BoardRevIn this video, we tackle a completely dead HP ZBook 17 G3 (Motherboard LA-C391P) that was stuck in a frustrating power loop. The board was drawing a 70mA spike and instantly dropping to zero.
Initially, it looked like a classic main rail short or a bad charging IC. I had 0V after the first MOSFET, the Embedded Controller (EC) was pulsing on the thermal camera, and the BQ24780 was rapidly pulsing the MOSFET gates. However, even after replacing the BQ chip and the first two MOSFETs, the exact same fault remained!
Using the oscilloscope, I captured the exact moment the BQ chip aborts the power sequence. It turns out, there was no short circuit! The brand-new replacement MOSFETs had a lower internal gate capacitance than the factory originals. They were turning on too fast, causing a massive inrush current spike that tricked the BQ24780 into thinking there was a short circuit, throwing it into a continuous protection "hiccup" loop.
To fix it, we modified the factory RC snubber circuit by adding a larger capacitor between the Gate and Source of the first MOSFET. This slowed down the gate charge, eliminated the inrush spike, and brought this massive workstation back to life!
Replaced the BQ24780 & MOSFETs, Still No Power? The Hidden Fake Short Loop!BoardRev2026-03-18 | In this video, we tackle a completely dead HP ZBook 17 G3 (Motherboard LA-C391P) that was stuck in a frustrating power loop. The board was drawing a 70mA spike and instantly dropping to zero.
Initially, it looked like a classic main rail short or a bad charging IC. I had 0V after the first MOSFET, the Embedded Controller (EC) was pulsing on the thermal camera, and the BQ24780 was rapidly pulsing the MOSFET gates. However, even after replacing the BQ chip and the first two MOSFETs, the exact same fault remained!
Using the oscilloscope, I captured the exact moment the BQ chip aborts the power sequence. It turns out, there was no short circuit! The brand-new replacement MOSFETs had a lower internal gate capacitance than the factory originals. They were turning on too fast, causing a massive inrush current spike that tricked the BQ24780 into thinking there was a short circuit, throwing it into a continuous protection "hiccup" loop.
To fix it, we modified the factory RC snubber circuit by adding a larger capacitor between the Gate and Source of the first MOSFET. This slowed down the gate charge, eliminated the inrush spike, and brought this massive workstation back to life!
#RightToRepair #BoardRepair #LaptopRepair #Electronics #Oscilloscope #BQ24780 #MotherboardRepair #Soldering #HPZBook #TechTroubleshootingLive Laptop RepairsBoardRev2026-08-08 | Join the Chat! Sessions & A.M.A.iPhone 16 Pro Max Dead Baseband after Charging FailureBoardRev2026-08-08 | A dead Baseband CPU usually means an iPhone is unrepairable—until now. In this video, we work on an iPhone 16 Pro Max with no modem firmware and a dead BB CPU resulting from a charging circuit failure. Every repair tech knows this as a "No Fix" scenario, but today, we're trying a crazy workaround that actually brings the cellular signal back to life!
The Backstory & Repair Summary: This iPhone 16 Pro Max originally came in with charging issues (bad ACE / USB PD controller). After fixing the charging circuit, the phone still had no modem firmware. After ruling out a board interposer connection issue, I moved to the Baseband PMU power supply stage.
By injecting 1.2V into the GPIO_SEQ_PMU_TO_BBPMU_RESET_L line, I noticed a 230mA draw (normal is 30-40mA). Thermal imaging pointed to a short on the PP_3V1_LDO10 line, leading straight into the paired Baseband CPU. Since the BB CPU is paired to the Main CPU, replacing it isn't an option. So, I tried something experimental: removing the BB PMU, masking the shorted pad with UV solder mask on both the board and the chip, and reballing it with a missing ball.
The result? The phone activates, reads the SIM, and makes calls perfectly! While I might not be the first technician to ever encounter this, this video serves as the first fully documented repair and step-by-step instruction available online for bypassing this fatal short.
👇 NEED A REPAIR? SEND IT IN! 👇 We specialize in data recovery and board-level micro-soldering. If you have a dead device, we can help. Start your mail-in repair here: https://www.aacservices.ro Or email us at: service@aacservices.ro
🛠️ TOOLS & GEAR I USE: (Using these affiliate links helps support the channel at no extra cost to you!) * Microscope: https://eleshop.eu/inspection/microscopes/szm7045xt-stl2.html * Soldering Station: https://eleshop.eu/fnirsi-dws-200-f-soldering-station.html * Hot Air Station: https://eleshop.eu/atten-st-862d-hot-air-soldering-station.html * iPhone Interposer Reballing Stencil: AMAOE * Bench Power Supply: Owon P4305 ( https://eleshop.eu/owon-p4305-programmable-lab-supply.html ), Keysight E36103A, Agilent E3632A * Bench Multimeter: Siglent SDM3045X ( https://eleshop.eu/siglent-sdm3045x.html?utm_source=affiliate&utm_medium=website&utm_campaign=BoardRev ), Agilent 34401A, Owon XDM 1041 ( https://eleshop.eu/owon-xdm1041-multimeter.html ) * Oscilloscope: Rigol DHO804 ( https://eleshop.eu/rigol-dho804-oscilloscope.html ) * Front camera: ObsBot Tiny SE * Top camera: Canon EOS M100 * Audio Interface: Vocaster Two
#Microsoldering #RightToRepair #iPhone16ProMax #BoardRepair #TechRepair #AppleRepairLive Diagnostic: iPhone 16 Pro Charging Faults (Oscilloscope Deep Dive)BoardRev2026-08-03 | We are going LIVE to tackle a dead iPhone 16 Pro with a mysterious charging fault. We are bringing out the oscilloscope to track down the exact signal failure.
I will be explaining my entire diagnostic process in real-time, and I'll be answering your questions in the chat!
Going live Sunday the 2'nd of August at: 📍 19:00 EEST (Romania) 📍 17:00 BST (UK) 📍 12:00 PM EDT (US East Coast) 📍 9:00 AM PDT (US West Coast)
👇 NEED A REPAIR? SEND IT IN! 👇 We specialize in data recovery and board-level micro-soldering. If you have a dead device, we can help. Start your mail-in repair here: https://www.aacservices.ro Or email us at: service@aacservices.ro
🛠️ TOOLS & GEAR I USE: (Using these affiliate links helps support the channel at no extra cost to you!) * Microscope: https://eleshop.eu/inspection/microscopes/szm7045xt-stl2.html * Soldering Station: https://eleshop.eu/fnirsi-dws-200-f-soldering-station.html * Hot Air Station: https://eleshop.eu/atten-st-862d-hot-air-soldering-station.html * iPhone Interposer Reballing Stencil: AMAOE * Bench Power Supply: Owon P4305 ( https://eleshop.eu/owon-p4305-programmable-lab-supply.html ), Keysight E36103A, Agilent E3632A * Bench Multimeter: Siglent SDM3045X ( https://eleshop.eu/siglent-sdm3045x.html?utm_source=affiliate&utm_medium=website&utm_campaign=BoardRev ), Agilent 34401A, Owon XDM 1041 ( https://eleshop.eu/owon-xdm1041-multimeter.html ) * Oscilloscope: Rigol DHO804 ( https://eleshop.eu/rigol-dho804-oscilloscope.html ) * Front camera: ObsBot Tiny SE * Top camera: Canon EOS M100 * Audio Interface: Vocaster Two
#iPhone16Pro #Microsoldering #Oscilloscope #MotherboardRepairMacBook Air M1 (A2337) Dead / No Power Fix — 5V 480mA Short Found!BoardRev2026-07-30 | In this video, we tackle a completely dead M1 MacBook Air (A2337) that won't turn on or charge. Plugging in the USB-C meter showed it was stuck at 5V and pulling a constant 480mA — a classic sign that a short circuit is dragging the system down.
After verifying that the PP3v8_AON line was healthy, I pulled out the thermal camera to see what was getting hot. The culprit wasn't actually on the logic board itself! A quick process of elimination led us to the trackpad, where a single glowing capacitor was keeping the entire MacBook from booting. Watch how we isolate the short, remove the bad component, and bring this M1 Mac back to life.
