Old School Fire AlarmsIn 1962 an absolutely beautiful High school was constructed in Akron, Ohio. At the time this school was considered a crown jewel for Akron Public Schools. The school was named in honor of Harvey S. Firestone (1868-1938), a tire industrialist, who along with three associates organized and built the Firestone Tire & Rubber Company.
The school was furnished with a Standard Electric Time, model # UAX-3 (circa 1958) fire alarm system. Considered at the time to be one of the very best systems ever designed and manufactured. After 58 years of fire drills, this Standard Electric Time system still works like a charm and could easily go another 58 years. Sadly, this school was demolished in 2016.
STANDARD ELECTRIC TIME FIRE ALARM SYSTEM @ FIRESTONE HIGHOld School Fire Alarms2016-08-23 | In 1962 an absolutely beautiful High school was constructed in Akron, Ohio. At the time this school was considered a crown jewel for Akron Public Schools. The school was named in honor of Harvey S. Firestone (1868-1938), a tire industrialist, who along with three associates organized and built the Firestone Tire & Rubber Company.
The school was furnished with a Standard Electric Time, model # UAX-3 (circa 1958) fire alarm system. Considered at the time to be one of the very best systems ever designed and manufactured. After 58 years of fire drills, this Standard Electric Time system still works like a charm and could easily go another 58 years. Sadly, this school was demolished in 2016.The Vandalized Fire AlarmOld School Fire Alarms2022-12-15 | Bettes Elementary School was constructed in 1927 and equipped with a manual pull rod fire alarm system. In 1952 additional classrooms were added to the building. It was at this time the fire alarm system was upgraded with electrical IBM hardware that automated the entire system. In 2018 - 2019 the school was closed due to redistricting and sold at public auction. The new owners intended to repurpose the old school building and use it for a community center. Due to lack of funding the project never came to fruition. Sadly, the building was breached by metal scrapers and vandals and fell into a total state of disrepair. As of February 2023, this school has been demolished.A FIRE ALARM REUNION @ Pfeiffer Elementary SchoolOld School Fire Alarms2021-09-24 | Back in 2008, Pfeiffer Elementary School's fire alarm system was one of the very first I filmed for my You Tube channel and website, Old School Fire Alarms. Construction of Pfeiffer began in 1917 and was completed and dedicated in 1919. The school was named after two brothers, Jacob and William Pfeiffer, who donated the land the school is built on. The school was originally known as, "Overlook", named after the land it was built on. It wasn't until 1919 that the school was dedicated and renamed, Pfeiffer School.
When the school was first built, a pull rod fire alarm system, using 10 inch manual trip bells was installed. In 1959 the system was updated and automated with an Autocall fire alarm control panel, using Vibratone horns as the signaling devices. The code on the control panel is the Cadence Marching Code 4-4-4-4. It was designed to assure a quick and orderly evacuation of any building.
The school as of this writing is 104 years old and was built at a time when many school buildings of this caliber were used as fallout shelters, especially during World War II. This school and fire alarm system have endured the test of time, and are examples of fine craftmanship when things were built to last.The Abandoned Fire AlarmOld School Fire Alarms2020-05-22 | Unfortunately, many old schools like the one shown in this video are being demolished at an alarming rate (pardon the pun). With their destruction many historical artifacts are also destroyed, like old fire alarm systems. These old schools are often times replaced with cheaply constructed new ones, that only have a mere lifespan of 30 years.OLD IBM/SIMPLEX FIRE ALARM @ ELLET HIGH SCHOOLOld School Fire Alarms2020-04-11 | Ellet High School was built in 1948 in Akron, Ohio. When the school was originally constructed, a pull rod fire alarm system was installed and automated with an IBM 4201-2 control panel using 8 inch, IBM single stroke bells. As time marched on, the school was expanded and the fire alarm system extended. The old IBM panel was eventually replaced with a Simplex 4208 control panel. The original IBM single stroke bells were left in place and tied into the newer Simplex control panel. The original 8 pull rod stations were also left in place in the event of an electrical outage. Sadly, the school was demolished in 2020. I am happy to report that shortly before demolition, the old fire alarm system was removed and saved for historical preservation.Old Cleveland School Fire AlarmOld School Fire Alarms2019-02-27 | I am overjoyed to report that this school is still standing and in full operation as of 2023. The school's original name was, Miles Standish. Later it was renamed after a former Cleveland mayor, Michael R. White. Today the school is part of the Stonebrook-White Montessori Campus. It is in the Cleveland Metropolitan School District. The school had been slated for demolition when this film was first produced in 2018. Those original plans have since changed and the school is no longer scheduled to be demolished.GARFIELD HIGH SCHOOL FIRE ALARMOld School Fire