Dave Willmann Electrical
VLOG #6 Hospital Rough In Updates, Onsite antics, Insulation Resistance testing, Data Cableporn
updated
What's in the bag, you ask? Well, only the finest gear to make me look far more professional than I actually am. We've got not one, but TWO Fluke multimeters – because apparently one just isn't enough when you're diagnosing those angry pixies infesting your electrical system.
Then there’s the 289 – the fancy Fluke multimeter that’s got more buttons than I know what to do with, but it makes me feel like a scientist instead of just a sparky. The 378 clamp meter? Oh yeah, because sometimes you just need to see if the cables are alive without getting a cheeky zap. Plus, my thermal imager – because finding hot spots isn't just for the dance floor, am I right?
And of course, the leakage clamp tester, because when it comes to leakage, it’s better to find it in the circuits than in your pants.
This is the toolkit that makes me look like I’ve got my life together (mostly). Tune in and get a sneak peek at how I convince the world I'm a proper electrician!
Like, comment, and let me know how much better your toolbag is – or how much better mine is, which is probably more accurate.
Discription brought to you by ChatGPT because I type slower than a chimpanzee with parkinsons.
Check out my Instagram for daily antics, tools and tips - instagram.com/willmannelectrical
#electrical #fluke #tools
Still dialing in the setup, but I’ve packed it with the essentials – mostly high-quality German tools I’ve collected over the years. This bag comes with me for initial inspections, switchboard testing, fault-finding, logging and power analysis. Nothing in here’s for show – it’s all gear I trust when I’m under the pump. If you’re setting up something similar or just keen for ideas, here’s how mine’s coming together so far.
Written and directed by ChatGPT 😘
Check out my Instagram for daily antics, tools and tips - instagram.com/willmannelectrical
#electrical #tools #toolbag
@NewAgeElectricalCo
#electrical
#sparky
#tools
Check out my Instagram for more content - instagram.com/willmannelectrical
Hope It gives you some ideas for tools to add to your kit!
Check out my insta for more - instagram.com/willmannelectrical
#tools #electrician #vetopropac
The weather was a little crazy 30C+ day one when we manhandled the cables and 15C the next whilst we finished terminations and tested, wish it was the other way around.
I scratch the surface regarding the Automatic Transfer Switching and bust out the 1664FC Jellybean to test our cabling.
Check out my Instagram for daily antics/tools/tips - instagram.com/willmannelectrical
#electrical #sparky #generator
If you've been missing me too much you can get daily antics over on my insta page - instagram.com/willmannelectrical
Check out my Instagram here - instagram.com/willmannelectrical
#sparky
#faultfinding
check out my insta for all the toolporn 😎
Callouts are a bit of fun every now and then! Fault finding is one of the most enjoyable parts of the trade for me. Follow along and I'll try and teach you a bit and you can teach me in the comments!
To bad I can't animate for shit or I would have done some @dsesuk level HIV+ visual AIDS instead of my poorly thought out, scribbled, overtired explanation haha
More antics available on insta - instagram.com/willmannelectrical
If you have any tips for installing these please post a comment below
Check out my instagram for daily hijinks - instagram.com/willmannelectrical
Quick loadout here guys - enjoy!
check out my insta instagram.com/willmannelectrical
Check out my instagram: instagram.com/willmannelectrical
My instagram - instagram.com/willmannelectrical
Marketing wank from Milwaukee website - blah blah :
The M18™ FORCE LOGIC™ 12T Utility Crimper is the Easiest Way to Crimp. Engineered to reduce weight and improve balance, it is the lightest and only fully balanced 12T crimper, with a 350˚ rotating head and red alignment marks making it the Lightest, Most Balanced and Easiest Crimper to Align. Predictive Force Monitoring (PFM™) constantly measures force output to deliver consistent speed that won’t bog down on larger connectors while delivering accurate pressure, every time. The only tool that provides instant pressure verification with a green indicator. The only tool that has pre-crimp battery check that automatically ensures enough battery charge to complete each crimp. The only tool that once a crimp is engaged, has auto-complete to ensure full pressure is reached. Milwaukee® Crimpers feature a fully enclosed high speed hydraulic pump, POWERSTATE™ Brushless Motor, REDLINK™ Electronics and REDLITHIUM™ batteries delivering longer life and Ultimate Reliability in tough conditions.Featuring Milwaukee® ONE-KEY™ Technology, Milwaukee® Crimpers enable you to store real time crimp data, generate professional reports, view historical tool performance data and sync it all wirelessly to the cloud for easy access. Like all ONE KEY™ tools Milwaukee® Crimpers feature tool tracking, allowing you to pinpoint missing tools quicker and inventory management which creates a central place for you to track all tools and equipment across your network of jobs and users.
