permit requirements.
David Poz, LLC
Amazon Affiliate Link:
Wind Turbine kit: amzn.to/3nwf9uW
“As an Amazon Associate I earn from qualifying purchases.”
36V modules ship on pallets, so it makes more economic sense to buy more than one. Then the fixed cost of the pallet is distributed over more modules.
I'll be adding a BMS and heat shrink in future videos.
To buy go to Battery Hookup. Please use discount code DAVIDPOZ at checkout as it gets you a discount, and tracks the affiliate program to help this channel.
36V SPIM08 module: batteryhookup.com/products/36v-48ah-1776wh-spim08hp-36v-power-module
SPIM08HP cell pairs: batteryhookup.com/products/2x-spim08hp-3-7v-8ah-cells-with-threaded-insert
BMS for 36V: batteryhookup.com/collections/accessories/products/12v-lifepo4-smart-bms-w-low-temp-cutoff?variant=36287975260322 Select "10s Li-ion" from the drop down list.
Amazon Affiliate Links:
Thread Checker: amzn.to/3HuLTgj
“As an Amazon Associate I earn from qualifying purchases.”
Disclaimer:
My videos are in no way intended to be instructional "how-to" lessons. I am simply documenting my project for informational purposes. Property damage, personal injury, or death may result, even when following manufacturer's instructions. I cannot be held liable for such damage or injury. It is YOUR OBLIGATION to ensure that you are complying with any local and federal laws as well as code and permit requirements.
In this vide I give a DIY Off Grid Solar System (powerwall) to a friend of mine. He will be using it to power his tiny house on wheels (THOW) down in Florida. This will run his air conditioner and well pump.
We hung it on his wall using a French Cleat. Then drove a ground rod for safety. Finally, we connected some solar panels to it using MC4 cables.
Video Building the Powerwall: youtu.be/oMH3IwR0ZC8
Update: There is no longer a discount code available.
For Solar Panels in/around Massachusetts, contact Zach:
Zach@cedgreentecheast.com
774.243.9596
And tell him DAVID POZ sent you. (no affiliate, just for fun)
Amazon Affiliate Links:
Bosch Rotary Hammer Drill, SDS: amzn.to/3ER4yQZ
MC4 kit: amzn.to/30bktee
IMO PV disconnect switch: amzn.to/3bMrJQf
"As an Amazon Associate I earn from qualifying purchases."
Affiliate Links:
Growatt 5000W Inverter with 450V MPPT Charge Controller 5000ES: signaturesolar.com/growatt-48v-5kw-450vdc-stackable-off-grid-inverter/?ref=4_rHcgZ9x-TiF-
Auto-Transformer, 5000ES: signaturesolar.com/growatt-5kw-split-phase-transformer/?ref=4_rHcgZ9x-TiF-
EG4 Battery, 48V, 100Ah, 5.12kWh, LiFePO4, Server Rack design: signaturesolar.com/shop-all/batteries/?ref=4_rHcgZ9x-TiF-
Waterproof EG4 battery: 48V LiFePO4 Lithium Battery with Bluetooth, EG4 Brand: signaturesolar.com/eg4-wp-lithium-battery-48v-100ah?ref=4_rHcgZ9x-TiF-
Disclaimer:
My videos are in no way intended to be instructional "how-to" lessons. I am simply documenting my project for informational purposes. Property damage, personal injury, or death may result, even when following manufacturer's instructions. I cannot be held liable for such damage or injury. It is YOUR OBLIGATION to ensure that you are complying with any local and federal laws as well as code and permit requirements.
David Poz, LLC
This video is a installation, and first impressions. O, and don't buy a plastic transfer switch. This video is NOT a detailed test video. That will be coming soon. But please let my know in the comments what testing you would like to see this Sol-Ark go through.
Battery bank is a 30+kWh bank of LiFePO4 48V. I purchased the batteries from Signature Solar. There are two versions available, one with a screen and one without.
Update: There is no longer a discount code available.
Amazon Affiliate Links:
Power Distribution Block: amzn.to/30pyHrJ
3:1 Heat Shrink Tubing: amzn.to/3aFBCP9
2/0 Wire: amzn.to/3AOHG2h
2/0 Ring Terminals, UL: amzn.to/3vgQtZG
“As an Amazon Associate I earn from qualifying purchases.”