Alarms2018-05-03 | Garfield High School was originally built with a pull rod fire alarm system. Ten inch manual trip bells were used for the signaling devises. In the 1950's, due to a change in fire code regulations, the pull rod system was automated with an electric Autocall fire alarm system using 8 inch, single stroke bells. Then in the late 1980's, the system was updated again with Simplex fire alarm hardware, utilizing a Simplex 2001-8001 master control panel. The Simplex hardware was integrated with the old pull rod and Autocall fire alarm system. Sadly, this particular school has been demolished and replaced with a new school building.Simplex Fire Alarm Code 3Old School Fire Alarms2017-09-07 | This school was originally built in 1956 with a Reiter, manual pull rod fire alarm system that used 10 inch manual trip bells for the signaling devices. Sometime in the 1980's, the old manual pull rod system was upgraded and automated with a Simplex 4002 fire alarm system that uses horns and strobe lights for the signaling devices. When the system is activated, either by the pull rod or Simplex pull stations, it signals code 3 over the horns and strobe lights.The Invisible Pull Rod Fire Alarm SystemOld School Fire Alarms2017-07-05 | This unique fire alarm system was designed and manufactured by the Reiter Company, long out of business that was in Canton, Ohio. This particular system was installed in a school that was originally built in 1927 and later had several additions added to the building. It is a manual, pull rod fire alarm system where the pull rod, instead of being mounted on the outside of the wall, is built into the wall where it can't be seen. It is activated by pull handles that are mounted on each floor. In 1993, a Simplex fire alarm control panel (Model 4002) with electric horns was added to automate the entire system.GOODRICH MIDDLE SCHOOL FIRE ALARMOld School Fire Alarms2017-03-29 | Goodrich was originally built as an elementary school and later became a middle school. Built in 1930, this elaborately adorned school was named after, Benjamin Franklin Goodrich (born on November 4, 1841 and died August 3, 1888), who was an American rubber industrialist and founder of the B. F. Goodrich Company in Akron, Ohio.
A pull rod fire alarm system using manual trip bells was originally installed when the school was first constructed. In the early 1950's the pull rod was automated with an electric Autocall fire alarm system using 10 inch, single stroke bells. After hundreds of fire drills and decades of use, this vintage fire alarm system still works great!
Goodrich was decommissioned and closed in 2010 due to low student population and redistricting. Since then, the school was sold at public auction and the new owner donated it to a church, who attempted to repurpose the building into a community center. Shortly thereafter, due to the lack of funding, the school fell into a state of total disrepair.
As of 2023, this school building has been breached by metal scrapers and destroyed by vandals. It is just a matter of time before the city of Akron will order this school building demolished.AUTOCALL FIRE ALARM SYSTEM @ HOTCHKISS ELEMENTARYOld School Fire Alarms2017-01-15 | Hotchkiss Elementary is a modest, smaller school in Akron, Ohio. This school was originally built in 1927 with a manual pull rod fire alarm system. In the early 1950's the pull rod was automated with an electric, Autocall fire alarm system. Non-coded pull stations with 10 inch, single stroke bells were installed throughout the two story building.
My father, who was born in 1929, attended this school when he was a boy. So I could not help feeling nostalgic as I walked the hallways and roamed throughout the building. Sadly, this school has been decommissioned and is now closed awaiting demolition.OLD FIRE ALARM SYSTEMOld School Fire Alarms2016-01-22 | This beautiful old Toledo school was built in 1922 with a manual pull rod fire alarm system. In 1940, the system was automated with an electric Autocall control panel using vibrating horns as the signaling devices. The code is the cadence marching code, 4-4-4-4 that signals four complete rounds. This particular code always assured a quick and orderly evacuation of any building. Sadly, as with so many old, magnificent schools of this caliber, it too was demolished in 2011.OLD SCHOOL FIRE ALARMS: Official TrailerOld School Fire Alarms2015-12-30 | Old School Fire Alarms is dedicated to the history, collection, and preservation of vintage fire alarm systems; particularly manual pull rod systems that have been salvaged from old school buildings scheduled for demolition. To learn more, please visit: OldSchoolFireAlarms.comIBM FIRE ALARM SYSTEM @ BETTES ELEMENTARY SCHOOLOld School Fire Alarms2015-12-25 | Bettes School was originally constructed in 1927 in Akron, Ohio with a manual Pull Rod Fire Alarm system using 10 inch trip bells. In 1952, the system was updated with an IBM electric fire alarm system using 10 inch, electric, single stroke bells. The code is 4-4 which is sent out by the IBM master control panel (Model 4201-2). There are non-code IBM pull boxes (Type 4250-1) located throughout the school that can also activate the system. After 92 years, this vintage fire alarm system is still working great and certainly more reliable and easier to maintain then most of the newer systems manufactured today.