👇 NEED A REPAIR? SEND IT IN! 👇 We specialize in data recovery and board-level micro-soldering. If you have a dead device, we can help. Start your mail-in repair here: https://www.aacservices.ro Or email us at: service@aacservices.ro
🛠️ TOOLS & GEAR I USE: (Using these affiliate links helps support the channel at no extra cost to you!) * Microscope: https://eleshop.eu/inspection/microscopes/szm7045xt-stl2.html * Soldering Station: https://eleshop.eu/fnirsi-dws-200-f-soldering-station.html * Hot Air Station: https://eleshop.eu/atten-st-862d-hot-air-soldering-station.html * iPhone Interposer Reballing Stencil: AMAOE * Bench Power Supply: Owon P4305 ( https://eleshop.eu/owon-p4305-programmable-lab-supply.html ), Keysight E36103A, Agilent E3632A * Bench Multimeter: Siglent SDM3045X ( https://eleshop.eu/siglent-sdm3045x.html?utm_source=affiliate&utm_medium=website&utm_campaign=BoardRev ), Agilent 34401A, Owon XDM 1041 ( https://eleshop.eu/owon-xdm1041-multimeter.html ) * Oscilloscope: Rigol DHO804 ( https://eleshop.eu/rigol-dho804-oscilloscope.html ) * Front camera: ObsBot Tiny SE * Top camera: Canon EOS M100 * Audio Interface: Vocaster Two
#MacBookRepair #RightToRepair #A2337 #AppleSilicon #Microsoldering #TechRepair #ThermalCameraAnother one today? iPhone 15 PRO no power, no chargeBoardRev2026-07-26 | Join the Chat! Sessions & A.M.A.Live Board Repair 25-07-2026BoardRev2026-07-26 | Join the Chat! Sessions & A.M.A.Stop Replacing Random Chips! iPhone 16 Pro Charging Repair & Oscilloscope Signal TestBoardRev2026-07-23 | Stop replacing every chip on the board! In this video, we go deep into the iPhone 16 Pro charging circuit architecture to show you how to properly diagnose charging faults step-by-step instead of shotgunning chips like ACE, Parrot, ROM, and U4000.
🔧 WHAT WE COVER IN THIS REPAIR: • DC Power Supply test: Detecting off-state current leakage (9mA draw when off). • Diode mode measurement: Identifying low diode readings on the VBUS_E85 line. • Isolating the short: Finding the shorted PP_Charger_LDO_internal rail pointing directly to U4000. • BGA Rework: Replacing the U4000 Charging IC to restore full fast-charging. • Scope Analysis: Real-time oscilloscope test of the U9500 (ACE PD Controller) communication line (IO_ACE_TO_CHARGER_VBUS1_VALID_3V3) to prove how the charger handoff signal actually works.
👇 NEED A REPAIR? SEND IT IN! 👇 We specialize in data recovery and board-level micro-soldering. If you have a dead device, we can help. Start your mail-in repair here: https://www.aacservices.ro Or email us at: service@aacservices.ro
🛠️ TOOLS & GEAR I USE: (Using these affiliate links helps support the channel at no extra cost to you!) * Microscope: https://eleshop.eu/inspection/microscopes/szm7045xt-stl2.html * Soldering Station: https://eleshop.eu/fnirsi-dws-200-f-soldering-station.html * Hot Air Station: https://eleshop.eu/atten-st-862d-hot-air-soldering-station.html * iPhone Interposer Reballing Stencil: AMAOE * Bench Power Supply: Owon P4305 ( https://eleshop.eu/owon-p4305-programmable-lab-supply.html ), Keysight E36103A, Agilent E3632A * Bench Multimeter: Siglent SDM3045X ( https://eleshop.eu/siglent-sdm3045x.html?utm_source=affiliate&utm_medium=website&utm_campaign=BoardRev ), Agilent 34401A, Owon XDM 1041 ( https://eleshop.eu/owon-xdm1041-multimeter.html ) * Oscilloscope: Rigol DHO804 ( https://eleshop.eu/rigol-dho804-oscilloscope.html ) * Front camera: ObsBot Tiny SE * Top camera: Canon EOS M100 * Audio Interface: Vocaster Two
#iPhone16Pro #MicroSoldering #iPhoneRepair #BoardLevelRepair #ElectronicsRepair #Oscilloscope #iPhoneDiagnosticiPhone 15 Pro No IMEI / Wont Activate? Motherboard Split & Reballing GuideBoardRev2026-07-09 | You asked for it, and here it is! In this highly requested video, I walk you through the entire process of splitting, diagnosing, reballing, and soldering an iPhone motherboard back together.
Today on the bench, we have an iPhone 15 Pro that refused to activate. Checking the device info revealed a missing IMEI and EID—only the serial number was showing. This points straight to a baseband CPU issue, but is it a power failure or a broken interposer connection?
Watch as I break down the exact diagnostic steps to find the root cause. I’ll show you how to rule out a power delivery issue using two bench power supplies to inject 1.2V directly to the baseband PMU enable signal. Once we confirm the PMU is pulling a healthy 30mA, we know the issue lies in the interposer.
From there, we split the boards, prep and clean the pads, and dive into the boardview. I also explain a crucial diagnostic trick: how to properly measure PCIe communication lines between the baseband and main CPU that show up as "OL" on your multimeter due to series capacitors. Finally, we reball the board, solder it back together, and perform a 3uTools restore to bring the cellular data back to life!
👇 NEED A REPAIR? SEND IT IN! 👇 We specialize in data recovery and board-level micro-soldering. If you have a dead device, we can help. Start your mail-in repair here: https://www.aacservices.ro Or email us at: service@aacservices.ro
🛠️ TOOLS & GEAR I USE: (Using these affiliate links helps support the channel at no extra cost to you!) * Microscope: https://eleshop.eu/inspection/microscopes/szm7045xt-stl2.html * Soldering Station: https://eleshop.eu/fnirsi-dws-200-f-soldering-station.html * Hot Air Station: https://eleshop.eu/atten-st-862d-hot-air-soldering-station.html * iPhone Interposer Reballing Stencil: AMAOE * Bench Power Supply: Owon P4305 ( https://eleshop.eu/owon-p4305-programmable-lab-supply.html ), Keysight E36103A, Agilent E3632A * Bench Multimeter: Siglent SDM3045X ( https://eleshop.eu/siglent-sdm3045x.html?utm_source=affiliate&utm_medium=website&utm_campaign=BoardRev ), Agilent 34401A, Owon XDM 1041 ( https://eleshop.eu/owon-xdm1041-multimeter.html ) * Oscilloscope: Rigol DHO804 ( https://eleshop.eu/rigol-dho804-oscilloscope.html ) * Front camera: ObsBot Tiny SE * Top camera: Canon EOS M100 * Audio Interface: Vocaster Two
💬 Got a repair question? Drop a comment below! If you found this deep-dive helpful, please hit the Like button and Subscribe for more advanced microsoldering tutorials and motherboard repairs.
Hashtags: #Microsoldering #iPhone15Pro #MotherboardRepair #RightToRepair #AppleRepair #BoardReballing #BasebandRepair #TechRepairHidden Water Damage Killed this iPhone 16 Pro Max (Bootloop Fix!)BoardRev2026-07-08 | Hidden liquid damage almost sent this iPhone 16 Pro Max to the graveyard. Here is how I tracked down a mysterious 5mA draw and brought it back to life.
This iPhone 16 Pro Max came into the shop stuck in recovery mode, but the symptoms were all over the place. On the bench power supply, it would sometimes bootloop, sometimes hit restore mode, and other times just randomly reboot. The only solid clue? A weird 5mA power draw before even prompting the phone to boot, and a triggered red Liquid Damage Indicator (LDI) — even though the board looked spotless under the microscope.
In this video, I split the motherboard sandwich to find the real culprit: hidden corrosion between the top board and the interposer.