Affiliate Links:
Growatt 5000W Inverter with 450V MPPT Charge Controller 5000ES: signaturesolar.com/growatt-48v-5kw-450vdc-stackable-off-grid-inverter/?ref=4_rHcgZ9x-TiF-
Auto-Transformer, 5000ES: signaturesolar.com/growatt-5kw-split-phase-transformer/?ref=4_rHcgZ9x-TiF-
EG4 Battery, 48V, 100Ah, 5.12kWh, LiFePO4, Server Rack design: signaturesolar.com/shop-all/batteries/?ref=4_rHcgZ9x-TiF-
Waterproof EG4 battery: 48V LiFePO4 Lithium Battery with Bluetooth, EG4 Brand: signaturesolar.com/eg4-wp-lithium-battery-48v-100ah?ref=4_rHcgZ9x-TiF-
Disclaimer:
My videos are in no way intended to be instructional "how-to" lessons. I am simply documenting my project for informational purposes. Property damage, personal injury, or death may result, even when following manufacturer's instructions. I cannot be held liable for such damage or injury. It is YOUR OBLIGATION to ensure that you are complying with any local and federal laws as well as code and permit requirements.
David Poz, LLC
Update: There is no longer a discount code available.
Affiliate Links:
Growatt 5000W Inverter with 450V MPPT Charge Controller 5000ES: signaturesolar.com/growatt-48v-5kw-450vdc-stackable-off-grid-inverter/?ref=4_rHcgZ9x-TiF-
Auto-Transformer, 5000ES: signaturesolar.com/growatt-5kw-split-phase-transformer/?ref=4_rHcgZ9x-TiF-
EG4 Battery, 48V, 100Ah, 5.12kWh, LiFePO4, Server Rack design: signaturesolar.com/shop-all/batteries/?ref=4_rHcgZ9x-TiF-
Waterproof EG4 battery: 48V LiFePO4 Lithium Battery with Bluetooth, EG4 Brand: signaturesolar.com/eg4-wp-lithium-battery-48v-100ah?ref=4_rHcgZ9x-TiF-
Disclaimer:
My videos are in no way intended to be instructional "how-to" lessons. I am simply documenting my project for informational purposes. Property damage, personal injury, or death may result, even when following manufacturer's instructions. I cannot be held liable for such damage or injury. It is YOUR OBLIGATION to ensure that you are complying with any local and federal laws as well as code and permit requirements.
David Poz, LLC
My friend's nick-name is Poet. Poet built his Tiny House on a trailer to it can be towed, THOW. He built it and bought a piece of land completely off grid. There is no grid power available. There is a well on the property that requires 240V AC to power it. Right now, Poet, uses a Honda Generator model EU7000 which can output 120V and 240V split-phase like we use. The well pump is submersible, inside the well. The cord comes out of the well and has a 30 amp twist-lock plug on the end. This is what he plugs into the generator to run his well. This means that in order to have water inside his tiny house, Poet must fire up his generator. This is costly, noisy, and inconvenient.
I'm building Poet a solar power system to handle his needs for the well pump, and a future air conditioner. Below are some of the parts I'm using:
Inverter: I'm using the Growatt SPF 5000 ES model. This inverter has a built-in solar MPPT charge controller (up to 6,000 watts of solar). It can output up to 5000 watts of AC power at 240V 60 hertz. This inverter can also charge the batteries from an AC source, such as his generator. I bought the inverter from Signature Solar.
Auto-Transformer: This device can "split" the 240VAC output into two legs of 120V each. In North America many household appliances run on 120V. This was also bought from Signature Solar.
Update: There is no longer a discount code available.
Circuit Breakers and box: These were purchased from Industrial Control Direct. No affiliate. industrialcontroldirect.com/circuit-protection-60/imo-ul489-circuit-breakers-552
Din-Rail Box: industrialcontroldirect.com/enclosures-4326.html
Ebay affiliate link:
Large DC circuit breaker: ebay.us/6uLDdz
Amazon Affiliate Links:
Fuse Holder, UL: amzn.to/3DLrscL
“As an Amazon Associate I earn from qualifying purchases.”
