Liquid crystal elastomer (LCE) is a promising material to develop thermally-driven soft actuators due to its high force density, large elastic strain limits, and mechanically programmable nature. However, the bandwidth of these actuators is typically well below 1 Hz, therefore limiting their potential use cases. In this work, we developed a new thermally driven soft actuator that consists of several LCE units bundled together with integrated cooling in order to achieve both high forces and bandwidths over 1 Hz. We also developed an electro-thermo-mechanical model and established design guidelines for developing our actuators for future soft robotic applications at the mesoscale.
Check out the video below where we used our actuator and design guidelines to develop an inchworm inspired crawling robot (capable of achieving speeds over 6 body lengths per minute) and a textile forearm cuff capable of generating varying levels of skin stretch for cutaneous haptic feedback.
Authors: Anoush Sepehri, Sukjun Kim, Devyansh Agrawal, Hannah Yared, Gaoweiang Dong, Shengqiang Cai, and Tania Morimoto
Liquid crystal elastomer (LCE) is a promising material to develop thermally-driven soft actuators due to its high force density, large elastic strain limits, and mechanically programmable nature. However, the bandwidth of these actuators is typically well below 1 Hz, therefore limiting their potential use cases. In this work, we developed a new thermally driven soft actuator that consists of several LCE units bundled together with integrated cooling in order to achieve both high forces and bandwidths over 1 Hz. We also developed an electro-thermo-mechanical model and established design guidelines for developing our actuators for future soft robotic applications at the mesoscale.
Check out the video below where we used our actuator and design guidelines to develop an inchworm inspired crawling robot (capable of achieving speeds over 6 body lengths per minute) and a textile forearm cuff capable of generating varying levels of skin stretch for cutaneous haptic feedback.
Soft everting robots grow their body from the tip via eversion, enabling minimal interaction with their surroundings. They can traverse complex environments by changing the growth direction via integrated steering mechanisms. However, it is challenging to miniaturize existing steering mechanisms and to achieve multiple bends while remaining fully soft. In this work, we present an approach to create millimeter-scale, steerable, and fully soft everting robots by functionalizing the robot skin with liquid crystal elastomer (LCE) actuators. This design enables large bending angles (greater than 100°) at multiple points along the robot’s length. We investigate the effects of internal pressure and actuator temperature as control inputs for steering and demonstrate the potential of our design for practical applications, such as surgical procedures and inspection tasks. Our results highlight the advantages of soft, functionalized skins and represent a step toward small, steerable, soft everting robots for applications in delicate and constrained environments.
Stroke is a leading cause of death and disability - two of the hardest challenges in treating ischemic stroke are: navigating around the aortic arch (particularly type III) and traversing tortuous internal carotid arteries. We developed a robotic system that tackles both using two soft robots working together. In the video, you’ll see: System architecture: a soft notched continuum robot that deploys a soft growing robot from its tip Control interface: a gamepad enabling intuitive control in both joint space and task space Deployment demo: a full system run in a benchtop anatomical model that includes a type III aortic arch and a highly tortuous internal carotid artery
Authors: Aedan Mangan, Sukjun Kim, Noah Jones, Michael G. Brandel, Jeremy J. Heit, Alexander Norbash, John T. Hwang, Elliot Hawkes, and Tania K. Morimoto
Abstract: Concentric tube robots (CTRs) are miniaturized continuum robots that are promising for robotic minimally invasive surgeries. Control methods to date have primarily focused on controlling the robot tip. However, small changes in the tip position can result in large deviations in the shape of the robot body, motivating the need for shape control to ensure safe navigation in constrained environments. One proposed method for shape control, known as follow-the-leader (FTL) motion, allows the robot to deploy while occupying minimal volume but is limited to specific CTR designs and deployment sequences. In this letter, we propose a shape control method that approximates FTL motion and is applicable to arbitrary tip navigation tasks without requiring a predefined trajectory or specific tube design. This shape control method is framed as a nonlinear optimization problem, and through linearization of the CTR's kinematics, we turn it into a quadratic program solved by a shape controller that requires minimal knowledge of the robot's shape. Simulations show that our method enables better approximate FTL motion compared to a state-of-the-art Jacobian-based tip controller across different tube sets and tip paths while remaining computationally comparable. Furthermore, a hardware demonstration validates the effectiveness of the shape controller on a physical system during teleoperation.