🔧 The Repair Process:
Diagnosing the inconsistent bootloop & 5mA draw
Splitting the iPhone 16 Pro Max motherboard
Discovering hidden corrosion on the interposer
Micro-soldering & rebuilding traces (VCC_Batt, VDD_Boost, and VDD_Main)
Curing with UV solder mask
Reballing the interposer and rejoining the boards
If you enjoy deep-dive micro-soldering repairs and board-level diagnostics, hit the Like button and Subscribe for more!
👇 NEED A REPAIR? SEND IT IN! 👇 We specialize in data recovery and board-level micro-soldering. If you have a dead device, we can help. Start your mail-in repair here: https://www.aacservices.ro Or email us at: service@aacservices.ro
🛠️ TOOLS & GEAR I USE: (Using these affiliate links helps support the channel at no extra cost to you!) * Microscope: https://eleshop.eu/inspection/microscopes/szm7045xt-stl2.html * Soldering Station: https://eleshop.eu/fnirsi-dws-200-f-soldering-station.html * Hot Air Station: https://eleshop.eu/atten-st-862d-hot-air-soldering-station.html * iPhone Interposer Reballing Stencil: AMAOE * Bench Power Supply: Owon P4305 ( https://eleshop.eu/owon-p4305-programmable-lab-supply.html ), Keysight E36103A, Agilent E3632A * Bench Multimeter: Siglent SDM3045X ( https://eleshop.eu/siglent-sdm3045x.html?utm_source=affiliate&utm_medium=website&utm_campaign=BoardRev ), Agilent 34401A, Owon XDM 1041 ( https://eleshop.eu/owon-xdm1041-multimeter.html ) * Oscilloscope: Rigol DHO804 ( https://eleshop.eu/rigol-dho804-oscilloscope.html ) * Front camera: ObsBot Tiny SE * Top camera: Canon EOS M100 * Audio Interface: Vocaster Two
#iPhone16ProMax #MicroSoldering #PhoneRepair #RightToRepair #TechRepair #DataRecovery #MotherboardRepairiPhone 15 Pro Max No Boot: Stuck at 170mA! Mysterious NAND Repair FixedBoardRev2026-07-07 | Welcome back to the lab! In today's video, we tackle a challenging repair on an iPhone 15 Pro Max.
This phone was sent over from another repair shop, where it was diagnosed with "No Display." However, a quick check on the lab power supply revealed a completely different story. The device wasn't actually booting at all; it was instantly stuck drawing a flat 170mA immediately after prompt-to-boot.
This symptom immediately points to critical communication issues, most likely with the NAND (storage). Normally, I would proceed by investigating the NAND power lines and the NAND PCIe communication lines.
But something about this board felt off. Under the microscope, we found the NAND in a visually "pristine" condition, almost like a factory refurbishment, yet the surrounding components told a different story. We discovered tiny solder balls that suggested significant heat, a different underfill color, and a complete lack of underfill near the adjacent shield.
In this video, I take you through my unique troubleshooting process and the decision to forgo testing and jump straight into a reball.
Watch as we:
- Identify the true boot failure symptom (stuck at 170mA). - Perform a visual inspection under the microscope and spot the clues of a prior rework. - Carefully remove, reball, and resolder the NAND.
Ultimately, bring this iPhone 15 Pro Max back to life!
This repair is a perfect example of why you must trust your eyes and experience over simple "No Display" claims. Let me know in the comments if you've encountered similar "factory-refurbished" style issues.
Don't forget to Like, Share, and Subscribe for more professional micro-soldering and logic board repairs!
Disclaimer: Micro-soldering and logic board repair should only be performed by trained professionals. Proceed with caution and at your own risk. This video is for informational purposes only.
#iphone15promax #nandrepair #phonerepair #microsoldering #no boot #stuckat170ma #logicboardrepair #techrepairDell G15 Liquid Damage: Finding the HIDDEN Fault Killing the CPU!BoardRev2026-07-05 | This Dell G15 was sent over by some good friends at a neighboring repair shop. They did a great job with the initial heavy cleanup after a major liquid spill, but the CPU was still stubbornly refusing to power on, so we teamed up to track down the final hidden faults... Finding the correct boardview was the biggest challenge for this specific model, but once I had it, the solution was clear. We were dealing with three heavily corroded resistors that were preventing the CPU from receiving its power. This repair was not just about changing those components, though. We also had to fix the LCD backlight line, which had a corroded fuse and a damaged track.
Watch as we diagnose the failing phases and use a thermal camera to confirm the CPU is finally 'alive' after the component-level repairs! This video highlights the importance of thorough trace-level diagnostics, not just a simple visual cleanup.
#DellG15 #LaptopRepair #MotherboardRepair #LiquidDamage #CPURepair #ElectronicsRepair #RepairTech #ThermalCameraiPhone 14 Pro Max No Touch: Oscilloscope vs. Diode Mode (Finding the Hidden Short!)BoardRev2026-07-04 | Today's repair is a tricky case: an iPhone 14 Pro Max from another shop, completely non-responsive to touch. I started with a standard diode mode measurement on the board display connector, and surprisingly, everything compared perfectly to my boardview reference. This ruled out obvious line failures and guided me deeper into the circuit logic.
I shifted my focus to the power rail integrity. Using an oscilloscope set in ROLL mode, I probed the 1.24V touch voltage line first; it was solid and stable. Next, I checked the 5.1V touch voltage line, and that's where the problem appeared: a incredibly dirty, noisy signal on the scope!
Consulting the schematic, I found the source: a dedicated power IC that boosts the 4.1V vdd_main line to 5.42V for its own internal use, and then feeds an internal LDO regulator to output the clean 5.1V touch voltage. I successfully triggered the circuit without fully powering the phone by injecting an enable signal to this chip while keeping the battery connected. Probing the 5.1V line, I confirmed only noise was being produced.
By comparison with a known-good donor board, I confirmed the chip should produce a clean 5.1V upon enable. This narrowed the short to the internal 5.42V boost rail. Separating the boards, I located and replaced a tiny, shorted capacitor on that internal 5.42V line. With the new cap in place, the 5.1V touch line came alive with a clean signal, and the phone's touch was fully restored.
This repair highlights why diode mode is not enough for active circuit failure diagnosis. Learn how to use a scope for complex voltage rail analysis and see the difference!
#iPhone14ProMaxRepair #NoTouchFix #MicroSoldering #iPhoneDiagnostic #OscilloscopeRepair #PhoneRepairCommunityLenovo IdeaPad 330 No Power: Hunting a Short Circuit!BoardRev2026-06-29 | In this video, we tackle a completely dead Lenovo IdeaPad 330 laptop that isn't reacting to the charger or the power button. Watch step-by-step as we tear it down, diagnose the motherboard, and track down a hidden short circuit on the main power rail using a multimeter and a thermal camera!
If you love electronics repair, board-level diagnostics, and satisfying fixes, make sure to like, comment, and subscribe!
🛠️ TOOLS USED IN THIS VIDEO: • Multimeter: Siglent SDM3045X • Thermal Camera: InfiRay P2 PRO • DC Power Supply: Keysight E36103A • Soldering Iron/Hot Air Station: FNIRSI DWS200 / Atten ST-862 • Microscope: NoName :)
💬 Got questions about this repair? Drop a comment below and I'll do my best to answer!
#LenovoRepair #LaptopRepair #ElectronicsRepair #BoardRepair #ShortCircuit #LenovoIdeaPad #HowToFix #ThermalCameraiPhone 15 Pro White Screen FixBoardRev2026-06-28 | In today's repair, we tackle an iPhone 15 Pro suffering from the "White Screen of Death." When booting up, the device powered on but only showed a blank white display.
Watch as we walk through the step-by-step diagnostic process to find the hidden logic board issue.
🔧 In this video, we cover:
Initial Testing: Checking for abnormal power consumption on the DC power supply (which tested perfectly fine).
Diode Mode Diagnostics: Probing the display connector to find the culprit.
Finding the Fault: Locating the PP1V8_TOUCH_DISPLAY_DVDD_S2_CONN line, which was giving fluctuating diode mode readings (0.6V to 1.3V instead of the normal 0.3V).