Affiliate Links:
Growatt 5000W Inverter with 450V MPPT Charge Controller 5000ES: signaturesolar.com/growatt-48v-5kw-450vdc-stackable-off-grid-inverter/?ref=4_rHcgZ9x-TiF-
Auto-Transformer, 5000ES: signaturesolar.com/growatt-5kw-split-phase-transformer/?ref=4_rHcgZ9x-TiF-
EG4 Battery, 48V, 100Ah, 5.12kWh, LiFePO4, Server Rack design: signaturesolar.com/shop-all/batteries/?ref=4_rHcgZ9x-TiF-
Waterproof EG4 battery: 48V LiFePO4 Lithium Battery with Bluetooth, EG4 Brand: signaturesolar.com/eg4-wp-lithium-battery-48v-100ah?ref=4_rHcgZ9x-TiF-
Disclaimer:
My videos are in no way intended to be instructional "how-to" lessons. I am simply documenting my project for informational purposes. Property damage, personal injury, or death may result, even when following manufacturer's instructions. I cannot be held liable for such damage or injury. It is YOUR OBLIGATION to ensure that you are complying with any local and federal laws as well as code and permit requirements.
David Poz, LLC
The inverter is from Growatt. It's the SPF 5000ES model. It can output a continuous 5000 watts (5kW) of AC power at 230 or 240 volts (50 or 60 hertz). I'm using an auto-transformer from Solar Edge to provide a neutral so that I can have 120/240V split-phase. Total output: 15kW Each inverter has a built-in solar MPPT charge controller.
Related videos:
1. Introduction to this inverter: youtu.be/2eF7zxmKBAg
2. Load test of one inverter: youtu.be/yWUfvvSa3K8
3. Parallel 3 inverters wiring: youtu.be/dCQIGPuPHCc
Update: There is no longer a discount code available.
Affiliate Links:
Growatt 5000W Inverter with 450V MPPT Charge Controller 5000ES: signaturesolar.com/growatt-48v-5kw-450vdc-stackable-off-grid-inverter/?ref=4_rHcgZ9x-TiF-
Auto-Transformer, 5000ES: signaturesolar.com/growatt-5kw-split-phase-transformer/?ref=4_rHcgZ9x-TiF-
EG4 Battery, 48V, 100Ah, 5.12kWh, LiFePO4, Server Rack design: signaturesolar.com/shop-all/batteries/?ref=4_rHcgZ9x-TiF-
Waterproof EG4 battery: 48V LiFePO4 Lithium Battery with Bluetooth, EG4 Brand: signaturesolar.com/eg4-wp-lithium-battery-48v-100ah?ref=4_rHcgZ9x-TiF-
Disclaimer:
My videos are in no way intended to be instructional "how-to" lessons. I am simply documenting my project for informational purposes. Property damage, personal injury, or death may result, even when following manufacturer's instructions. I cannot be held liable for such damage or injury. It is YOUR OBLIGATION to ensure that you are complying with any local and federal laws as well as code and permit requirements.
David Poz, LLC
I'm installing this in my garage, workshop, to cool it in the summer, and help heat it in winter. The installation went pretty smooth. The included manual shows you how to install most of the parts.
I installed this in the middle of summer, and it's hot! After 48 hours of run-time the mini-split had the whole garage cooled to 64°F and is only drawing a tiny 130 Watts to maintain that temperature! Wow! That's amazing how the inverter driven compressor can draw so little power.
The manual says to just pull a vacuum using a vacuum pump. However, I also include using a nitrogen tank to pressure test the system and check for leaks.
Since this mini-split can run on straight 240V (no neutral) I can run this on my Growatt inverters that I installed in a previous video. Actually, I could install up to 5 of these mini-split air conditioners on just one Growatt 5000 inverter. That's a cool way to move some loads off the grid.
To purchase the 38 SEER heat pump go here: signaturesolar.com/innovair-mini-split-ac-heat-pump-9000-btu/?ref=4_rHcgZ9x-TiF-
This is an affiliate link. I'm sorry to say the discounts have expired.