Authors: Yunti (Anna) Xu, Connor Watson, Jui-Te Lin, John T. Hwang, and Tania K. MorimotoKinked Air Channel Enables Retraction of Small-Scale Soft Everting RobotsUCSD Morimoto Lab2025-04-18 | Retraction of soft everting robots via material inversion enables minimal interaction between the robot and the environment, as well as repeated growth and retraction for navigating through complex paths. However, existing retraction strategies are limited to larger-scale robots and often require integration of rigid components. In this work, we present a retraction mechanism for millimeter-scale, soft everting robots enabled by a kinked air channel. The flat air channel is attached to the robot body and kinked at the tip. This kink blocks the air flowing through the channel, allowing the pressure to effectively apply a retraction force at the tip for buckling-free retraction. We developed and validated a model by characterizing the robot at various scales and studying the effectiveness of the kinked air channel for retraction. We demonstrated the robot’s retraction capability in several challenging environments, highlighting the benefits of the small size and softness of the retraction mechanism.
Music by: bensound.com/free-music-for-videos License code: J0ENNJDYNWFYVNGGHCR: Haptic Continuum Robot for Multi-Modal Cutaneous FeedbackUCSD Morimoto Lab2025-04-18 | Cutaneous haptic feedback provides a sense of touch by displaying sensations — such as vibration, skin stretch, or normal force — directly to the skin. While the majority of these devices have been designed to display one main haptic sensation, recent work has begun to explore the creation of multi-modal haptic devices, capable of rendering a variety of cutaneous cues. In this work, we investigate using the tip and body of a continuum robot to directly render multiple cutaneous cues to the fingerpad. We present the design of a device that consists of two Haptic Continuum Robots (HCRs) that is capable of rendering four distinct haptic cues— skin stretch, skin slip, normal indentation, and vibration. We present and validate a model of the proposed HCR and characterize the device performance. Finally, we conduct a preliminary haptic sensation identification study, which showed that users were able to correctly identify the displayed haptic sensation with 90% accuracy.
Authors: Fred Lin, Aedan Mangan, and Tania Morimoto
Full paper: ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=10910154InchIGRAB: An Inchworm-Inspired Guided Retraction and Bending Device for Vine RobotsUCSD Morimoto Lab2025-04-18 | Title: InchIGRAB: An Inchworm-Inspired Guided Retraction and Bending Device for Vine Robots During Colonoscopy
Vine robots are soft robots that translate by everting, or growing, from their tips. This mechanism of translation minimizes the application of shear forces on the environment, making them particularly well-suited for surgical tasks, such as colonoscopy. However, steering and retracting vine robots within tortuous and delicate environments presents significant challenges. In this article, we introduce a novel soft robotic system for colonoscopy that consists of an inchworm-inspired device—the InchIGRAB—nested within a vine robot. The InchIGRAB is designed to enable steering of the vine robot along curved paths, as well as to enable controlled retraction of the vine robot after it reaches its target. We present the design, modeling, and fabrication of the robotic system and characterize its performance. Furthermore, we demonstrate the presented robotic system's ability to safely navigate the entire colon length, including several curved sections, during both forward motion and retraction, highlighting its potential as a robotic colonoscope that offers enhanced safety for patients.
Authors: Ayush Giri, Cédric Girerd, Jacobo Cervera-Torralba, Michael T. Tolley, and Tania K. Morimoto
Full paper: ieeexplore.ieee.org/abstract/document/10910211PneuSIC Box: Pneumatic Sequential and Independent Control Box for Scalable DemultiplexingUCSD Morimoto Lab2025-04-18 | Soft robots are well suited for various applications, including wearable robotics, haptic devices, and medical robotics, due to their inherent compliance. While there are many methods for actuating soft robots, pneumatic actuation remains the dominant choice because it enables large force output and a fast response time. However, actuating a robot with multiple independent pneumatic actuators requires an equal number of pressure regulators and associated electromechanical components, making the back-end control setup bulky, expensive, and unsuitable for potential untethered applications. In this work, we present PneuSIC Box, a pneumatic demultiplexer inspired by the working principle of a music box. Unlike other pneumatic demultiplexing methods that require many pneumatic and control inputs based on the number of actuators, PneuSIC Box operates with just a single pneumatic input and a motor. Furthermore, PneuSIC Box enables simultaneous control of multiple actuators and allows pneumatic memory retention in the attached actuators without any energy expenditure due to the use of soft kink valves. We discuss the working principle and design of the device, provide a finite element analysis (FEA) model to aid in the design of the kink valves, and present detailed device characterization. Finally, we demonstrate the device's applicability using an inchworm-like robot and a robotic hand with soft fingers.
Authors: Ayush Giri, Alvaro M. Rivas, Ram Hemanth Yeerella, Shengqiang Cai, and Tania K. Morimoto