The Fix: Identifying the blown filter on this line and using a quick solder blob bridge to bypass it. This method perfectly restores functionality while avoiding unnecessary heat stress on the logic board!
If this video helped you fix your device or learn something new about microsoldering, please hit the Like button and Subscribe for more deep-dive tech repairs!
#iPhone15Pro #Microsoldering #RightToRepair #LogicBoardRepair #iPhoneRepair #TechRepair #WhiteScreenFix #SolderingiPhone 15 Pro Dead / Wont Turn On - VDD_Boost Short RepairBoardRev2026-06-27 | In this video, we tackle a completely dead iPhone 15 Pro that wouldn't charge or power on. Initial USB-C ammeter readings showed it pulling 5V with brief 78mA pulses, indicating the ACE chip was likely good, but pointing straight to a main line short.
By injecting voltage directly into the battery connector, we found a massive 5-Amp current draw. Watch as we use a thermal camera to track the heat, split the sandwich motherboard, and hunt down the exact shorted capacitor and IC on the VDD_Boost line!
#iPhone15Pro #Microsoldering #RightToRepair #AppleRepair #MotherboardRepair #TechRepair #LogicBoard #ThermalCamera #VDDBoost #ElectronicsRepairiPhone 15 Dead (5V 3mA): Why I Ignored the ACE Chip + Oscilloscope ProofBoardRev2026-06-22 | In this video, we tackle an iPhone 15 that came into the shop completely dead, pulling a flat 5V and 3mA on the USB-C amp meter. Instead of blindly swapping components, we walk through a logical, step-by-step board-level diagnostic to isolate the exact cause of the failure.
🔧 What you’ll learn in this repair:
- The Initial Triage: Powering the board via DC power supply to check boot consumption. - Ruling out the ACE PD Controller: Why normal boot current (under 100mA initially) and functional touch strongly indicate the ACE chip is perfectly fine, despite the 5V/3mA USB-C reading. - Finding the Fault: Injecting 5V into the VBUS_E85 line, checking the ACE internal LDOs (3.3V), and catching the culprit: a charging IC with internal LDOs pushing 5V instead of the required 3.3V. - Oscilloscope Deep Dive: After replacing the charging IC, we hook up the oscilloscope to visualize exactly how the iPhone talks to the charger. We probe the CC line to see the PD communication and monitor the IO_ACE_TO_CHARGER_VBUS1_VALID_L_HV line to catch the precise impulse the ACE chip sends to the charging IC to initiate charging.
If you are into microsoldering, board-level diagnostics, and understanding how the circuits actually communicate, this deep dive is for you!
#iPhone15Repair #Microsoldering #RightToRepair #BoardLevelRepair #Oscilloscope #ChargingIC #AppleRepair #LogicBoardRepair #TechRepair #ElectronicsDiagnosisLenovo Legion 5 Black Screen Fix | No Display & No HDMI (Motherboard Repair)BoardRev2026-06-20 | Got a Lenovo Legion 5 that powers on with a black screen, no HDMI output, but a working Caps Lock light? In this component-level repair, we track down exactly what causes this frustrating issue. The responsive Caps Lock key told us the CPU and RAM were passing POST, isolating the issue to the GPU or display circuit. After measuring the power rails, I discovered the GPU phases were missing power. A deep dive into the driver's datasheet revealed a missing VCC voltage, leading us straight to a dead short on the +5VS line and a blown switch IC hidden on the other side of the board.
⚠️ Note on the repair: In this video, I use a wire jumper to bridge the +3ALW/+5ALW lines to the +3VS/+5VS lines. This is a brilliant diagnostic step to confirm the fix, but for a permanent repair, always replace the switch IC! Leaving it jumpered will cause parasitic battery drain and bypass the board's built-in power protection.
🔔 Subscribe for more deep-dive motherboard repairs! 👍 If this video helped you diagnose your board, please drop a like. 💬 Let me know down in the comments if you've run into a similar issue on the Legion series.
#LenovoLegion #LaptopRepair #MotherboardRepair #ComponentLevelRepair #ElectronicsRepair #RightToRepair #TechRepairiPhone 17 Pro No Power Diagnostics: VDD_Main Short Repair & Board Power MasterclassBoardRev2026-06-19 | This iPhone 17 Pro came in completely dead from another repair shop—no power and no charging. After connecting it to a USB-C meter, we noticed 5V with 0A consumption and occasional 535mA peaks, instantly pointing us toward a board-level short.
In this video, I walk you through the entire diagnostic and repair process. We confirm the VDD_Main short using diode mode and lab PSU injection, map out the potential culprits using the boardview, and do a deep dive into the iPhone 17 Pro’s power and charging architecture. We also take a few minutes to compare the repairability of the 17 series to the 16 series—specifically looking at the sandwiched charging IC and USB-C PD controller (ACE) which makes this generation a bit trickier to work on!
Luckily, we managed to track down a shorted capacitor near the underfilled PMIC using a thermal camera, completely avoiding the need to split the logic boards.
🛠️ Tools & Techniques Used:
USB-C Ammeter Diagnostics Multimeter Diode Mode Testing Lab PSU Voltage Injection (0.8V) Thermal Camera Short Detection Boardview Analysis Cold Shield Removal (No Hot Air)
⏳ Video Chapters: 0:00 - Intro & Device History 0:43 - USB-C Diagnostics: Voltage & Current Draw 02:39 - Diode Mode Testing: Checking the Battery Connector 03:00 - Lab PSU Injection: Confirming the Short 03:33 - Diode Mode Testing: Finding the Dead Short on VDD_Main 04:00 - Boardview Analysis: Hunting the Culprit 07:21 - Thermal Camera Injection: Searching for Hidden Heat 12:39 - iPhone 17 Pro Power Circuit Breakdown (vs. iPhone 16) 19:50 - Shield Removal (No Hot Air Method) 25:52 - Thermal Camera Success: Locating the Shorted PMIC Cap 29:09 - Final Test: Booting & Charging Restored!
Note: Because the main PMIC is underfilled, the shorted capacitor was removed but not replaced to avoid unnecessary thermal stress on the PMIC and the surrounding board.
Don't forget to like, subscribe, and drop any questions down in the comments!
#iPhone17Pro #Microsoldering #RightToRepair #LogicBoardRepair #VDDMain #TechRepair #AppleRepairDead iPhone 16 Pro FIXED! You Wont Believe What Caused It...BoardRev2026-06-10 | In today's repair, we are tackling an iPhone 16 Pro that came in completely dead and unresponsive. If you're dealing with a device that won't boot, this video walks you through the step-by-step diagnostic process to find the exact component causing the failure! When plugging the phone into the USB power meter, it was stuck at 5V and cycling between 0A and 1A without negotiating 15V fast charging. This is a classic sign of a short circuit. To dig deeper, I connected the logic board to a lab DC power supply via the battery connector. Pressing the power button immediately caused a 1 Amp current draw after just one second—a dead giveaway that we had a short on a secondary/auxiliary power line, not the main VDD_MAIN. Using a thermal camera, the culprit lit up almost instantly. We identified a glowing hot, shorted capacitor right next to the display connector on the PP3V15_Touch_Display_S2 line. After carefully removing the shorted cap, the short was cleared, and the phone booted up perfectly!
#iPhone16Pro #Microsoldering #RightToRepair #PhoneRepair #ThermalCamera #ShortCircuit #AppleRepair #LogicBoardRepair #PP3V15iPhone 15 Pro Max No Service Fix: Complete eSIM Chip ReplacementBoardRev2026-06-09 | Got an iPhone 15 Pro Max stuck on "No Service"? You're not alone. One of the most common issues on the iPhone 15 series is a failing or corrupted eSIM chip, which completely disables your physical SIM card reader as well! In this video, I take you through the entire 40-minute process of diagnosing and fixing this exact issue.
Watch over my shoulder as I unbox a customer's device, run the initial diagnostic tests, register it in my shop's system, and take it straight to the microscope. I'll show you step-by-step how to remove the dead eSIM chip and replace it with a donor chip to restore the physical SIM functionality.
⚠️ Note: While this repair brings the physical SIM card reader back to life and saves the phone, the eSIM functionality cannot be registered again due to security pairing.