Signature Solar provided this unit at no cost for the purpose of a review. However, the thoughts and opinions expressed in this video are mine and mine alone. Thanks for watching, David.
Amazon affiliate links:
Vacuum pump and gauge set: amzn.to/3jAG9WO
Flare Tool eccentric cone: amzn.to/3CsnBRx
Nylog sealant: amzn.to/3CpzBD4
Lineset cover: amzn.to/2WVNloU
Deburring Tool: amzn.to/3AnFrmy
“As an Amazon Associate I earn from qualifying purchases.”
Affiliate Links:
Growatt 5000W Inverter with 450V MPPT Charge Controller 5000ES: signaturesolar.com/growatt-48v-5kw-450vdc-stackable-off-grid-inverter/?ref=4_rHcgZ9x-TiF-
Auto-Transformer, 5000ES: signaturesolar.com/growatt-5kw-split-phase-transformer/?ref=4_rHcgZ9x-TiF-
EG4 Battery, 48V, 100Ah, 5.12kWh, LiFePO4, Server Rack design: signaturesolar.com/shop-all/batteries/?ref=4_rHcgZ9x-TiF-
Waterproof EG4 battery: 48V LiFePO4 Lithium Battery with Bluetooth, EG4 Brand: signaturesolar.com/eg4-wp-lithium-battery-48v-100ah?ref=4_rHcgZ9x-TiF-
Disclaimer:
My videos are in no way intended to be instructional "how-to" lessons. I am simply documenting my project for informational purposes. Property damage, personal injury, or death may result, even when following manufacturer's instructions. I cannot be held liable for such damage or injury. It is YOUR OBLIGATION to ensure that you are complying with any local and federal laws as well as code and permit requirements.
David Poz, LLC
Outback pre-wired panel: shopsolarkits.com/products/flexpower-8kw-48v-pre-wired-radian-system-120-240v-with-300vdc-100a-cc?_pos=11&_sid=ab60f6c75&_ss=r&ref=s_fx9xj-vyvj (affiliate link)
Amazon Affiliate Links:
Bus Bars for combining batteries: amzn.to/3hkNoSS
“As an Amazon Associate I earn from qualifying purchases.”
If you would like to be featured in a video, please contact me. Currently only the North-East area of the US (VT, NH, ME, MA, CT, RI, NY, NJ, PA) Write "Interview" in the subject line. davidpoz.com/contact
I bought these batteries from Signature Solar and they are awesome! I've been running my house off grid with them for 2 months 24/7. There have been zero issues. They just work perfect.
Update: There is no longer a discount code available.
In this video I test how well the load is balanced between the batteries. I check the amps going into each from the bus bars. I find they are sharing the load within 1.5% of each other, which is great.
Previous videos about the battery:
Introduction, tear-down: youtu.be/SYJ25izYSGc
Cabinet stacking: youtu.be/89MyA7zPdYI
This is all part of my overall goal to be energy independent. I'm trying to power my whole house and garage off the grid. And this is with an all electric home. That includes cooking and heating. Join me for learning with me along the way. Right now I'm confident I can survive a power outage, or black out. But I'm still shy of being completely off grid.
Affiliate Links:
Growatt 5000W Inverter with 450V MPPT Charge Controller 5000ES: signaturesolar.com/growatt-48v-5kw-450vdc-stackable-off-grid-inverter/?ref=4_rHcgZ9x-TiF-
Auto-Transformer, 5000ES: signaturesolar.com/growatt-5kw-split-phase-transformer/?ref=4_rHcgZ9x-TiF-
EG4 Battery, 48V, 100Ah, 5.12kWh, LiFePO4, Server Rack design: signaturesolar.com/shop-all/batteries/?ref=4_rHcgZ9x-TiF-
Waterproof EG4 battery: 48V LiFePO4 Lithium Battery with Bluetooth, EG4 Brand: signaturesolar.com/eg4-wp-lithium-battery-48v-100ah?ref=4_rHcgZ9x-TiF-
Disclaimer:
My videos are in no way intended to be instructional "how-to" lessons. I am simply documenting my project for informational purposes. Property damage, personal injury, or death may result, even when following manufacturer's instructions. I cannot be held liable for such damage or injury. It is YOUR OBLIGATION to ensure that you are complying with any local and federal laws as well as code and permit requirements.