UPDATE: This school was closed in 2018 due to low student population and redistricting. It was then sold at public auction in 2019. The new owners intended to repurpose the school to be used as a community center. Due to lack of funding, this plan never materialized and the building has since fallen into total disrepair. Metal scrapers and vandals breached the building resulting in severe damage and deterioration of the school. To see the school and fire alarm's current condition, view the video, The Vandalized Fire Alarm, on YouTube.The Demolition of George Barber Elementary SchoolOld School Fire Alarms2015-09-11 | This magnificent old school was built in Akron, Ohio in 1929 and sadly demolished in 2008 to make way for a new school building.PULL ROD FIRE ALARM @ CASE ELEMENTARYOld School Fire Alarms2015-06-12 | You are viewing the activation of a pull rod fire alarm at Case Elementary School in Akron, Ohio. The pull rod is hooked to a manual, Reiter, brass trip bell and an activation switch that is wired to an electric Autocall fire alarm system. When the rod is pulled, it rings the manual brass bell and triggers the activation switch to signal the electric fire alarm bells that are installed throughout the school. The single stroke fire bells sound the cadence marching time signal, 4-4-4-4. Sadly, this wonderful, well built school was demolished in March of 2016.TRIP BELL / PULL ROD FIRE ALARMOld School Fire Alarms2014-06-14 | You are viewing a pull rod fire alarm being activated at a public elementary school that had three floors. The manual pull rod and trip bells were manufactured by the Reiter Company out of Canton, Ohio. The pull rod and manual trip bells were installed when the school was first built in 1930. Later in 1954 the pull rod was automated with an Autocall fire alarm system. Autocall was one of the first signaling companies established in the United States out of Shelby, Ohio. Double projector, vibrating horns (model 123-S) were the audible devices used that were wired to the Autocall fire alarm control panel shown at the end of the video. The signal code is the cadence marching time 4-4-4-4. Both Reiter and Autocall have long been out of business.FIRE ALARM @ FIRESTONE ELEMENTARY SCHOOLOld School Fire Alarms2014-04-23 | You are viewing the pull rod fire alarm being activated at Firestone Elementary School in Akron, Ohio. Instead of using horns, this system was wired to 10" Autocall single stroke bells. The code is 4-4-4-4 cadence march time which is all automated by the Autocall fire alarm control panel.FIRE ALARM @ GEORGE BARBER ELEMENTARY SCHOOLOld School Fire Alarms2014-04-16 | You are viewing the original pull rod fire alarm being activated at George Barber Elementary School in Akron, Ohio. This beautiful school was built in 1929 and sadly, demolished in 2008.FIRE ALARM @ SCHUMACHER ELEMENTARY SCHOOLOld School Fire Alarms2014-04-10 | You are viewing the original pull rod fire alarm being activated at Schumacher Elementary School in Akron, Ohio. This beautiful school was built in 1929 and sadly, demolished in 2011. The manual pull rod fire alarm was automated in the 1950's with an Autocall fire alarm system that used vibrating horns.VINTAGE AUTOCALL / PULL ROD FIRE ALARMOld School Fire Alarms2014-04-03 | Here for your viewing pleasure is the pull rod fire alarm that was used for 79 years at the original, George Barber Elementary School in Akron, Ohio. You will also see the Autocall fire alarm control panel that was installed in the 1950's that automated the system with electric horns. There were three floors in the building and two pull stations on each floor. One at each end of the hallways. The Autocall control panel that automated the pull rod system was housed in the boiler room on the first floor. Sadly, the original school was demolished in 2008 and replaced with a new school building.Vintage Pull Rod Fire Alarm @ Betty Jane ElementaryOld School Fire Alarms2014-04-02 | This is a pull rod fire alarm being activated at Betty Jane Elementary School in Akron, Ohio. The pull rod is tied into a Standard Electric Time Company fire alarm control panel, which is shown at the end of the video (circa 1940's). The code signal for this particular system was 2-3 which sounded four complete rounds. This school was unfortunately demolished shortly after this video was shot.AUTOCALL FIRE ALARM CONTROL PANEL, circa 1954Old School Fire Alarms2014-03-19 | You are viewing the Autocall fire alarm control panel that operates and automates many manual pull rod fire alarm systems. Autocall made thousands of these panels in the 1950's and 60's. They were very common in public schools and other public institutions. Bells or horns could be wired to the panel along with pull stations/ boxes. You could also tie-in heat detectors and other similar devices. These vintage control panels can still be found today in many older buildings. The code wheel in the middle of the lower panel is 4-4-4-4 cadence march time.VINTAGE PULL ROD FIRE ALARM SYSTEMOld School Fire Alarms2014-03-08 | This is a manual pull rod fire alarm system that was automated in the 1950's with an Autocall fire alarm system that had 10" single stroke bells. The signal is 4-4-4-4 cadence march time. Instead of pulling the rod, I simply pulled down the lever on the actuator switch that is attached to the pull rod.FIRE ALARM @ Pfeiffer Elementary SchoolOld School Fire Alarms2014-02-25 | This is a manual pull rod / Autocall fire alarm system being activated at a public school building. This fire alarm system was updated in the 1950's with an Autocall fire alarm control panel and vibrating horns. They sure don't make fire alarms like this anymore.George Barber Elementary School Fire AlarmOld School Fire Alarms2014-02-23 | This is the original pull rod fire alarm being activated at George Barber Elementary School in Akron, Ohio. The original school was built in 1929 and sadly, demolished in 2008. A new school has been built on the original site and still maintains the name, George Barber Elementary.