#iPhone15ProMax #NoService #LogicBoardRepair #MicroSoldering #eSIM #AppleRepair #TechRepair #RightToRepair #iPhoneRepairFixing a Dead iPhone 16 Pro Max: Multi-Chip Nightmare (Shorts + ROM Hack)BoardRev2026-06-08 | This was a tough one! This dead iPhone 16 Pro Max came in showing no power and no charge, only drawing a flat 125mA from the charger. My diagnostic process led me through multiple chip failures, unexpected shorts, and a tricky firmware hurdle.
Initial diode mode measurements on the Vbus and CC lines seemed fine. I had to remove the main board and cut the shields covering the ACE and Charging ICs to go deeper. Probing the power lines around the ACE chip, I found its internal 3v3 LDO was shorted. The charging IC was also abnormally warm.
I replaced both chips with parts from a donor board, hoping it would be a simple fix. But it wasn't! A mystery 125mA current draw remained, even with the phone off. Thermal imaging revealed the 'Austin chip' (the component for camera autofocus power on the schematic) was heating up. A shorted capacitor on its 6V output was only half the problem. The chip itself was damaged too. After replacing the cap and the Austin chip, the current draw was finally gone.
But my troubles weren't over! The phone powered on, but it would only negotiate 5V at 450mA – a clear sign of ACE ROM mismatch. My attempts to flash the phone and preserve data via 3uTools failed, trapping the phone in recovery/DFU mode.
The final fix? I had to get serious. I pulled the bin file from the donor ACE chip's ROM using a CH341A programmer and jumper wires, then successfully wrote that clean dump to the target board's ROM. Once the correct ROM data was present, the phone restored successfully and fully restored 15V PD charging.
Watch the full, detailed step-by-step micro-soldering and diagnostic process to see exactly how I brought this advanced device back from the dead.
#iPhone16ProMax #MicroSoldering #PhoneRepair #NoPowerRepair #iPhoneRepair #ACEROM #ComponentLevelRepair #BoardRepair #DeadPhone #CH341AHP Elite Mini 800 G9 Motherboard Repair - 3 Red 4 White Error (Unsolved EC Fault?)BoardRev2026-06-06 | I’m working on an HP Elite Mini 800 G9 that refuses to boot, throwing the dreaded 3 Red / 4 White blink code (Power Adapter Mismatch/Fault). My 120W and 150W power bricks are perfectly fine, so I took this down to the component level to figure out why the board is rejecting the power. This turned into a massive diagnostic rabbit hole, and after a full day of probing, I'm currently stuck. I suspect a defective Embedded Controller (EC) or a failed "Power Good" sequence from a buck converter, but I would love to hear your theories in the comments!
Diagnostic Steps Taken:
The Main Suspect: Traced the ID pin to the AS393M window comparator. The chip is healthy, but the board was dropping the 17V ID signal to 3V, tripping the over-voltage protection.
The Ghost Hunt: Found a 1-second delay on the ID line causing the EC to time out. Removed an LED acting as a leaky capacitor, but the EC still wasn't happy.
Bypassing the EC: Attempted to manually trick the EC by wiring a 29kΩ resistor to ground, bringing the ID pin to 1.2V.
The HP Impedance Trap: Discovered the EC does a 3-second "active load" test, dropping my 1.2V down to 0.9V and triggering the error code anyway. Sweeping the resistance with a potentiometer didn't clear the fault.
The Blast Zone: Briefly injected an Enable signal into the S335A buck converter, which caused it to dump 12V and blow its gate resistor/load switch. I repaired the blast zone, but the main fault remains.
My Conclusion: The main 19.5V rail is rock solid. I believe the S335A controller took internal damage and is failing to send a "Power Good" signal back to the EC within the 3-second watchdog timer, OR the EC itself is internally defective.
If you've tackled the power sequence on these newer HP G9 boards or know the exact threshold for the smart pin impedance test, let me know below!The Domino Effect: Tracing a Fatal Cascading Short on a Lenovo E15 Gen2BoardRev2026-06-03 | In this video we tackle a Lenovo E15 Gen2 that came in completely dead, pulling only 5V and 100mA on the USB-C meter. What started as a visibly blown component quickly turned into a deep dive into tracing a cascading short circuit.
After opening the laptop, I immediately spotted a blown driver for the 5V ALW line. However, simply replacing a burned chip is rarely the end of the story. Join me under the microscope as we use voltage injection and thermal imaging to chase this short down the line - from a heating PD controller, to a shorted Lenovo PMIC, and finally arriving at the ultimate culprit.
While this motherboard ultimately ended up as a "no fix" due to a dead PCH, this video serves as a perfect step-by-step masterclass on how to properly diagnose complex, multi-component failures without just throwing parts at the board.
🔍 Diagnostics Covered in this Video:
- Initial USB-C Meter reading (5V / 100mA) - Identifying and removing the blown 5V ALW driver - Voltage injection (0.8V) and thermal camera fault finding - Tracing a cascading short through the PD Controller and PMIC - Diagnosing a dead short on the 0.75ALW line leading to the PCHWhich Bench Multimeter Should You Buy in 2026? (Siglent SDM3045X Review & €400 Showdown)BoardRev2026-05-29 | If you have €400 to upgrade your repair bench, should you buy a budget meter, a vintage classic, or the modern mid-tier? In this definitive Siglent SDM3045X review and comparison, we put it head-to-head against the Owon XDM1041 and the legendary 6.5-digit HP 34401A.
We are testing speed, compliance voltages, and exposing a frustrating firmware bug in the Siglent. I also show you why old reviews of the Siglent's speed are completely wrong (hint: it's the stock probes!), and why you might want to stop buying vintage multimeters for modern board repair. Finally, if you are a repair streamer or creator, I showcase my custom-built, transparent OBS software that unifies all of these meters perfectly on screen.
Huge thanks to Eleshop for sending the Siglent unit over and supporting the channel! If you are in the EU, they are the absolute best place to upgrade your bench.
🛒 Support the channel by shopping at Eleshop (EU):
Buy the Siglent SDM3045X: https://eleshop.eu/siglent-sdm3045x.html?utm_source=affiliate&utm_medium=website&utm_campaign=BoardRev
Buy the Owon XDM1041: https://eleshop.eu/owon-xdm1041-multimeter.html
Browse Eleshop's Test & Measurement Gear: https://eleshop.eu/
Download my FREE Custom OBS Multimeter Software: https://www.aacservices.ro/aacwebsite/software.html
⏱️ Chapters: 0:00 - The €400 Multimeter Dilemma 1:25 - Siglent SDM3045X Speed Test & Probes 3:40 - Vintage HP vs Modern Siglent: Diode Test 6:02 - I Found a Bug in the Siglent Firmware 7:51 - Build Quality, Screens & Fanless Design 9:13 - The Ultimate OBS Setup (Custom Software) 12:21 - Eleshop Showcase & Final VerdictMacBook Air A2337 M1 Not Charging Fix | Stuck on 5V & No CurrentBoardRev2026-05-28 | Did your M1 MacBook Air (A2337) suddenly stop charging and power off, stuck at 5V with no current draw? In this detailed repair video, we diagnose and fix a common, tricky charging fault on these boards.
My diagnosis path: Symptoms: Laptop is dead, draws zero current from USB-C. USB voltage is stagnant at 5V, failing to negotiate to 20V. Initial Checks: Full board inspection, verified all USB-C port connectors are healthy. Measurement: Found a short circuit on a key 3.3V LDO power line around one of the two CD3217 ACE chips (Thunderbolt/USB controller). Confirmation: Injected 0.8V into the shorted LDO line and used a thermal camera to locate the exact failing component. The CD3217B12 chip lit up immediately.
Repair: Swapped the failing CD3217B12 with a donor chip from a matching board.
See the full process of microscopic soldering and verification of the fix, taking the voltage negotiation back to 20V and restoring charging and power functionality.