David Poz, LLC
This battery was from Battery Hookup. However, it is currently out of stock. Here is a link to my current favorite battery available from Battery Hookup:
batteryhookup.com/products/k2-12-8v-142-95ah-1855wh-lifepo4-module
Use coupon code: DAVIDPOZ for a discount, and to help the channel through the affiliate program.
To see Part 1, disassembling the first module, go here: youtu.be/GqyZ1dBaGQw
Video describing BMS options: youtu.be/jT7_VImZYM0
If you enjoy this content and would like to help support the channel please go to: patreon.com/DavidPoz
Disclaimer:
My videos are in no way intended to be instructional "how-to" lessons. I am simply documenting my project for informational purposes. Property damage, personal injury, or death may result, even when following manufacturer's instructions. I cannot be held liable for such damage or injury. It is YOUR OBLIGATION to ensure that you are complying with any local and federal laws as well as code and permit requirements.
I'm wiring these inverters with a solar-edge auto transformer. This allows me to split the 240v into two 120v legs. This provides the 120/240 volt split-phase power we use in North America.
DIY Powerwall!
Update: There is no longer a discount code available.
Related Videos:
Inverter Initial review, Part 1: youtu.be/2eF7zxmKBAg
Inverter Load Testing: youtu.be/yWUfvvSa3K8
Battery Initial Review: youtu.be/SYJ25izYSGc
Battery Cabinet assembly: youtu.be/89MyA7zPdYI
Wiring Solar Arrays: youtu.be/wDTkMQY3Rx0
Amazon Affiliate Links:
Rubber Grommets: amzn.to/3w1ZSnE
Victron Smart Shunt 500: amzn.to/2S66PFx
Ferrule kit: amzn.to/34R3mNN
Watt Meter: amzn.to/3w0JkfK
4-Pole IMO disconnect switch: amzn.to/3yIuqMO
“As an Amazon Associate I earn from qualifying purchases.”
Affiliate Links:
Growatt 5000W Inverter with 450V MPPT Charge Controller 5000ES: signaturesolar.com/growatt-48v-5kw-450vdc-stackable-off-grid-inverter/?ref=4_rHcgZ9x-TiF-
Auto-Transformer, 5000ES: signaturesolar.com/growatt-5kw-split-phase-transformer/?ref=4_rHcgZ9x-TiF-
EG4 Battery, 48V, 100Ah, 5.12kWh, LiFePO4, Server Rack design: signaturesolar.com/shop-all/batteries/?ref=4_rHcgZ9x-TiF-
Waterproof EG4 battery: 48V LiFePO4 Lithium Battery with Bluetooth, EG4 Brand: signaturesolar.com/eg4-wp-lithium-battery-48v-100ah?ref=4_rHcgZ9x-TiF-
Disclaimer:
My videos are in no way intended to be instructional "how-to" lessons. I am simply documenting my project for informational purposes. Property damage, personal injury, or death may result, even when following manufacturer's instructions. I cannot be held liable for such damage or injury. It is YOUR OBLIGATION to ensure that you are complying with any local and federal laws as well as code and permit requirements.
David Poz, LLC
Previous videos:
Growatt Inverter SPF 5000 ES Introduction:
Growatt Inverter Load Testing:
Solar Array Build:
Affiliate Links:
Growatt Inverter SPF 5000 ES: shop.signaturesolar.us/products/5kw-48w-240vac-80a-off-grid-inverter-by-growatt
Use code: DAVIDPOZ at checkout for a discount on your purchases from Signature Solar.
IMO Switch. Note, this link is not an affiliate link. I have found that buying two smaller switches is less expensive than this big one. I have provided a link below to Amazon where you can find them less expensive. industrialcontroldirect.com/dc-disconnect-si25-pel64r-8-4094.html
Amazon Affiliate Link:
4-Pole IMO disconnect switch: amzn.to/3yIuqMO
Cable Glands (strain relief): amzn.to/3uwesSG
Wire, 12 gauge THHN Black: amzn.to/3vwOUpD
Wire, 12 AWG, THHN, Red: amzn.to/3yJH9ih
Wire Pulling Lubricant: amzn.to/3hXRl0I
Mule Tape: amzn.to/3p4KBj1
“As an Amazon Associate I earn from qualifying purchases.”