#electrician #electrical #circuitbreaker
instagram.com/willmannelectrical
It took two attempts but we got there in the end, couple of speed bumps along the way but onward and upward! Thanks for tuning back in.
instagram.com/willmannelectrical
Check out my insta for daily site antics/tool porn : instagram.com/willmannelectrical
Check out my insta: instagram.com/willmannelectrical
Check out my insta: instagram.com/willmannelectrical
Check out my insta : instagram.com/willmannelectrical
#tools #electrician #construction #toolbag
my insta - instagram.com/willmannelectrical
#electrician #sparky #construction
Insta: instagram.com/willmannelectrical
#cableties #electrical #electrician
My Instagram - instagram.com/willmannelectrical
#kwh #electricity #electrician
My instagram - instagram.com/willmannelectrical
Follow along with some of the preliminary testing I've been doing on my cardiac rated operating theater. Ceiling should be sheeted soon and I needed to check that everything is up to code as per AS3003:2018 the Patient Areas standard.
This is a link to a document that gives a general guide to this standard If you are interested in this topic, its pretty in depth and for the most part I'm self taught in this area.
https://electricaltestingcompany.com.au/electromedical/
Here are a few key definitions:
Cardiac-protected electrical area: where the procedure involves direct connection to the
heart, RCD or isolation transformer protection, similar to that required for a body-protected electrical
area, is supplemented with special earthing facilities to also provide protection against ‘microshock electrocution’. Such a system not only protects against any fault or leakage currents posing a macroshock hazard, but also reduces the potential difference appearing between any conducting surfaces in the vicinity of the patient (electrically-operated equipment, plumbing, structural metal and similar) to a level well below that which would produce microshock electrocution
Definition of Equipotential Bonding from AS/NZS 3000:
Electrical connections intended to bring exposed conductive parts or extraneous conductive parts
to the same or approximately the same potential, but not intended to carry current in normal service. Exposed conductive part: a conductive part of electrical equipment that can be touched with the standard test finger, and is not a live part but can become live if basic insulation fails. (exceptions apply, including double insulation, refer AS/NZS 3000 for the complete definition)
Extraneous conductive part: a conductive part that does not form part of an electrical installation but that may be at the electrical potential of a local earth. Examples include the following –
(a) Metal waste, water or gas pipe from outside.
(b) Cooling or heating system parts.
(c) Metal or reinforced concrete building components.
(d) Steel-framed structure.
(There are further examples refer AS/NZS 3000 for the complete definition)
A few key clauses related to this video.
CL.4.4.2.10 – (cardiac bonding) The earth resistance between the EP test terminal and the EP junction or node shall have a maximum value of 0.01Ω.
CL.4.4.2.4.2 – (cardiac bonding) Socket-outlet protective earthing conductors shall be insulated from other conductive items except at the EP junction. The resistance between the socket earth pin and the EP test point or node shall not exceed 0.1 ohm.
CL.4.4.2.5.3 – (cardiac bonding) A separate earthing conductor shall be used to connect each item of permanently wired electrical equipment to the EP junction or node. Permanently wired electrical equipment includes such items as electrical wall boxes, medical service panels, pendants and pedestals, metal cable
enclosures.
CL.4.4.2.5.5 – (cardiac bonding) The resistance of any earthing conductor installed between any socket outlet or any item of permanently wired electrical equipment and the EPJ or node shall not exceed 0.1Ω.
Note: Permanently installed electrical equipment that is inaccessible in the patient environment need not comply, this equipment may be earthed directly to the distribution board.
CL.4.4.2.6 – (cardiac bonding) Permanently installed non-electrical conductive equipment and fittings that contact structural metal shall be connected to the EPJ or node via individual earthing conductors having a resistance not exceeding 0.1 ohms.
• Medical gas outlet reticulated pipelines may be earthed via pipe cable clamps or a braised copper strap with a cable lug connection.
• Water and drainage reticulated pipelines may be earthed via pipe cable clamps.
• Window frames may be earthed via the underlying fixed metal frame that contacts the structural
metal.
• Air conditioning grills may be earthed via the underlying fixed metal frame that contacts the structural metal.
• Monitor brackets, hand and equipment rails etc. may be earthed via the underlying metal wall frame that contacts structural metal. Non-electrical conductive fittings are regarded as contacting structural metal if the resistance to theEPJ or node is less than 1 MΩ when measured at 500V DC (megger test.)
#electrician #construction #sparky
Enjoy pop-Chinas top 40 hits in the background too haha
#electrician #commercialelectrician #sparky
@jointechcabling9103 Shoutout to my fellow bearded sparky whom I absorbed this tip from - check his channel out for some big boy termination tips/beer reviews yeew
#electrician #sparky #milwaukeetools
#electrician #construction #sparky
I've passed the meter on to my 2nd year apprentice - He's a young Dad and kids are bloody expensive hah!
Thanks again to Kaiweets!
What do you think is missing in my loadout?
#electrician #industrial #breakdown
#electrician
#construction
#vlog
The elements can be manually turned on and off via the HMI panel touchscreen, simply a matter of forcing them on and checking the current draw on the feeds
#electrician #industrial #breakdown