Repair Steps Covered:
A2337 M1 Board Disassembly USB-C Port Verification Voltage Injection for Diagnosis CD3217 ACE Chip Swapping (BGA soldering)
Disclaimer: This is a component-level repair demonstrated by a trained professional. Attempting micro-soldering repairs requires specialized tools and expertise. Follow at your own risk.
Make sure to Subscribe and hit the bell for more detailed MacBook repairs! 🛠️
#MacBookRepair #A2337M1 #CD3217 #NotChargingFix #AppleTech #MicrosolderingThey Cleaned the Coffee, but Missed THIS. (Asus TUF FX505D Repair)BoardRev2026-05-26 | This Asus TUF FX505D came in from another repair shop completely dead after a coffee spill. The keyboard backlight would flash for a split second, and then nothing. Let's track down the fault! In this video, we tackle a board-level repair on an Asus TUF FX505D that wouldn't turn on. After verifying the 3.3V and 5V lines were present, I noticed the 1.2V RAM line was dropping out immediately. Because I didn't have the exact connector for my lab bench supply, I improvised: I the Arduino meter we have built together a few days ago to monitor the board's power draw live on screen. The board was pulling about 260mA for a second before dropping back to zero. After pulling the board, I found the culprit: the previous shop missed some sneaky liquid damage near the 0.9V PWM chip. A single corroded resistor with infinite resistance was stopping the whole show. Watch how we use the datasheets and schematics to figure out this weird 72.3kΩ PWM frequency resistor, find a 75kΩ donor, and bring this gaming laptop back to life.
#AsusTUF #LaptopRepair #BoardLevelRepair #ElectronicsRepair #RightToRepair #Arduino #TechRepair #Soldering #MicroSolderingThe Weirdest Asus TUF Repair: Perfect on AC, Dies on Battery (0V Mystery Solved!)BoardRev2026-05-19 | We have a fascinating diagnostic puzzle on the bench today. This Asus TUF FA507 runs flawlessly when plugged into the wall, but the moment you switch to battery power... chaos. Freezes, weird memory Blue Screens (PFN_LIST_CORRUPT), and eventually, the battery completely trips its protection circuit and drops to 0V! In this video, I walk through the complete troubleshooting process. We start by ruling out the usual suspects like Asus Armoury Crate software bugs, bad RAM, and power state driver issues. When flexing the chassis triggered the crash, it was time to pull the board and get the multimeter out. I even went as far as resoldering the battery connector and replacing the BATFET, but the issue persisted. The ultimate fix came down to the golden rule of board repair: isolate your peripherals! Watch how a tiny, seemingly unrelated component was pulling down the whole system and sending the battery's BMS into a panic state.
#AsusTUF #LaptopRepair #MotherboardRepair #RightToRepair #TechRepair #Electronics #BSOD #Diagnostic #FA507 #HardwareRepairCharger Turns Off When Plugged In? Dell Laptop Motherboard RepairBoardRev2026-05-18 | Got a laptop that completely kills your charger's power light the second you plug it in? In today’s repair, we have a dead Dell Latitude E5550 that won't charge or power on. The charger immediately drops into protection mode—a classic sign of a severe short circuit on the motherboard.
Join me at the bench as we take this board out and hunt down the short! I’ll walk you through my diagnostic process:
- Tracing the circuit starting from the DC charging port. - Identifying a blown input MOSFET. - Discovering a dead short to ground right after the first current sense resistor.
Going under the microscope to find the true culprit—a tiny, cracked capacitor hiding in plain sight!
After replacing the shorted cap and dropping in a new MOSFET, this Latitude is fully assembled, charging perfectly, and back from the dead!
#LaptopRepair #DellLatitude #MotherboardRepair #RightToRepair #Soldering #ShortCircuit #MicroSoldering #ElectronicsRepairPowerMeter Graph Line Issue FixedBoardRev2026-05-17 | ...Floating OBS Overlays for Electronics Repair (Transparent Multimeter & Power Supply)BoardRev2026-05-14 | You asked, and I delivered! After showing you my custom multimeter and power supply apps in the last video, the number one request was to make them transparent for OBS.
In this update, I'm thrilled to introduce Streamer Mode. I’ll show you how the new transparent data cards float perfectly over my microscope feed, taking up way less space while still giving you real-time voltage, current, and graphing data. I've updated all three pieces of software (LabMeter, HP34401A app, and the Arduino DIY code) to support this clean new look.
Bonus Segment: Stick around until the end because I’m pulling back the curtain! I’m taking you behind the scenes to show you my personal homelab setup, demonstrating how I use my own GitLab instance and GitLab Runners to automatically deploy the updated AAC Apps website into production.
👇 DOWNLOADS & RESOURCES 👇
Get the Updated AAC Apps Here: https://www.aacservices.ro/aacwebsite/software.html
Don't forget to Like and Subscribe! Let me know in the comments if you prefer the solid backgrounds or the new transparent Streamer Mode!
#ElectronicsRepair #OBSStudio #StreamSetup #Microsoldering #GitLab #DevOps #Homelab #RightToRepairI Made Custom Apps to Put My Lab Gear on OBS (And You Can Download Them!)BoardRev2026-05-13 | Ever wondered how I get those clean, real-time multimeter readings and power supply graphs on the screen during my laptop and phone repairs? In this video, I’m showing you exactly how it’s done!
I've created custom PC applications (AAC Apps LabMeter & AAC Apps HP34401A) that connect directly to your bench equipment and output a beautiful, stream-ready interface perfect for OBS window capture. Whether you have professional gear like an HP/Agilent 34401A or Owon XDM1041, or you want to build your own ultra-cheap digital power supply meter using an Arduino and an INA219/INA260 sensor, I've got you covered.
I'll walk you through how the software looks, how to set it up, and how to program your Arduino from scratch using the Arduino IDE.
👇 DOWNLOADS & RESOURCES 👇
Get the software and Arduino sketch from my website: https://www.aacservices.ro/aacwebsite/software.html
⚙️ HARDWARE MENTIONED IN THIS VIDEO ⚙️
Multimeters: HP/Agilent 34401A, Owon XDM1041
DIY Meter Parts: Arduino (Uno/Nano), INA219 or INA260 Current Sensor Module
Cables: USB to Serial/UART Bridges
Don't forget to Like and Subscribe for more advanced repair tutorials, custom tools, and bench tips! Let me know in the comments if you get this running on your own bench.
#ElectronicsRepair #OBSTutorial #ArduinoProject #BenchGear #RightToRepair #Soldering #TechRepair #DIYElectronicsSamsung Galaxy A16 5G Dead Repair - VBUS Short & OVP Bypass for Data RecoveryBoardRev2026-05-10 | In this video, we tackle a Samsung Galaxy A16 5G that arrived completely dead. It wasn't drawing any current and wouldn't power on.
Diagnostic Process:
Checked the VBUS line and found a direct short to ground.
Traced the short to a physically burned OVP (Over Voltage Protection) chip.
Removed the faulty IC and performed a jumper bypass to restore the power path.
Goal: This was a data recovery mission! By bypassing the protection circuit, we successfully powered the device to retrieve the client's important files.
Disclaimer: Bypassing an OVP is recommended for data recovery purposes. For a permanent, safe repair, always replace the IC with a new one to ensure the phone remains protected against voltage spikes.iPhone 13 Pro Max DEAD - Another Shop Gave Up! (2.3A Short Found)BoardRev2026-05-08 | This iPhone 13 Pro Max came into the lab totally dead, overheating, and previously rejected by another repair shop. As soon as I hooked the battery connector up to the DC power supply, I noticed a massive 2.3A current draw—even without prompting the phone to boot!
Interestingly, measuring the VBAT and VDD_MAIN lines in diode mode showed no dead shorts. So, we brought out the thermal camera and immediately spotted the culprit: the IC responsible for transforming VBAT to VDD_MAIN was blazing hot. Watch the full microsoldering process as we remove the faulty chip, prep the pads, drop in a replacement, and bring this iPhone 13 Pro Max back to life!