Half this video is setting up the wiring for the bottom water heater element on my hot water tank. This will server two functions. First, it gives me a fixed load for capacity tests (which I'm doing in this video). Second, it will allow me to wire the bottom element to a relay and control it as a diversion load. I'm not doing the diversion relay in this video, that will be in a future video. In this video I'm just manually turning on the water heater with the circuit breaker.
All the batteries in this video were purchased at batteryhookup.com you can use my coupon code DAVIDPOZ for a discount. The code also helps out the channel through the affiliate program. Thanks.
Amazon Affiliate links:
Built-in water heater element: amzn.to/3hty5b2
Thermostat: amzn.to/3fmPIqw
Victron Smart Shunt (I use the 500 amp version) amzn.to/3hshLr0
“As an Amazon Associate I earn from qualifying purchases.”
If you would like to help support the channel please go to patreon.com/DavidPoz Thank you.
Please check with your local codes to ensure you work legally and safely.
To purchase similar batteries, go to batteryhookup.com Use discount code DAVIDPOZ for 5% off your order. This code is also an affiliate code, so it helps out this channel. Thank you.
Video Links:
Bens Sol-Ark 12K inverter: youtu.be/7zoPu-uK4Xc
Bens Battery Bank: youtu.be/i22xYD3DuWY
Video describing cell arrangement (16s, 14s, etc.) in more detail: youtu.be/CbHABrTpSKU
Link to Bens Channel: youtube.com/channel/UCKIySgKlPTGI_aQ_74LGhaQ/featured
To purchase similar batteries, go to batteryhookup.com Use discount code DAVIDPOZ for 5% off your order. This code is also an affiliate code, so it helps out this channel. Thank you.
This all-in-one inverter is one of the least expensive inverters on the market. It works with 48v DC battery, and has solar MPPT input. It can handle up to 6000 watts of solar input. The inverter outputs 240v AC only. So I also demonstrate how to use a solar edge auto-transformer to split the single phase into two 120v legs. This provides the 120/240 volt split-phase we use in North America.
Part 1 video: youtu.be/2eF7zxmKBAg
Update: There is no longer a discount code available.
Amazon Affiliate links:
DC watt meter: amzn.to/3dKG9BT
AC watt meter: amzn.to/3aFTklX
“As an Amazon Associate I earn from qualifying purchases.”
Affiliate Links:
Growatt 5000W Inverter with 450V MPPT Charge Controller 5000ES: signaturesolar.com/growatt-48v-5kw-450vdc-stackable-off-grid-inverter/?ref=4_rHcgZ9x-TiF-
Auto-Transformer, 5000ES: signaturesolar.com/growatt-5kw-split-phase-transformer/?ref=4_rHcgZ9x-TiF-
EG4 Battery, 48V, 100Ah, 5.12kWh, LiFePO4, Server Rack design: signaturesolar.com/shop-all/batteries/?ref=4_rHcgZ9x-TiF-
Waterproof EG4 battery: 48V LiFePO4 Lithium Battery with Bluetooth, EG4 Brand: signaturesolar.com/eg4-wp-lithium-battery-48v-100ah?ref=4_rHcgZ9x-TiF-
Disclaimer:
My videos are in no way intended to be instructional "how-to" lessons. I am simply documenting my project for informational purposes. Property damage, personal injury, or death may result, even when following manufacturer's instructions. I cannot be held liable for such damage or injury. It is YOUR OBLIGATION to ensure that you are complying with any local and federal laws as well as code and permit requirements.
David Poz, LLC
Amazon Affiliate Links:
12v Water Pump: amzn.to/3wEEPrH
Pump Filter: amzn.to/3wF0Kz9
“As an Amazon Associate I earn from qualifying purchases.”
The outdoor tool shed is fully insulated with Dense-pack cellulose insulation. Some would say it's super insulated. The walls and floor are about an R-42. The ceiling is more because it's packed all the way to the roof. This is known as a hot roof since there is no venting.
I removed the tools, and siding from one wall. I installed two new windows. These windows are double hung, double pane, insulated glass. Not the lowest U-factor, but it's OK. Having two windows allow for a cross breeze when both are open.
Since there was no heating system, I needed to add one. We decided on an electric radiant floor. This was a DIY kit with the electric resistance wire already attached to a mat. This mesh mat made installation fast and easy. The kit is called from LuxHeat. Link below.
After that I used a self-leveling compound (similar to thin-set, or cement). This was poured 1/2" thick to embed the wires. I had some real trouble with this step as you see in the video.
The walls are covered in bead board paneling and painted white. There are 6 recessed LED light fixtures. The floor is a oak laminate, floating floor.
Thanks to my wife and daughter for helping in the build.
Amazon Affiliate Links:
Radiant Floor: amzn.to/31Gd0Ry
LED Lights: amzn.to/39Amrq3
(the exact model I used is not sold anymore, this is a very close one)
“As an Amazon Associate I earn from qualifying purchases.”
This is just my first part of my testing and review of the Growatt SPF5000ES inverter/charger. This is an all in one unit with a 5kw inverter, 80 amp AC charger, 100 amp solar MPPT charge controller. It's a great value at only $900 at the time of this video.
This is a 48v inverter/charger made for off grid use. You can use the grid for charging your batteries as a backup, but not for back-feeding the grid. It's single phase, 240v AC only. So you will need a transformer if you want to get 120/240v split phase out of this. I'll go into more details on the split phase in an upcoming video.
This is the best value, cheapest, inverter I've tested so far. Yes, it's cheap at $900 for all the components you get. In future videos I'll continue testing to see how well it holds up.
Update: There is no longer a discount code available.
Affiliate Links:
Growatt 5000W Inverter with 450V MPPT Charge Controller 5000ES: signaturesolar.com/growatt-48v-5kw-450vdc-stackable-off-grid-inverter/?ref=4_rHcgZ9x-TiF-
Auto-Transformer, 5000ES: signaturesolar.com/growatt-5kw-split-phase-transformer/?ref=4_rHcgZ9x-TiF-
EG4 Battery, 48V, 100Ah, 5.12kWh, LiFePO4, Server Rack design: signaturesolar.com/shop-all/batteries/?ref=4_rHcgZ9x-TiF-
Waterproof EG4 battery: 48V LiFePO4 Lithium Battery with Bluetooth, EG4 Brand: signaturesolar.com/eg4-wp-lithium-battery-48v-100ah?ref=4_rHcgZ9x-TiF-
Disclaimer:
My videos are in no way intended to be instructional "how-to" lessons. I am simply documenting my project for informational purposes. Property damage, personal injury, or death may result, even when following manufacturer's instructions. I cannot be held liable for such damage or injury. It is YOUR OBLIGATION to ensure that you are complying with any local and federal laws as well as code and permit requirements.
David Poz, LLC
This is the fastest large battery build I've ever done. In just one hour I was able to load the batteries, wire up and be ready to go.
If you buy from Signature Solar please use the discount code DAVIDPOZ This will get you 5% off, and tracks the affiliate program which will help the channel.
This is comprised of 6 battery modules. Each module is 5.12kwh Gyll LiFePO4 battery with it's own BMS and circuit breaker. For more details on the single Gyll Battery Module check out my previous video: youtu.be/SYJ25izYSGc
Affiliate Links:
Growatt 5000W Inverter with 450V MPPT Charge Controller 5000ES: signaturesolar.com/growatt-48v-5kw-450vdc-stackable-off-grid-inverter/?ref=4_rHcgZ9x-TiF-
Auto-Transformer, 5000ES: signaturesolar.com/growatt-5kw-split-phase-transformer/?ref=4_rHcgZ9x-TiF-
EG4 Battery, 48V, 100Ah, 5.12kWh, LiFePO4, Server Rack design: signaturesolar.com/shop-all/batteries/?ref=4_rHcgZ9x-TiF-
Waterproof EG4 battery: 48V LiFePO4 Lithium Battery with Bluetooth, EG4 Brand: signaturesolar.com/eg4-wp-lithium-battery-48v-100ah?ref=4_rHcgZ9x-TiF-
Disclaimer:
My videos are in no way intended to be instructional "how-to" lessons. I am simply documenting my project for informational purposes. Property damage, personal injury, or death may result, even when following manufacturer's instructions. I cannot be held liable for such damage or injury. It is YOUR OBLIGATION to ensure that you are complying with any local and federal laws as well as code and permit requirements.