#iPhone13ProMaxRepair #Microsoldering #ThermalCamera #AppleRepair #MotherboardRepair #VDDMAIN #TechRepair #ElectronicsRepair #RightToRepairHow to Fix iPad Air 5 Fast Battery Drain & Overheating (Logic Board Repair)BoardRev2026-05-07 | Is your iPad Air 5 battery draining incredibly fast while the back of the tablet gets super hot? You might not need a new battery!
In today's video, I tackle an iPad Air 5 that came in with severe battery drain and overheating issues. After carefully removing the display and the motherboard shield, thermal imaging (or freeze spray/rosin) revealed a pulsing, shorted capacitor on the logic board. Watch the step-by-step process as I diagnose the short, remove the faulty cap, solder on a replacement, and bring this iPad back to life perfectly!
If this video helped you understand what goes into board-level iPad repair, please hit that LIKE button and SUBSCRIBE for more deep-dive tech repairs! Let me know in the comments if you've ever dealt with a device getting this hot.
Disclaimer: This video is for educational purposes. Opening your iPad and performing board-level microsoldering carries a high risk of permanent damage. Proceed at your own risk.
#iPadRepair #Microsoldering #RightToRepair #iPadAir5 #LogicBoardRepairiPhone Tech Tries Android Repair With ZERO Experience! (Samsung A16)BoardRev2026-05-05 | I usually spend my days under the microscope repairing iPhone logic boards and MacBooks, but today I’m stepping into unfamiliar territory: my VERY FIRST Android motherboard repair!
I took in this Samsung Galaxy A16 4G with absolutely zero Android experience. It came in completely dead, pulling 0V on the charger. Watch me apply my Apple repair knowledge to an Android board, track down a dead VBUS line, find the shorted OVP chip using a thermal camera, and perform a bypass to bring this phone back to life.
In this video:
- The Crossover: Approaching an Android board as an Apple tech. - The Diagnosis: Diode mode testing and catching a 0V draw. - The Hunt: Using the thermal cam to spot the shorted OVP chip under the shield. - The Fix: Removing the IC and running a jumper wire to restore charging.
Turns out, a short circuit speaks the same language whether it's running iOS or Android!
#FirstAndroidRepair #Microsoldering #SamsungA16 #AppleTech #PhoneRepairDead iPhone 15 Pro Fix: Tracing a 2.5A Short & Hidden ACE FaultBoardRev2026-05-02 | In this video, we tackle a completely dead iPhone 15 Pro that came into the shop with no power and no ability to charge.
Upon connecting the board to the lab DC power supply, I immediately found a massive 2.5A instant current draw on the battery connector. Using the thermal camera, the heat led us straight to the bottom of the top board. After splitting the sandwich boards, the culprits were visible: a cracked charging IC and a cracked charging coil.
But the repair didn't stop there! After replacing the coil and removing the bad IC, a prompt-to-boot test revealed an abnormal over 200mA starting current (instead of the normal 60-90-120mA sequence). Experience told me this was a secondary fault with the ACE (USB-PD controller). Booting the phone confirmed this, as we had no touch functionality. Watch the full process as we replace the Charging IC, the ACE, and its ROM to bring this iPhone 15 Pro fully back to life!Warranty Denied for Vape Damage?! Lenovo Legion Pro 5 Repair Mystery (Part 1)BoardRev2026-05-01 | What happens when Lenovo denies your warranty because of "liquid damage due to vaping"? This Legion Pro 5 (Ryzen 7, RTX 4060) arrived at my bench completely dead after another shop gave up on it. In this video, we dive into the diagnostics, checking the 3V/5V lines, LDOs, and using the oscilloscope to find zero activity on the BIOS CS line.
After applying some liquid rosin and heat to the CPU to clear out any hidden residue from the previous shop, we got it booting perfectly! ...Or so we thought. Make sure to watch the intro, because this laptop has a mind of its own. Part 2 is coming next week as we tackle a returning Nvidia RTX 4060 error!Another Shop Missed This! iPhone 15 Pro Not Charging Fix (Oscilloscope Diagnosis)BoardRev2026-04-30 | Got an iPhone 15 Pro from another repair shop that was stuck at 5V, not charging, and showing a fake 1% battery. If you are dealing with a phone that auto-boots the second you connect the battery, this video is for you!
In this repair walkthrough, we dive deep into the diagnostic process. While diode mode on the battery connector's clock and data lines measured completely fine, hooking up the oscilloscope told a different story: a flat line at ~0.8V instead of the 1.8V pull-up with I2C traffic we expect to see.
Watch as we trace the issue down to the U4000 charging IC, split the sandwich board, replace the faulty chip, and restore full 9V PD fast-charging!Completely DEAD Asus Laptop! Quick 8-Minute Thermal Camera Fix (S330U)BoardRev2026-04-23 | In this quick 8-minute repair video, we tackle an Asus S330U laptop that is completely dead and unresponsive. When hooking it up to the bench power supply, you can actually hear the PSU clicking—a classic sign of a dead short on the motherboard.
Watch as we hook up the thermal camera, inject voltage into the main power line, and immediately spot the culprit: a glowing, shorted capacitor. Once the bad component is removed, the laptop fires right back up!
Tools used in this video: - Bench Power Supply - Thermal Camera
If you found this quick repair helpful, please hit the LIKE button and SUBSCRIBE for more electronics and laptop motherboard repairs!
#AsusRepair #LaptopRepair #MotherboardRepair #ThermalCamera #RightToRepair #TechRepair #ShortedCapacitorThis Acer was Cleaned to Death... then I fixed it.BoardRev2026-04-21 | -What happens when you mix an Acer Aspire 3 with a bottle of shampoo? You get a diagnostic nightmare.
In today’s video, we take on a "botched" repair from another shop. This laptop suffered extensive liquid damage that required more than just an ultrasonic cleaner. We dive deep into the power sequencing of the board, discovering why the 3V Always-On (ALW) rail was missing and how I "stole" an enable signal to move the diagnosis forward.
This isn't just a repair; it’s a full tutorial on using a multimeter, oscilloscope, and lab power supplies to trace faults back to the EC chip and CPU driver lines.
What you’ll learn in this video:
- How to perform a post-liquid damage visual inspection. - Repairing corroded pins on an EC (Embedded Controller) chip. - Isolating SMPS chips to verify functionality. - Understanding Enable (EN) signals and power rail sequencing. - Finding tiny corroded resistors that halt the entire CPU boot process.
Tools used in this repair:
- Oscilloscope (Signal tracing) - Dual Lab Power Supplies - Multimeter - Microscope for micro-solderingiPhone 15 Pro Max Turns On But NO DISPLAY? (Common Short Fixed!)BoardRev2026-04-19 | Got an iPhone 15 Pro Max that boots up perfectly on the power supply but has a completely black screen? You're not alone. This is an incredibly common issue with this series, and today, I'll walk you through the exact diagnostic steps to fix it.
In this video, we tackle a textbook case of a shorted PNVAR_DISPLAY_VSSEL line. Watch the full microsoldering process as we diagnose the issue, split the boards, and use voltage injection with a thermal camera to pinpoint the exact culprit.
1. Verifying proper boot sequence using a DC power supply. 2. Diode mode measurements on the display connector to confirm the short. 3. Splitting the logic board. 4. Injecting 0.8V onto the shorted line. 5. Using a thermal camera to locate the glowing shorted capacitor (C9436). 6. Removing the short and restoring the image!
If this video helped you fix a board or understand the process better, please hit that LIKE button and SUBSCRIBE for more deep-dive motherboard repairs! Drop a comment below if you've run into this specific C9436 short before.
#iPhone15ProMax #Microsoldering #MotherboardRepair #ThermalCamera #RightToRepairBotched Repair FIXED! Lenovo Legion Power Button Nightmare 🛠️BoardRev2026-04-03 | In today's video, we tackle a mystery Lenovo Legion laptop (missing its bottom plate!) that came in from another repair shop. It originally had a broken power button, but the previous shop’s attempt to fix the existing button made things worse.
The laptop would only turn on after a BIOS reset, and even then, it would completely freeze at the Legion logo or during Windows startup—a classic symptom of a malfunctioning power button sending erratic signals to the board!
What we cover in this repair:
Diagnosing the boot freeze issue and tracing it to the botched power button.
Cleaning up the previous repair shop's messy soldering job.
Scavenging a replacement button from a donor board.
Modifying and trimming the laptop's plastic button cap to perfectly fit the slightly taller replacement switch.
Testing and successful Windows boot!
If you enjoy component-level repairs and fixing botched jobs, make sure to hit that Like button and Subscribe for more!Dead iPad Pro M2 (A2436) USB-C Repair | Custom Soldering to Save the Day!BoardRev2026-03-31 | This iPad Pro A2436 (M2) came into the shop completely dead and refusing to charge. The culprit? A heavily corroded USB-C charging port.
Ordering a new charging flex for this specific model would have left the customer waiting for at least 5 days. To get them back up and running immediately, I had to get creative. In this video, I take you through the microsoldering process of desoldering a healthy USB-C connector from an older iPad Pro 2020 (4th Gen) replacement flex, and successfully grafting it onto the original flex of this newer M2 iPad Pro. It booted right up and charged perfectly!
If you enjoy microsoldering repairs and out-of-the-box tech solutions, make sure to hit that subscribe button! Leave a comment if you've ever had to do a "Frankenstein" repair to save a customer time.
Need a repair? Contact me here: service@aacservices.ro
#iPadRepair #Microsoldering #RightToRepair #iPadProA2436 #AppleRepair #TechRepair #Soldering #USBCRepair #iPadProM2 #LogicBoardRepairMacBook Pro M3 Dead (5V 20mA) - How a Tiny Capacitor Killed a Coil!BoardRev2026-03-30 | In today's video, we tackle a dead MacBook Pro M3 (Model A2918) that isn't pulling more than 5V at 20mA. If you’ve ever seen a 5V "stuck" state on a USB-C meter, you know it's often a missing power rail or a communication issue.
The Diagnostic Process:
Initial Check: Diode mode readings on PPBUS_AON and PP3V3_AON were normal.
The Discovery: Found liquid damage/corrosion on PP5V_SPMU_BSTLQ_XW causing a hard short.
The Twist: Removing the shorted capacitors didn't fix it!
The Solution: Traced the line back to the PMIC and found a blown inductor on the SPMU_BSTLQ_LX line. A quick swap with a donor coil from an iPad (shoutout to cross-compatibility!) brought this M3 back to life.
#MacBookRepair #M3MacBookPro #Microsoldering #RightToRepair #LogicBoardRepairIm Done Fixing iPhone boards. Heres Why.BoardRev2026-03-26 | In today's video, we need to have an honest talk about the future of phone motherboard repairs on this channel.
After a lot of thought, I’ve decided to step back from offering general phone board repairs. The reality is that 99% of the phones I receive have suffered severe physical damage (heavy drops, impacts, etc.). Because of this underlying trauma, it is incredibly difficult to confidently warranty the repair. When you add in the massive amount of time it takes to properly separate, diagnose, and rebuild modern double-layered iPhone boards, the math just doesn't work out anymore. It is simply not economically feasible for my business.
What does this mean for the channel? I am NOT stopping repairs entirely! However, moving forward, I will only be taking in phone board repairs if the diagnosis is unique, interesting, or provides great educational value for a video. I want to focus my time on content that teaches and challenges us, rather than fighting endless battles against drop-damaged sandwich boards.
Thank you all for your continuous support and understanding as I make this transition to keep the business healthy and the channel interesting! Let me know your thoughts in the comments below.
#Microsoldering #RightToRepair #PhoneRepair #MotherboardRepair #TechBusinessMacBook Pro 16 Tricked Me! DFU Revive & The Devious Leaky CapBoardRev2026-03-26 | Today we are repairing a dead MacBook Pro 16" (A2141, 2019). The symptoms were tricky: 20V negotiation, but the fans would only spin for about 3 seconds before shutting off. The logic board was incredibly dusty, but the main power rails (PPBUS_G3H and NAND voltages) looked OK. This repair really threw me off at first. I was able to force the board into DFU mode using a host Mac and Apple Configurator. A successful Revive seemed to fix the fan loop, and the board powered on (we even got a Caps Lock light toggle!), but there was absolutely no image and $0\text{V}$ on the CPU coils. With the T2 chip initialized but no image, I moved to the backlight circuit (PPVOUT_S0_LCDBKLT). This is where the real fault was hidden. A deivous, "leaky" ceramic capacitor (C8463) was only partially shorted. In Diode Mode, the line measured 0.181V instead of the expected 1.181V. This leak was just enough to prevent the backlight driver (U8400) from boosting voltage to the screen. We locate the faulty high-voltage cap under the microscope, replace it, and restore the 1.181V reading. Watch until the end to see the full reassembly and successful boot!
#MacBookRepair #A2141Repair #DFURevive #BacklightShort #MicroSoldering #AppleConfiguratoriPhone 14 Pro Stuck in DFU: Tracking Down a Hidden NAND FaultBoardRev2026-03-17 | In today’s video, we tackle an interesting data recovery case: an iPhone 14 Pro stuck in DFU mode. This device came to us from another repair shop. After an attempt to fix a cellular reception issue by splitting the sandwiched logic boards, the top board completely died and refused to boot past DFU.
Follow along as we walk through the diagnostic process to find the true culprit and save the customer's data!
🔬 What we cover in this repair:
The Initial Triage: Verifying the DFU state in 3uTools. Because the exact device model was correctly identified, we immediately ruled out missing or damaged Board ID resistors.
Power Rail Diagnostics: Booting the top board via PSU and using an oscilloscope to verify the NAND power lines (PP1V24_S0, PP0V83_NAND_S0, and PP2V625_NAND_S0). All power lines were clean and stable.
Finding the Fault: Moving to the PCIe communication lines (TX-, TX+, RX-, RX+). By measuring diode mode values at the series capacitors, we found healthy readings on the CPU side, but a dead Open Loop (OL) on the NAND side.
The Fix: A physical disconnect! We removed the NAND chip, cleaned the pads, reballed it, and dropped it back onto the board for a successful boot and full data recovery.
Don't forget to like, subscribe, and leave a comment if you want to see more board-level diagnostics and micro-soldering repairs!
#iPhone14Pro #Microsoldering #DataRecovery #DFUMode #LogicBoardRepair #NANDReball #TechRepairA Tiny Chip Killed This MacBook Pro (and its Data)BoardRev2026-03-16 | We have an Apple MacBook Pro A1990 on the bench today. The symptom is a classic one: it's stuck looping at 5 Volts on the USB-C amp meter.
My initial troubleshooting led me to a low diode mode value on the main power rail, PPBUS_G3H. This frequently points to corrosion on the U9580 SSD power management IC, a common fault on this model due to its proximity to the vents.
However, upon lifting the chip, we found no liquid damage. Instead, the real nightmare was revealed: U9580 had failed internally, dead-shorting the main system voltage (12.6V) directly into the 2.5V NAND data line. The diagnostic trace shows not only a dead power IC but total destruction of both associated SSD NAND chips—one even has a visible burn hole inside.
This video is a "forensic autopsy" of a logic board, demonstrating exactly how a failure in a small, $5 component can cause catastrophic, unrecoverable data loss and render a high-end machine beyond practical repair.
#MacBookRepair #A1990 #DataLoss #MicroSoldering #Apple #ElectronicsRepairWhy Wireless Charging Clues Saved This iPhone 14 Pro Repair!BoardRev2026-03-11 | iPhone 14 Pro not charging? Don't replace Kraken just yet!
In today's masterclass, we diagnose an iPhone 14 Pro that is completely "dead" on the USB meter, drawing only 0.001mA at 5V. While the lack of CC line activity on the oscilloscope initially suggested a Kraken (USB controller) failure, a quick test of the wireless charging circuit changed the entire diagnostic path.
In this video, you will learn: - How to use an oscilloscope to check for CC line/PD negotiation. - Why wireless charging failure points directly to the Tigris Charging IC. - How to split the iPhone 14 Pro sandwich boards for troubleshooting. - Identifying a short on the PP_VAR_USB_RVP line in Diode Mode. - The step-by-step replacement of the Tigris IC and final verification.