David Poz, LLC
Retail price as of this video is $1,500, which is less than $300/kwh.
Update: There is no longer a discount code available.
In the video I do a full capacity test. I test the BMS for over-current protection, and over-voltage protection. Finally I connect the battery to my computer to see what can be read.
Overall, I'm very impressed with the build quality of this battery. I think it's the cheapest at $300/kwh. I haven't seen any other 48v LiFePO4 batteries (pre-built with BMS) come close to this price point.
Amazon Affiliate Links:
Resistor used to pre-charge inverter: amzn.to/30lgg4c
“As an Amazon Associate I earn from qualifying purchases.”
Affiliate Links:
Growatt 5000W Inverter with 450V MPPT Charge Controller 5000ES: signaturesolar.com/growatt-48v-5kw-450vdc-stackable-off-grid-inverter/?ref=4_rHcgZ9x-TiF-
Auto-Transformer, 5000ES: signaturesolar.com/growatt-5kw-split-phase-transformer/?ref=4_rHcgZ9x-TiF-
EG4 Battery, 48V, 100Ah, 5.12kWh, LiFePO4, Server Rack design: signaturesolar.com/shop-all/batteries/?ref=4_rHcgZ9x-TiF-
Waterproof EG4 battery: 48V LiFePO4 Lithium Battery with Bluetooth, EG4 Brand: signaturesolar.com/eg4-wp-lithium-battery-48v-100ah?ref=4_rHcgZ9x-TiF-
Disclaimer:
My videos are in no way intended to be instructional "how-to" lessons. I am simply documenting my project for informational purposes. Property damage, personal injury, or death may result, even when following manufacturer's instructions. I cannot be held liable for such damage or injury. It is YOUR OBLIGATION to ensure that you are complying with any local and federal laws as well as code and permit requirements.
David Poz, LLC
Update: I made a mistake in the spreadsheet. When I did my conversion from cubic inches to cubic feet I divided by the area factor, not volume factor. The cubic feet volume of the original battle born should read 0.46, and the new model 1.23. Both have the same volume to kwh ratio of 0.38 cu.ft./kwh. Sorry for the mistake, Thank you to David James for pointing it out to me in the comments.
New Gamechanger model BBgc3: battlebornbatteries.com/product/270ah-12v-lifepo4-deep-cycle-gc3-battery
Flagship model BB10012: battlebornbatteries.com/product/12v-lifepo4-deep-cycle-battery
These are not affiliate links. I'm not affiliate with Battle Born.
I'm testing all my DMM, Digital Multi-meters. I'm testing them against my Victron Smart Shunt 500 for accuracy. Since the Victron Smartshunt is Bluetooth, we will see what it's recording on the phone app. I want to find out which one is most accurate. I also test my DIY capacity tester meter (built in a previous video). Finally I calibrate my capacity tester using a rotary tool.
Video making capacity tester: youtu.be/sJ-sy8Osqr0
Amazon Affiliate Links:
Uni-T Multi-Meter 210E: amzn.to/3ks9jYe
The next multi-meter to buy, UT216C: amzn.to/3kAgNZy
Capacity Tester: amzn.to/2O9melN
Victron SmartShunt 500a: amzn.to/3ksgpMw
“As an Amazon Associate I earn from qualifying purchases.”
If you would like to help support the channel please go here: patreon.com/DavidPoz
Amazon Affiliate Links:
Evolution Saw: amzn.to/3jPczwL
“As an Amazon Associate I earn from qualifying purchases.”
To help support the channel please go here: patreon.com/DavidPoz